Product Description
The GENERAL ELECTRIC IC2820-C100M3 is an electromagnetic undervoltage relay designed for electrical protection and control applications. This model belongs to the GE IC2820 relay family and is identified as an undervoltage relay with a built-in diode, a 230 V AC coil, and one normally open (NO) and one normally closed (NC) contact. It is used in control circuits where a change or loss of control voltage must trigger a defined relay response. The device can be applied in industrial power distribution, motor control, and electrical switchgear systems when its coil voltage, contact arrangement, and operating characteristics match the circuit design. Confirm the complete model number and terminal diagram before installation or replacement.

Product Datasheet
- Brand: General Electric (GE)
- Model: IC2820-C100M3
- Series: IC2820
- Product Name: Undervoltage Relay with Diode
- Relay Function: Undervoltage detection and switching
- Coil Voltage: 230 V AC
- Contact Configuration: 1 NO / 1 NC
- Built-in Component: Diode
- Contact Type: Electromechanical
- Application: Electrical control and protection circuits
- Mounting: Verify from the original relay and equipment drawings
- Dimensions: Not independently verified
- Weight: Approximately 2.15 kg (supplier-listed; confirm before shipping)
- Place of Manufacture: Not verified
- Country of Origin: Not verified
- Product Status: Legacy GE relay; current OEM lifecycle status not confirmed
- Power Requirements: 230 V AC relay coil; confirm frequency and coil ratings from the nameplate
- Discontinued: Not confirmed
- Condition: Subject to seller confirmation
Operating Guidelines and Usage
1. Application Compatibility
- Confirm that the control circuit is designed for a 230 V AC relay coil.
- Verify the undervoltage relay’s intended role in the equipment protection or interlocking scheme.
- Check the contact arrangement against the control schematic.
- Confirm the relay’s electrical and mechanical compatibility with the existing mounting and wiring arrangement.
2. Wiring and Connections
- Identify the coil terminals and NO/NC contact terminals from the relay’s original wiring diagram.
- Verify the supply voltage and frequency before energizing the coil.
- Check the built-in diode orientation and terminal requirements.
- Inspect wiring insulation, terminal tightness, and contact condition.
- Do not rely on terminal positions from a visually similar IC2820 model.
3. Installation
- Isolate the control circuit before removing or installing the relay.
- Record the original wiring and terminal assignments.
- Secure the relay in its designated mounting position.
- Check that no conductor is trapped or exposed.
- Perform continuity and insulation checks as required by the equipment manufacturer’s procedure.
Power-On and Power-Off Sequence
Power-On
- Confirm that the relay model and coil rating match the control circuit.
- Inspect the relay housing, terminals, and contact connections.
- Verify the 230 V AC supply and wiring polarity requirements for the diode-equipped design.
- Confirm that the NO and NC contacts are connected to the correct control functions.
- Restore control power in accordance with the equipment startup procedure.
- Verify relay pickup and dropout behavior against the approved protection settings.
- Confirm that downstream interlocks and alarms operate correctly.
Power-Off
- Notify the responsible operator before maintenance.
- Isolate the relevant control supply.
- Verify that the circuit is de-energized.
- Record terminal connections before disconnecting wiring.
- Remove the relay using the approved maintenance procedure.
- Protect the relay and disconnected conductors from mechanical damage and contamination.
Normal Operating Procedure
- Confirm that the relay is installed in the designated control panel or switchgear assembly.
- Check that the coil supply is within the specified operating range.
- Monitor the associated undervoltage protection and control-circuit status.
- Verify that the relay changes contact state as designed when the voltage falls below its operating threshold.
- Confirm that the connected alarm, interlock, or control device responds correctly.
- Investigate unexpected relay operation by checking the supply voltage, wiring, coil condition, and contact circuit.
- Record inspection results and any replacement or adjustment work.
Parameter Settings and Modification
The IC2820-C100M3 is a relay rather than a programmable digital protection device. Its operating behavior is determined by its coil characteristics, internal construction, and contact arrangement.
- Coil Voltage: 230 V AC; do not substitute a different coil rating without engineering approval.
- Contact Configuration: 1 NO / 1 NC; verify the actual terminal diagram.
- Undervoltage Threshold: Confirm from the applicable GE technical documentation; do not assume an adjustable setting.
- Diode Configuration: Maintain the specified internal diode arrangement.
- Contact Loading: Check the applicable AC and DC switching ratings before connecting the load.
- Circuit Coordination: Confirm that the relay’s operation is coordinated with upstream and downstream protection devices.
Do not modify the relay internally or change the protection circuit without an approved engineering procedure.
Maintenance and Troubleshooting
Routine Maintenance
- Inspect the relay housing for cracks, discoloration, or signs of overheating.
- Check terminals for corrosion, looseness, or damaged insulation.
- Verify the control supply voltage with an appropriately rated meter.
- Inspect the NO and NC contact circuits for abnormal resistance or intermittent operation.
- Check the relay’s pickup and dropout response during scheduled maintenance.
- Maintain records of relay identification, test results, and replacement history.
Common Troubleshooting
Problem: Relay does not operate
Check the 230 V AC coil supply, terminal wiring, internal coil condition, and control-circuit continuity.
Problem: Relay operates intermittently
Inspect for unstable supply voltage, loose terminals, damaged wiring, or a deteriorated coil.
Problem: Incorrect contact response
Verify the NO/NC terminal assignments and test contact continuity in both energized and de-energized states.
Problem: Relay overheats
Check the coil supply voltage, operating frequency, ambient temperature, and signs of internal damage.
Problem: Undervoltage protection does not respond correctly
Verify the relay model, coil supply, circuit wiring, and specified operating threshold. Check the complete protection logic before replacing the relay.
Safety Precautions
- Installation and maintenance must be performed by qualified electrical personnel.
- Isolate and verify the absence of hazardous voltage before handling the relay.
- Use appropriate PPE and follow the site’s lockout/tagout procedure.
- Never exceed the relay’s specified coil voltage or contact ratings.
- Observe the internal diode configuration and the manufacturer’s terminal diagram.
- Do not bypass undervoltage protection or safety interlocks to maintain equipment operation.
- Test the complete protection circuit before returning the equipment to service.
Recommended GE Models
The following GE models are related relay-family components or power-system protection products. They are not confirmed direct replacements for IC2820-C100M3. Verify coil voltage, contact arrangement, operating function, and mounting compatibility before substitution.
- IC2820-C100M2 – Undervoltage Relay with Diode, 115 V AC coil
- IC2820-C100N2 – Undervoltage Relay with Diode, 2 NO / 2 NC
- IC2820-C100N3 – Undervoltage Relay with Diode, 2 NO / 2 NC
- IC2820-C100C3 – Undervoltage Relay, 1 NO / 1 NC
- IC2820-C100C7 – Undervoltage Relay, 110 V AC
- IC2820-C100C21 – Undervoltage Relay, 220 V AC
- IC2820-C100L2 – Field-Reset Relay, 125 V DC
- IC2820-C100L3 – Field-Reset Relay, 250 V DC
- IC2820-C100B10 – Field-Apply Auxiliary Relay
- IC2820-C100B11 – Field-Apply Relay, 250 V DC
- IC2820-A102AK – Ground-Fault Differential Relay
- IC2820-A102AM – Ground-Fault Differential Relay
- IC2820-A103E – Ground-Fault Relay
- IC2820-D300A12 – Field-Loss Relay
- IC2820-D300A17 – Field-Loss Relay