Product Introduction
The GENERAL ELECTRIC SKHA36AT0800 is a three-pole, 800 A molded case circuit breaker from the GE Spectra RMS series, designed for industrial power distribution and electrical protection applications. Built on the SK1200 frame platform, this 600 VAC circuit breaker features a solid-state RMS-sensing electronic trip system that accurately monitors sinusoidal and non-sinusoidal current conditions. Its LSI protection functions include long-time, short-time, and instantaneous overcurrent protection, with adjustable short-time and instantaneous settings. The breaker supports interchangeable front-mounted rating plugs, allowing the current rating to be selected according to the application requirements. With a 50 kA interrupting rating at 480 VAC, reverse-feed capability, and three-phase circuit protection, the SKHA36AT0800 is suitable for industrial switchgear, motor distribution systems, generator auxiliary circuits, and large electrical distribution panels. It uses a bolt-on mounting configuration and requires compatible terminal lugs for installation.

Technical Datasheet
| Parameter | Specification |
|---|---|
| Brand | General Electric (GE) |
| Model | SKHA36AT0800 |
| Series | Spectra RMS |
| Product Name | Molded Case Circuit Breaker |
| Place of Manufacture | GE Industrial Solutions |
| Product Status | Legacy / Discontinued Product |
| Dimensions | 15.5 × 8.3 × 5.5 in (H × W × D) |
| Weight | Approx. 35–57 lb, depending on supplier reference |
| Country of Origin | United States (verify nameplate) |
| Power Requirements | Passive electromechanical protection device; no separate control power specified |
| Rated Current | 800 A |
| Rated Voltage | 600 VAC |
| Number of Poles | 3 |
| Interrupting Capacity | 50 kA at 480 VAC |
| Trip Function | LSI – Long-Time, Short-Time, Instantaneous |
| Frame Type | SK1200 |
| Frequency | 50/60 Hz |
| Mounting | Bolt-On |
| Terminal Lugs | TCAL81 compatible; verify inclusion separately |
Main Technical Features
- Three-pole molded case circuit breaker.
- 800 A current rating.
- 600 VAC maximum system voltage.
- Spectra RMS electronic trip technology.
- Solid-state RMS current sensing.
- LSI overcurrent protection.
- Interchangeable front-mounted rating plug.
- Adjustable short-time and instantaneous trip functions.
- Fixed long-time protection characteristic.
- 50 kA interrupting capacity at 480 VAC.
- Suitable for reverse-feed applications.
- Designed for industrial switchgear and power distribution.
Operating Procedures and Usage Instructions
1. Installation Preparation
- Confirm the complete model number and nameplate ratings.
- Verify that the system voltage does not exceed the breaker rating.
- Check the available short-circuit current against the interrupting capacity.
- Confirm the three-phase connection arrangement.
- Verify compatible terminal lugs and conductor sizes.
- Inspect the breaker housing, terminals, and operating mechanism.
- Check mounting dimensions and panel compatibility.
- Confirm that the selected rating plug matches the required protection settings.
⚠️ Installation must be performed by qualified electrical personnel with the circuit isolated.
2. Power-On Sequence
- Confirm that the breaker is in the OFF position.
- Inspect all incoming and outgoing electrical connections.
- Verify terminal torque according to the manufacturer’s instructions.
- Check phase identification and conductor insulation.
- Verify the protection settings and rating plug.
- Complete the required insulation and continuity tests.
- Confirm that downstream equipment is ready for energization.
- Close the breaker according to the approved electrical commissioning procedure.
- Monitor load current and check for abnormal heating or tripping.
3. Normal Operating Procedure
- Check the breaker position indicator.
- Confirm that the connected electrical load is within the rated operating conditions.
- Monitor phase currents using external metering equipment.
- Check for abnormal noise, vibration, or overheating.
- Observe the breaker for unexpected trips.
- Review protection coordination with upstream and downstream devices.
- Record trip events and investigate abnormal operating conditions.
- Perform periodic mechanical and electrical inspections.
4. Parameter Settings and Modification
The SKHA36AT0800 uses a solid-state RMS electronic trip system rather than a PLC-style programming interface.
- Identify the installed rating plug.
- Verify the selected ampere rating against the system design.
- Review the long-time protection characteristics.
- Adjust short-time protection according to the approved coordination study.
- Configure instantaneous protection within the permitted trip-unit range.
- Verify the trip settings against cable, busbar, and equipment ratings.
- Perform the required trip testing after adjustment.
- Record the final protection settings.
Important: The long-time characteristic is established through the interchangeable rating plug. Do not assume that all protection settings are independently adjustable.
5. Shutdown Procedure
- Notify the electrical operations team.
- Transfer the connected load if required.
- Open the breaker using its approved operating mechanism.
- Verify the OFF position.
- Isolate upstream power where maintenance is required.
- Apply lockout/tagout procedures.
- Verify absence of voltage using an appropriately rated tester.
- Perform maintenance only after electrical isolation is confirmed.
Daily Maintenance and Troubleshooting
Routine Maintenance
- Inspect the breaker housing for cracks or damage.
- Check terminal connections for overheating.
- Inspect the operating handle and mechanical mechanism.
- Verify the breaker mounting and fastening hardware.
- Check for corrosion or contamination.
- Review historical trip events.
- Verify protection coordination periodically.
- Perform electrical testing according to the maintenance schedule.
Common Troubleshooting
Problem: Breaker trips unexpectedly
- Check for overload conditions.
- Inspect downstream circuits for short circuits.
- Review LSI trip settings.
- Verify the rating plug selection.
Problem: Breaker fails to close
- Check the mechanical operating mechanism.
- Verify that the breaker is fully reset.
- Inspect for mechanical interlock conditions.
- Check for internal damage.
Problem: Excessive terminal heating
- Inspect conductor connections.
- Verify terminal torque.
- Check conductor sizing.
- Inspect contact surfaces for deterioration.
Problem: Breaker trips during motor startup
- Review motor starting current.
- Check short-time and instantaneous settings.
- Verify coordination with downstream motor protection.
- Confirm that the breaker is correctly selected for the application.
Problem: Incorrect protection operation
- Verify the rating plug.
- Inspect the electronic trip unit.
- Perform approved trip-unit testing.
- Replace defective components with manufacturer-approved parts.
Frequently Asked Questions
Q1: What is the GE SKHA36AT0800?
It is an 800 A, three-pole molded case circuit breaker from the GE Spectra RMS series.
Q2: What is its maximum rated voltage?
The breaker is rated for systems up to 600 VAC.
Q3: What protection functions does it provide?
It provides LSI protection: long-time, short-time, and instantaneous overcurrent protection.
Q4: What is the interrupting capacity?
Its interrupting rating is 50 kA at 480 VAC.
Q5: Can it be used for reverse-feed applications?
Yes. The manufacturer’s product specifications identify it as suitable for reverse-feed applications.
Q6: Does it include terminal lugs?
The standard product specification identifies TCAL81 lugs, but some supplier listings indicate that lugs are not included. Confirm the supplied accessories before ordering.
Q7: Is the breaker suitable for generator distribution panels?
It can be used in appropriately engineered generator distribution systems, provided voltage, fault current, protection coordination, and installation requirements are satisfied.
Safety Precautions
⚠️ Never install or service the breaker while energized.
⚠️ Verify short-circuit interrupting capacity before installation.
⚠️ Use correctly rated conductors and compatible terminal lugs.
⚠️ Never exceed the manufacturer’s current and voltage ratings.
⚠️ Protection settings must follow an approved coordination study.
⚠️ Perform insulation and trip testing using appropriate procedures.
⚠️ Only qualified electrical technicians should perform commissioning and maintenance.
Recommended GE Models
- SKHA36AT1200 – 1200 A Spectra RMS Circuit Breaker
- SKLA36AT0800 – Spectra RMS Circuit Breaker
- SKPA36AT0800 – Spectra RMS Circuit Breaker
- SKHA36AT0600 – 600 A Circuit Breaker
- SKHA36AT0700 – 700 A Circuit Breaker
- SKHA26AT0800 – Two-Pole Circuit Breaker
- SKHA26AT1200 – Two-Pole Circuit Breaker
- SGHA36AT0600 – Spectra RMS Circuit Breaker
- SFHA36AT0250 – Spectra RMS Circuit Breaker
- SEHA36AT0150 – Spectra RMS Circuit Breaker
- SKLA36AT1200 – 1200 A Circuit Breaker
- SKPA36AT1200 – High-Interrupting-Capacity Circuit Breaker
- SGHA36AT0400 – 400 A Circuit Breaker
- SFHA36AT0200 – 200 A Circuit Breaker
- SEHA36AT0100 – 100 A Circuit Breaker
Note: These are related GE Spectra RMS product models and frame variants, not guaranteed direct replacements. Verify voltage, poles, frame, interrupting capacity, trip characteristics, and mounting compatibility before substitution.