Product Description
The GENERAL ELECTRIC IS200TVIBH2BCC is a Vibration Input Terminal Board designed for GE Mark VI Speedtronic turbine control systems. It provides the field interface for vibration monitoring probes, routing sensor signals to the associated VVIB vibration processor for monitoring and protection functions. The board supports proximity, velocity, acceleration, seismic, and phase-related measurements, and provides probe excitation power for compatible sensors. Its H2 version includes BNC connectors for portable vibration data collection equipment, alongside the permanent field connections. It can be used in approved Simplex and Triple Modular Redundant (TMR) configurations. Before installation or replacement, verify the complete part number, board revision, VVIB compatibility, probe wiring, and system configuration.

Product Datasheet
- Brand: General Electric (GE)
- Model: IS200TVIBH2BCC
- Series: Mark VI Speedtronic
- Product Name: Vibration Input Terminal Board
- Product Family: TVIB
- Main Function: Vibration probe signal termination and routing
- Probe Channels: 13 probe inputs, as listed in product references; verify the installed channel configuration
- Probe Power: -24 V DC
- Input Signal Span: -8 mV to +45 mV (published reference specification; confirm against the applicable probe and system documentation)
- Connectors: Field terminal blocks, processor-interface connectors, and BNC monitoring connectors
- Compatible Processor: GE VVIB vibration processor
- Redundancy: Simplex and TMR, subject to the installed system design
- Operating Temperature: 0 to +45 °C (published reference)
- Dimensions: Approximately 330 × 178 mm
- Weight: Approximately 0.58 kg
- Place of Manufacture: Not independently verified
- Country of Origin: Reported as USA; confirm from the product nameplate or origin documentation
- Product Status: Legacy Mark VI component; current OEM lifecycle status not confirmed
- Power Requirements: Probe excitation is supplied through the associated vibration-monitoring architecture; verify the exact supply and loading requirements in the GE manual
- Discontinued: Not confirmed
- Condition: Subject to seller confirmation
Operating Guidelines and Usage
1. System Compatibility
- Confirm that the receiving system is a GE Mark VI installation designed for the TVIB board.
- Verify the associated VVIB processor and the required Simplex or TMR arrangement.
- Check the complete board label, revision suffix, mounting position, and cable assembly before ordering or installation.
- Do not assume compatibility with Mark VIe I/O packs or other GE terminal-board families.
2. Probe and Signal Connections
- Identify each field probe by channel number and measurement function.
- Match proximity, velocity, acceleration, seismic, and phase probe types to the approved channel configuration.
- Check signal polarity, cable shielding, grounding, and terminal assignments against the wiring drawings.
- Use the BNC connections for approved portable vibration data-gathering equipment.
- Confirm that the connected probe is compatible with the board’s excitation and input characteristics.
3. Configuration
- Check the JP1–JP8 jumper settings where applicable to the first eight probe channels.
- Confirm probe type and channel assignment before applying power.
- Record existing jumper positions and wiring before replacing the board.
- Verify the VVIB processor configuration and alarm or trip limits after installation.
Power-On and Power-Off Sequence
Power-On
- Confirm that the equipment is isolated from hazardous energy before completing installation work.
- Inspect the board, connectors, terminal blocks, and cables for physical damage.
- Verify the board identity, mounting position, and jumper configuration.
- Confirm that all probe connections match the approved wiring drawings.
- Restore control-system power using the site’s approved startup procedure.
- Check the associated VVIB processor and Mark VI diagnostics.
- Confirm that probe readings, channel status, and alarm indications are consistent with the commissioning records.
Power-Off
- Notify the control-room operator and follow the approved turbine shutdown or maintenance procedure.
- Place the affected monitoring or protection function in the approved maintenance state, if required by the site procedure.
- Isolate the relevant power sources and verify the absence of hazardous voltage.
- Disconnect cables only after recording their channel assignments and routing.
- Remove the board using the approved handling procedure.
- Protect the removed board from electrostatic discharge and physical damage.
Normal Operating Procedure
- Check the Mark VI system status and associated VVIB processor diagnostics.
- Review vibration, shaft position, and Keyphasor-related measurements where configured.
- Compare readings with established operating baselines and approved alarm limits.
- Investigate abnormal readings by checking the probe, extension cable, connections, and channel configuration.
- Use the BNC monitoring outputs with approved portable diagnostic equipment when additional signal analysis is required.
- Record channel faults, maintenance actions, and any configuration changes.
- Confirm that all affected monitoring and protection functions are available before returning the equipment to normal service.
Parameter Settings and Modification
The IS200TVIBH2BCC is primarily a field termination and signal-interface board. Its configuration must be coordinated with the associated VVIB processor and the Mark VI application.
- Probe Type: Confirm the installed sensor type and its approved channel assignment.
- Jumper Configuration: Verify JP1–JP8 settings against the applicable GE documentation.
- Channel Mapping: Maintain the correct relationship between field terminals, processor inputs, and turbine monitoring tags.
- Alarm Limits: Check vibration and position alarm thresholds in the approved control-system configuration.
- Probe Power: Confirm that the connected sensors are suitable for the specified excitation supply.
- Redundancy: Verify the correct processor connections for the installed Simplex or TMR architecture.
Do not change jumper positions, alarm limits, or channel assignments while the turbine is operating unless the approved site procedure explicitly permits the work.
Maintenance and Troubleshooting
Routine Maintenance
- Inspect terminal blocks and connectors for looseness, corrosion, or contamination.
- Check field cables for damaged insulation, poor shielding, or incorrect routing.
- Review VVIB diagnostics and compare probe readings with historical operating data.
- Inspect BNC connectors for damage and confirm that unused connections are properly protected.
- Keep the board clean and dry, and follow appropriate ESD precautions during handling.
- Maintain records of board revisions, wiring changes, probe replacements, and test results.
Common Troubleshooting
Problem: No vibration signal
Check probe power, field wiring, terminal connections, probe condition, and the associated VVIB processor.
Problem: Unstable or fluctuating readings
Inspect cable shielding, grounding, connector condition, electromagnetic interference, and probe mounting.
Problem: Incorrect measurement scaling
Verify the probe type, channel assignment, jumper configuration, and VVIB software settings.
Problem: Probe fault or channel alarm
Check for an open circuit, short circuit, damaged cable, failed probe, or incorrect excitation connection.
Problem: Portable analyzer receives no BNC signal
Inspect the BNC connector, test cable, measurement equipment, and the applicable buffered output.
Problem: TMR channel disagreement
Compare the corresponding R, S, and T channel connections and diagnostics. Check the probe signal path and processor configuration before identifying a board fault.
Safety Precautions
- Installation and maintenance must be performed by qualified industrial control-system personnel.
- Follow the turbine manufacturer’s isolation, lockout/tagout, and electrical safety procedures.
- Never disconnect vibration protection wiring or bypass alarm and trip functions without formal authorization.
- Confirm that replacement hardware matches the complete part number and approved system configuration.
- Use ESD protection when handling the printed circuit board.
- Do not apply external voltage to signal terminals unless explicitly permitted by the GE documentation.
- After replacement, verify the affected monitoring channels and protection functions before returning the turbine to service.
Recommended GE Models
The following GE models are related Mark VI control-system components or associated turbine-control hardware. They are not all direct replacements for the IS200TVIBH2BCC; confirm each model’s function and system compatibility before ordering.
- IS200VVIBH1C – Vibration Processor Board
- IS200TBTCH1C – Thermocouple Input Terminal Board
- IS200VTCCH1C – Thermocouple Input Board
- IS200TBAIH1C – Analog Input Terminal Board
- IS200TBCIH1C – Contact Input Terminal Board
- IS200TBACIH1B – Analog/Contact Input Terminal Board
- IS200VRTDH1D – Resistance Temperature Detector Input Board
- IS200VGENH1B – Generator Control Board
- IS200VPROH1B – Protection Processor Board
- IS200VCMIH2B – VME Controller Interface Board
- IS200VCRCH1B – VME Control Rack Interface Board
- IS200TREGH1B – Regulator Interface Board
- IS200TDBTH2A – Discrete Terminal Board
- IS200TBCIH1A – Contact Input Terminal Board
- IS200TVIBH2B – TVIB Vibration Input Terminal Board, related hardware family; verify the complete revision and connector configuration before considering substitution.