Product Description
The B&R 8I74T400400.010-1 is an ACOPOSinverter P74 variable frequency drive designed to control three-phase AC motors in industrial automation systems. Rated for 4 kW motor applications, it accepts a three-phase 380–500 V AC supply and provides adjustable motor speed and frequency control. The unit features an integrated EMC filter and brake chopper, supporting applications that require controlled motor deceleration and electrical noise management. It is suitable for integration into machinery, production equipment, and automated material-handling systems. Before installation, verify the exact order code, motor nameplate data, control interface, and system configuration.

Key Product Parameters
- Brand: B&R
- Model: 8I74T400400.010-1
- Series: ACOPOSinverter P74
- Product Name: Variable Frequency Drive / Inverter
- Rated Motor Power: 4 kW (5 HP)
- Input Voltage: 3-phase 380–500 V AC
- Input Frequency: 50–60 Hz ±5%
- Mains Current: 13.7 A at 380 V AC / 10.5 A at 500 V AC
- Apparent Power: 9.1 kVA at 500 V AC
- Integrated Features: EMC filter and brake chopper
- Dimensions: 60 × 317 × 245 mm
- Weight: Approximately 2.176 kg
- Protection Rating: IP20
- Product Status: New
- Country of Origin: Not confirmed; check the product label
- Power Requirements: Three-phase 380–500 V AC supply
- Discontinued Status: Confirm with B&R for the exact revision
Installation and Operating Procedures
- Preparation
- Confirm the inverter model and revision against the machine electrical drawings.
- Check the motor rated voltage, current, power, frequency, and connection configuration.
- Inspect the inverter housing, terminals, cooling openings, and included accessories.
- Verify that the cabinet provides adequate ventilation and meets the installation requirements.
- Installation
- Mount the inverter vertically in a suitable electrical cabinet.
- Maintain the specified ventilation clearances and avoid obstructing cooling airflow.
- Connect the protective earth conductor before connecting power wiring.
- Connect the three-phase supply and motor cables to the terminals identified in the B&R manual.
- Install shielded motor cable and connect cable shields according to the EMC installation instructions.
- Power-On Checks
- Verify supply voltage, grounding, terminal tightness, and motor wiring.
- Confirm that the motor and inverter ratings are compatible.
- Check the braking circuit and any external braking resistor requirements.
- Apply power only after the installation has passed electrical safety checks.
- Configuration
- Enter the motor nameplate parameters, including rated voltage, current, frequency, and speed.
- Configure acceleration and deceleration ramps, operating limits, and protection functions.
- Set the required command and reference sources according to the machine control architecture.
- Verify communication and control settings where the application uses a fieldbus or external controller.
- Normal Operation
- Test motor rotation at low speed before commissioning the full machine.
- Check current, operating frequency, motor temperature, and acceleration behavior.
- Confirm that stop commands, interlocks, and fault responses operate correctly.
- Record the final parameter settings for maintenance and future replacement.
- Shutdown
- Stop the motor using the configured control sequence.
- Isolate the mains supply before electrical maintenance.
- Wait for the DC bus capacitors to discharge and verify the absence of hazardous voltage before touching terminals.
Daily Maintenance
- Check the inverter for abnormal noise, vibration, or overheating.
- Keep cooling openings and cabinet ventilation paths free from dust.
- Inspect power terminals, grounding connections, and cable insulation.
- Monitor operating current and fault history for unusual changes.
- Check the condition of cooling fans and replace them when required.
- Review cabinet temperature and ventilation performance.
- Back up drive parameters after commissioning or approved configuration changes.
Troubleshooting
- No power or display: Check the incoming three-phase supply, protective devices, and wiring connections.
- Motor does not run: Verify enable signals, run commands, interlocks, and motor connections.
- Overcurrent fault: Check for motor cable short circuits, mechanical overload, incorrect motor parameters, or excessively short acceleration times.
- Overvoltage during deceleration: Review the deceleration ramp and braking circuit configuration.
- Motor overheating: Check motor load, cooling, operating frequency, and rated motor parameters.
- Communication failure: Verify the installed interface, network wiring, controller configuration, and communication settings.
- Excessive electrical noise: Inspect cable shielding, grounding, cable routing, and EMC installation practices.
Safety Precautions
- Installation and commissioning must be performed by qualified electrical personnel.
- Disconnect and lock out the power supply before wiring or maintenance.
- Allow the DC bus capacitors to discharge and verify the voltage with an appropriate measuring instrument.
- Never connect or disconnect motor cables while the inverter is energized.
- Ensure correct protective grounding and suitable upstream circuit protection.
- Do not exceed the rated voltage, current, or power limits.
- Follow the B&R ACOPOSinverter P74 installation and operating manual.
- Do not operate the inverter in environments outside its specified temperature, humidity, or protection limits.
Product Keywords
B&R 8I74T400400.010-1, ACOPOSinverter P74, B&R frequency inverter, 4 kW variable frequency drive, industrial motor drive, three-phase inverter, 380–500 V AC drive, EMC filter inverter, brake chopper drive, industrial automation spare parts, B&R ACOPOS drive.
For more industrial automation products and replacement components, visit www.newplcdcs.com.
15 Related / Recommended Models
The following are related B&R drive models and product references for comparison or system research. They are not confirmed drop-in replacements for 8I74T400400.010-1.
- B&R 8I74T400150.00-000 – ACOPOSinverter P74, 1.5 kW
- B&R 8I74T400220.00-000 – ACOPOSinverter P74, 2.2 kW
- B&R 8I74T400300.00-000 – ACOPOSinverter P74, 3 kW
- B&R 8I74T400400.00-000 – ACOPOSinverter P74new, 4 kW
- B&R 8I74T400400.01P-1 – ACOPOSinverter P74, 4 kW, POWERLINK interface
- B&R ACOPOSinverter P66 – Compact inverter series
- B&R ACOPOSinverter P74 – Variable frequency drive series
- B&R ACOPOSinverter P76 – Variable frequency drive series
- B&R 8I0XF074.020-1 – ACOPOSinverter cooling fan
- B&R 8I0FT025.200-1 – Additional EMC input filter
- B&R 8I0CT010.000-1 – Three-phase mains choke
- B&R 8I0IF108.400-1 – POWERLINK interface-related hardware reference
- B&R ACOPOSmulti – Modular drive system
- B&R ACOPOS P3 – Servo drive system
- B&R ACOPOS – Servo drive family