1. Product Description
The HIMA F3328A is a safety-related switching amplifier module designed for HIMA Planar F safety systems. Identified by part number 984332860 (98 4332860), this module provides an intrinsically safe (Ex i) output for applications requiring controlled switching between safety-system logic and field devices. The F3328A is listed with ATEX approval and SIL 3 / Category 4 safety classification in HIMA’s discontinued-products documentation. It is intended for use in established industrial safety installations, including applications involving field devices in potentially explosive atmospheres. The F3328A is a specialized safety switching component, not a general-purpose PLC input or output card. Before replacement or installation, verify the exact module version, system configuration, field-device requirements, and applicable hazardous-area certification.

2. Key Technical Specifications
- Brand: HIMA
- Model: F3328A
- Part Number: 984332860 / 98 4332860
- Product Series: Planar F
- Product Type: Safety-Related Switching Amplifier
- Main Function: Safety-related switching and signal amplification
- Output Type: Intrinsically safe (Ex i) output
- Output Voltage: 24 VDC (as identified in the discontinued-products documentation)
- Safety Classification: SIL 3 / Category 4 (listed product classification; verify application-specific certification)
- Hazardous-Area Approval: ATEX (listed for this model)
- System Compatibility: HIMA Planar F
- Country of Origin: Germany (manufacturer location; verify the individual unit’s label)
- Product Status: Discontinued; listed end of life March 31, 2022
- Dimensions: Not officially confirmed
- Weight: Not officially confirmed
- Power Consumption: Not independently verified; refer to the original technical documentation
3. Application Scenarios
- Oil and gas facilities: Safety-related switching between control-system logic and field equipment.
- Chemical processing: Signal switching in safety circuits serving process equipment.
- Hazardous-area installations: Applications requiring an intrinsically safe output interface.
- Emergency shutdown systems: Use within an engineered safety-related switching arrangement.
- Industrial process plants: Maintenance of existing HIMA Planar F safety cabinets.
- Power generation: Spare-part support for legacy safety-related control installations.
- Plant maintenance: Replacement planning for installed F3328A modules where the original configuration must be preserved.
4. Installation and Operating Procedure
- Verify the module identification, including F3328A and part number 984332860.
- Confirm the required safety function and field-device interface against the approved circuit drawings.
- Check the hazardous-area classification and confirm that the complete installation meets the applicable intrinsic-safety requirements.
- Place the affected process and safety function into its approved maintenance state.
- Isolate the relevant power sources and apply lockout/tagout procedures.
- Record the original module position, wiring, terminals, and field-device connections.
- Inspect the replacement module for damage, corrosion, contamination, and connector deterioration.
- Install the module in the designated HIMA Planar F position according to the applicable installation documentation.
- Verify all field wiring, grounding, shielding, and intrinsic-safety circuit requirements.
- Perform the approved switching, signal, and safety-function tests.
- Document test results and obtain the required engineering approval before returning the system to service.
5. Configuration and System Integration
The F3328A is a hardware switching amplifier for the HIMA Planar F system. Its use depends on the original safety circuit, connected field equipment, and hazardous-area installation design.
Important integration checks include:
- Confirm the exact F3328A part number and hardware identification.
- Verify the module’s designated Planar F mounting position.
- Check the input and output wiring against the approved circuit diagrams.
- Confirm the field-device electrical characteristics and switching requirements.
- Verify the intrinsic-safety interface and applicable ATEX documentation.
- Review the safety-system design and required SIL / Category 4 validation.
- Confirm whether the installed system requires additional interface or terminal components.
Do not assume that the older F3328 or another HIMA switching amplifier has identical hazardous-area approval or electrical characteristics. The F3328 predecessor is identified separately in HIMA’s product lifecycle documentation.
6. Daily Maintenance and Inspection
- Inspect the module and connectors for visible damage, corrosion, or contamination.
- Check the control cabinet environment and maintain the specified temperature and ventilation conditions.
- Inspect field wiring and terminals for loose connections or insulation damage.
- Review available system diagnostics and maintenance records.
- Check associated field devices for abnormal switching behavior.
- Verify that hazardous-area wiring and segregation requirements remain intact.
- Maintain records of module identification, replacement history, and functional test results.
- Perform periodic safety-function testing according to the plant’s approved maintenance schedule.
7. Troubleshooting Guide
Problem: Field device does not switch.
- Verify the module’s correct installation and identification.
- Check the field-device wiring and supply conditions.
- Inspect the associated safety-system input and output signals.
- Review the approved circuit diagram and switching sequence.
Problem: Unexpected switching behavior.
- Check the control signal and associated logic conditions.
- Inspect the wiring for short circuits, loose terminals, or incorrect connections.
- Verify that the connected field device matches the approved design.
- Arrange qualified technical investigation before returning the circuit to operation.
Problem: Intrinsic-safety circuit cannot be accepted.
- Verify the field-device and interface documentation.
- Review hazardous-area wiring, cable parameters, and installation segregation.
- Confirm the applicable ATEX documentation and system design.
- Do not energize the affected circuit until the safety requirements have been verified.
Problem: Module replacement causes a system fault.
- Confirm the replacement is the correct F3328A version.
- Check the mounting position and connection arrangement.
- Verify the wiring and associated field-device configuration.
- Complete the approved functional and safety validation procedure.
8. Safety Precautions
- Installation and maintenance must be performed by qualified personnel familiar with HIMA safety systems.
- Follow electrical isolation and lockout/tagout procedures.
- Observe all applicable hazardous-area and intrinsic-safety installation requirements.
- Do not modify or bypass safety-related circuits to overcome a fault.
- Do not substitute the older F3328 or another switching amplifier without engineering approval.
- Verify the complete field circuit, not just the individual module certification.
- Do not assume that an individual module’s SIL classification automatically establishes the SIL capability of the complete safety function.
- Complete the required safety validation and commissioning tests before returning the system to service.
9. Related HIMA Models
The following HIMA models are related to Planar F switching, safety logic, and I/O functions. They are useful for spare-part identification and system maintenance, but they are not automatically interchangeable with F3328A.
- F3328 – Earlier Planar F switching amplifier model.
- F3318A – Safety-related switching amplifier with intrinsically safe output.
- F3319A – Safety-related switching amplifier with AND/OR pre-logic.
- F3316A – Safety-related switching amplifier.
- F3315 – Four-channel safety-related switching amplifier.
- F3324 – Two-channel safety-related switching amplifier.
- F3326A – Safety-related switching amplifier for 60 VDC applications.
- F3329A – Safety-related switching amplifier with AND/OR pre-logic.
- F3330 – HIMA digital output module.
- F3331 – HIMA safety-related digital output module.
- F3333 – Four-channel safety-related digital output module.
- F3334 – Four-channel safety-related digital output module.
- F3430 – Safety-related relay output module.
- F4110A – Safety-related logic function module.
- F4204 – Planar F safety-related logic function module.
10. Product Verification and Purchasing Notes
Before purchasing, request clear photographs of the actual module showing the front label, full part number, connectors, and revision markings. Confirm whether the unit is new surplus, unused, refurbished, or previously installed. Ask the supplier whether functional testing has been completed and whether a test report is available.
The HIMA discontinued-products list records the F3328A as discontinued from April 1, 2012, with an end-of-life date of March 31, 2022. It identifies H4007 as a function-compatible alternative, but not a pin-compatible replacement. Therefore, H4007 must not be treated as a direct plug-in substitute. Any replacement or migration requires engineering verification of wiring, electrical characteristics, hazardous-area requirements, and the complete safety function.
For legacy HIMA Planar F installations, verify the original system documentation and the exact field-device interface before ordering or commissioning a replacement.