Product Description
The B&R 8BVP1650HW00.000-1 ACOPOSmulti Power Supply Module is a high-capacity power supply and regenerative unit designed for industrial multi-axis servo drive systems. Rated at 165 A, this wall-mounted module supports a three-phase input voltage range of 220–480 VAC and delivers a nominal DC bus voltage of 750 VDC. It provides up to 120 kW continuous power and 240 kW peak power for demanding motion control applications. Its regenerative capability allows braking energy to be returned to the power supply system, while the integrated power factor correction, temperature sensor connection, and two plug-in module slots support flexible system integration. It is suitable for industrial machinery, automated production lines, packaging equipment, and multi-axis motion control installations. This unit is listed in Mint Condition and is intended for replacement, maintenance, or expansion of compatible B&R ACOPOSmulti installations.

📋 Product Datasheet – Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | B&R Industrial Automation |
| Model | 8BVP1650HW00.000-1 |
| Series | ACOPOSmulti |
| Product Name | Power Supply Module, 165 A |
| Place of Manufacture | Austria (Brand Headquarters); actual manufacturing site unconfirmed |
| Product Status | Mint Condition – Seller Listed |
| Dimensions | 427.5 × 317 × 263 mm (W × H × D) |
| Weight | 26 kg |
| Country of Origin | Not confirmed |
| Power Requirements | 3 × 220–480 VAC ±10%, 50/60 Hz ±4%; 750 VDC nominal DC bus |
| Continuous / Peak Power | 120 kW / 240 kW |
| Discontinued | Not confirmed; listed in B&R product documentation |
⚙️ Key Technical Features
- Rated current: 165 A (model designation).
- Regenerative power conversion.
- Maximum continuous power: 120 kW.
- Maximum peak power: 240 kW.
- Nominal DC bus voltage: 750 VDC.
- Maximum installed load: 124 kW.
- Power factor correction (PFC).
- Two plug-in module slots.
- Wall-mounted installation design.
- Integrated temperature sensor connection.
- DC bus capacitance: 3,630 µF.
- Protection rating: IP20.
- Permissible ambient operating temperature: 5–40°C nominal, 55°C maximum.
🏭 Application Scenarios & Industrial Uses
- Multi-axis servo drive systems in automated manufacturing.
- Packaging and material handling machinery.
- High-speed production and assembly equipment.
- Industrial printing and converting machines.
- CNC machinery and synchronized motion systems.
- Regenerative braking applications.
- Industrial automation system upgrades and replacement projects.
🔧 Operating Instructions & Usage Guidelines
1. Installation and Preparation
- Verify that the model number matches the original equipment specification.
- Check the mounting structure and required ventilation clearance.
- Install the module in the approved vertical hanging or horizontal face-up orientation.
- Verify the three-phase input supply, protective earth, and DC bus connections.
- Check the required terminal block accessories and cable specifications.
- Confirm that the connected ACOPOSmulti modules are compatible.
- Ensure that all wiring is completed by qualified electrical personnel.
2. Power-On Sequence
Step 1: Inspect the module, electrical connections, grounding, and cabinet ventilation.
Step 2: Confirm that all servo drives and connected machinery are in a safe, disabled condition.
Step 3: Verify the three-phase AC input voltage and phase connections.
Step 4: Energize the upstream supply and associated protective equipment according to the approved electrical design.
Step 5: Allow the power supply module to complete its startup and DC bus charging process.
Step 6: Check the module status and verify that no power supply or communication faults are present.
Step 7: Enable the motion control system through the configured controller and drive sequence.
Step 8: Test the system at low load before returning the machinery to normal production.
3. Normal Operating Procedure
- Monitor DC bus voltage and power supply status.
- Check the operating temperature and cooling airflow.
- Monitor connected servo drives for alarms and abnormal operating conditions.
- Verify that regenerative operation is functioning within the system design limits.
- Avoid exceeding the rated continuous power.
- Record abnormal alarms and operating conditions for maintenance purposes.
4. Parameter Configuration and Modification
- Use the appropriate B&R Automation Studio engineering environment and compatible ACOPOSmulti configuration tools.
- Open the existing machine project and identify the installed power supply module.
- Verify hardware identification and the applicable firmware and software versions.
- Review the DC bus configuration, connected drive modules, power limits, and protection settings.
- Modify only parameters supported by the installed hardware and software configuration.
- Save and validate the engineering project before downloading approved changes.
- Perform a controlled restart and verify the system status.
Parameter names, available settings, and configuration procedures depend on the installed hardware and software versions. Do not change electrical protection limits without engineering approval.
5. Shutdown Sequence
Step 1: Stop the machine through the normal control interface.
Step 2: Command all connected servo axes to decelerate to a complete stop.
Step 3: Disable servo drive operation and remove motion enable signals.
Step 4: Confirm that regenerative braking and motor movement have stopped.
Step 5: Switch off the upstream AC supply according to the machine shutdown procedure.
Step 6: Apply lockout/tagout procedures before electrical maintenance.
Step 7: Wait for the DC bus to discharge and verify the absence of hazardous voltage using an appropriately rated measuring instrument before touching electrical connections.
Warning: The DC bus can retain dangerous electrical energy after the input supply is disconnected. Never rely solely on indicator lights to confirm that the module is safe.
🛠️ Daily Maintenance & Troubleshooting
Daily Maintenance
- Inspect the module for dust accumulation and physical damage.
- Check cabinet ventilation and cooling fan operation.
- Inspect power terminals for signs of overheating.
- Monitor system alarms and operating temperatures.
- Check protective earth connections.
- Keep the electrical cabinet clean and dry.
Common Troubleshooting
- No power-up: Check three-phase input voltage, upstream fuses, and electrical connections.
- DC bus undervoltage: Verify the AC supply, charging process, and connected DC bus load.
- Overtemperature: Inspect cooling airflow, cabinet temperature, and fan operation.
- Unexpected drive faults: Check DC bus stability, connected inverter modules, and system configuration.
- Regenerative power problems: Verify the regeneration path, power limits, and system electrical design.
⚠️ Safety Precautions
- Installation and maintenance must be performed by qualified personnel.
- Disconnect all relevant power sources before electrical work.
- Follow the manufacturer’s discharge waiting and voltage verification procedures.
- Never exceed the specified input voltage or power ratings.
- Maintain correct grounding and protective device coordination.
- Do not operate the module with damaged terminals or cooling components.
- Use only approved replacement accessories and compatible system components.
🔗 Product & Industrial Automation Resource
For additional industrial automation products, replacement modules, and spare parts, visit B&R ACOPOSmulti Automation Modules.
📦 Recommended B&R Related Models – 15 Products
- B&R 8BVP0220HW00.000-1 – ACOPOSmulti Power Supply Module
- B&R 8BVP0440HW00.000-1 – ACOPOSmulti Power Supply Module
- B&R 8BVP0880HW00.000-1 – ACOPOSmulti Power Supply Module
- B&R 8BVI0014HWS0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVI0028HWS0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVI0055HWS0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVI0110HWS0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVI0220HWD0.000-1 – ACOPOSmulti Inverter Module
- B&R 8B0C0160HW00.000-1 – ACOPOSmulti Auxiliary Supply Module
- B&R 8BVE0500HW00.000-1 – ACOPOSmulti Expansion Module
- B&R 8BVF0880H000.000-1 – ACOPOSmulti Line Filter
- B&R 8BAC0120.000-1 – ACOPOSmulti EnDat 2.1 Interface Module
- B&R 8BAC0121.000-1 – ACOPOSmulti HIPERFACE Interface Module
- B&R 8BXF001.0000-00 – ACOPOSmulti Replacement Fan Module
- B&R 8BZVP165000.000-1A – ACOPOSmulti Terminal Block Set
Note: Related models are not automatically interchangeable. Verify electrical ratings, mounting type, firmware compatibility, accessories, and system configuration before ordering.