Product Description
The GENERAL ELECTRIC DS2020LPPA341A is a Line Protection Module designed for GE industrial drive and power-conversion equipment. Part of the DS2020 LPPA family used with GE Mark V-related power equipment, it provides line-side electrical protection and monitoring functions, including current-limiting fuse protection, voltage surge protection, and ground-current sensing. The module incorporates a DS200LPPA circuit board and is configured with three 30 A, 600 V DC fuses, four metal-oxide varistors (MOVs), and three grounding resistors. Its circuit board includes jumper links and terminal connections for protection and diagnostic functions. The DS2020LPPA341A is intended for use in the specified GE power-system assembly and should only be replaced with a module whose complete catalog number and electrical configuration match the original equipment.

Product Datasheet
- Brand: General Electric (GE)
- Model: DS2020LPPA341A
- Series: DS2020 LPPA / Mark V power equipment
- Product Name: Line Protection Module
- Functional Acronym: LPPA
- Module Type: Line Protection Panel Module
- Fuse Configuration: 3 × 30 A, 600 V DC
- MOV Configuration: 4 × 40 mm MOVs
- Grounding Resistors: 3 × 22 kΩ, 40 W
- Circuit Board: DS200LPPA
- Board Features: 7 jumpers, JP1–JP7, terminal blocks, and test points
- Main Board Connector: 40-pin ribbon-cable connector
- Terminal Blocks: 2 blocks, 3 terminals each
- Board Dimensions: Approximately 3.5 × 7 inches
- Module Weight: Not independently verified; supplier listings differ
- Place of Manufacture: Not verified
- Country of Origin: Not verified
- Product Status: Legacy GE power-system component
- Power Requirements: Control-board supply from the associated drive equipment; DS200LPPA connections include +24 V DC, ACOM, and -24 V DC
- Discontinued: Current OEM lifecycle status not independently confirmed
- Condition: Subject to seller confirmation
Operating Guidelines and Usage
1. Application and Compatibility
- Confirm that the host equipment is designed for the DS2020LPPA line protection module.
- Verify the complete module number, including the 341A configuration.
- Check the associated DS200LPPA board and the specified fuse, MOV, and grounding-resistor arrangement.
- Confirm that the module is installed in the correct position within the drive or power-conversion assembly.
- Do not substitute an LPPA, LPPB, or LPPC module solely because the product family designation is similar.
2. Electrical Connections
- Connect the module ground terminal to the equipment grounding system.
- Verify the control-power connections at the DS200LPPA terminal block.
- Check the +24 V DC, ACOM, and -24 V DC connections against the applicable GE wiring diagram.
- Inspect the line-side connections, fuse holders, MOV connections, and grounding circuit.
- Preserve the original ribbon-cable routing and maintain adequate separation from heat-producing components.
3. Jumper Configuration
- Record the original positions of JP1 through JP7 before removing the module.
- Verify jumper settings against the GEH-6361 manual and the host equipment configuration.
- Check that the MOV and AC line-filter blown-fuse detection circuits are correctly configured.
- Confirm the ground-current sensing and SCR ripple-filter settings where applicable.
- Do not change jumper positions based on another LPPA revision without checking the correct documentation.
Power-On and Power-Off Sequence
Power-On
- Confirm that installation and wiring inspection are complete.
- Verify the module catalog number and the installed fuse, MOV, and resistor configuration.
- Check the equipment grounding connection and control-power wiring.
- Confirm that the ribbon cable is correctly seated and routed.
- Inspect the terminal blocks and jumper positions.
- Restore power in accordance with the host drive manufacturer’s startup procedure.
- Check the protection-module diagnostics and verify that no fuse or ground-current fault is indicated.
- Confirm that the associated drive system is ready before returning it to service.
Power-Off
- Follow the equipment shutdown procedure and notify the responsible operator.
- Isolate all relevant AC and DC power sources.
- Apply lockout/tagout and verify that stored energy has been discharged.
- Confirm the absence of hazardous voltage before touching terminals or components.
- Record jumper positions and cable routing before disconnecting the module.
- Remove the module using the approved maintenance procedure.
- Protect the removed assembly from moisture, dust, and electrostatic discharge.
Normal Operating Procedure
- Confirm that the host drive is operating within its approved electrical limits.
- Monitor the protection system for fuse-failure, surge-protection, and ground-current indications.
- Check the module’s ground connection and associated diagnostic signals during scheduled inspections.
- Investigate abnormal indications before restarting the associated power equipment.
- Check fuse continuity and MOV condition when a protection alarm occurs.
- Compare ground-current measurements with the equipment’s established baseline.
- Record protection events, maintenance actions, and replaced components.
- Return the system to service only after the protection circuit has passed the required checks.
Parameter Settings and Modification
The DS2020LPPA341A is a hardware-based protection module. Its configuration is determined by its component arrangement, jumper positions, and connections to the host equipment.
- Fuse Rating: The 341A configuration is associated with three 30 A, 600 V DC fuses.
- MOV Arrangement: Verify the specified four-MOV configuration and the correct voltage rating.
- Grounding Resistors: Confirm the three 22 kΩ, 40 W resistors are present and correctly connected.
- JP1–JP3: Coordinate MOV or AC line-filter blown-fuse detection with the three-phase AC voltage connections.
- JP6: Provides the SCR ripple-filter configuration for the ground-current sensing circuit.
- Control Power: Verify +24 V DC, ACOM, and -24 V DC connections at the DS200LPPA board.
- Grounding: Maintain the specified chassis and analog-ground connections.
Do not change fuse ratings, MOV specifications, grounding-resistor values, or jumper settings without the applicable GE documentation and engineering approval.
Maintenance and Troubleshooting
Routine Maintenance
- Inspect the module for discoloration, cracked components, damaged terminals, or signs of overheating.
- Check fuse continuity using an approved test procedure after isolating the equipment.
- Inspect MOVs for visible damage or evidence of surge stress.
- Verify the grounding connection and inspect the grounding-resistor circuit.
- Check the 40-pin ribbon connector for secure engagement and damaged contacts.
- Inspect JP1–JP7 and compare their positions with the approved configuration record.
- Keep the module clean and dry, and use ESD protection when handling the circuit board.
Common Troubleshooting
Problem: Blown-fuse indication
Check the relevant fuse, MOV or AC line-filter circuit, jumper configuration, and phase connections.
Problem: Repeated fuse failure
Investigate abnormal line voltage, downstream faults, short circuits, and incorrect fuse specifications before replacing the fuse.
Problem: Ground-current alarm
Inspect the grounding connection, grounding-resistor bridge, sensor wiring, and possible insulation faults in the associated equipment.
Problem: Incorrect ground-current measurement
Check the analog sensing connections, grounding reference, and JP6 ripple-filter configuration where applicable.
Problem: No control-board response
Verify the +24 V DC and -24 V DC supplies, ACOM connection, ribbon cable, and host equipment interface.
Problem: Intermittent protection indication
Inspect terminal tightness, connector condition, jumper seating, and signs of heat damage. Compare the wiring with the original equipment drawings.
Safety Precautions
- Installation and maintenance must be performed by qualified electrical and drive-system personnel.
- The module is part of a power-protection assembly and may be exposed to hazardous AC and DC voltages.
- Always isolate the equipment, apply lockout/tagout, and verify the absence of voltage before maintenance.
- Allow DC bus capacitors and other energy-storage components to discharge according to the manufacturer’s procedure.
- Never bypass fuse protection, MOV protection, or ground-fault monitoring to keep equipment running.
- Use only the specified fuse ratings and approved replacement components.
- Maintain the original grounding arrangement and jumper configuration.
- Perform the required protection checks before returning the equipment to operation.
Recommended GE Models
The following models are related GE DS2020 power-system modules or Mark V control-system components. They are not all direct replacements for the DS2020LPPA341A. Confirm electrical ratings, module configuration, and host-equipment compatibility before ordering.
- DS2020LPPA300A – LPPA Line Protection Module
- DS2020LPPA301A – LPPA Line Protection Module
- DS2020LPPA340A – LPPA Line Protection Module
- DS2020LPPB310A – LPPB Line Protection Module
- DS2020LPPB312A – LPPB Line Protection Module
- DS2020LPPB320A – LPPB Line Protection Panel Module
- DS2020LRPAG1 – Resolver Module
- DS2020PDMAG3 – Power Distribution Module
- DS2020PDMAG4 – Power Distribution Module
- DS2020PDMAG6 – Power Distribution Module
- DS2020FECNRX015A – Field Exciter Module
- DS2020FECNRX020A – Field Exciter Module
- DS2020FECNRX025A – Field Exciter Module
- DS2020SVSAG2 – Mounted Panel Module
- DS2020UCOCN1G1 – Turbine Management Panel