Product Introduction
The Phoenix Contact AXL F PSDOR4/2 1F (Order Number: 2702858) is a functional safety relay output module in the Axioline F remote I/O system. Designed for PROFIsafe communication, it provides four floating, normally open safety relay outputs, two signal inputs, and two additional 24 V DC outputs. The module is intended for integration with compatible Phoenix Contact or Siemens controllers and allows safety-related control signals to switch external loads through electrically isolated relay contacts. Typical applications include machine safety circuits, contactor control, industrial equipment shutdown, and automated production systems. With configurable PROFIsafe operation, DIN-rail mounting, and a compact yellow housing, the module is suitable for distributed safety I/O installations. Correct operation depends on the compatible bus base, controller configuration, safety parameters, and external supply wiring.

Technical Specifications
- Brand: Phoenix Contact
- Model: AXL F PSDOR4/2 1F
- Order Number: 2702858
- GTIN: 4055626363271
- Product Name: Functional Safety Relay Output Module
- Product Type: Safety-Related Digital I/O / Relay Module
- Product Series: Axioline F
- Communication Protocol: PROFIsafe 2.4 / PROFIsafe 2.6.1
- Controller Compatibility: Phoenix Contact or Siemens controllers
- Signal Inputs: 2
- Additional Digital Outputs: 2 (OUT24V_0 and OUT24V_1)
- Safety Relay Outputs: 4 floating outputs
- Relay Contact Type: Normally Open (NO)
- Relay Contact Material: AgSnO₂
- Relay Switching Voltage: 12–30 V AC/DC
- Maximum Relay Switching Current: 6 A at 30 V DC
- Limiting Continuous Current: 6 A
- Mechanical Service Life: 10 million switching cycles
- Input Supply: 24 V DC for EDM-related supply
- Safe I/O Supply: 24 V DC through U0 and U1
- Supply Voltage Range: 19.2–30 V DC
- Local Bus Supply: 5 V DC through the bus base module
- Protection Rating: IP20
- Mounting Type: DIN rail
- Housing Color: Yellow (RAL 1018)
- Dimensions: 53.6 × 126.1 × 54 mm
- Weight: 218 g (unpacked); 270 g (including packaging)
- Operating Temperature: -35 °C to +60 °C
- Place of Manufacture: Germany
- Country of Origin: Germany
- Product Status: Industrial safety I/O component; verify current lifecycle status
- Discontinued: Not confirmed as discontinued
- Connection Method: Push-in connection and Axioline F bus base module
- Maximum Power Dissipation: 6.255 W under nominal conditions
- Output Fuse Requirement: 6 A gL/gG, according to the applicable application circuit
Key Technical Features
- PROFIsafe Communication: Supports PROFIsafe 2.4 and 2.6.1 for safety-related communication with compatible controllers.
- Four Safety Relay Outputs: Provides four floating normally open relay contacts for switching external safety-related circuits.
- Two Signal Inputs: Supports two signal inputs for the configured safety application.
- Two Additional 24 V Outputs: Provides OUT24V_0 and OUT24V_1 outputs supplied from the corresponding safe I/O power feeds.
- Electrical Isolation: Floating relay contacts provide electrical separation between the relay contact circuits and internal electronics.
- High Switching Capacity: Each relay output supports switching currents up to 6 A under the specified voltage and load conditions.
- Axioline F Integration: Connects to the local bus through the appropriate bus base module.
- Flexible Installation: Supports DIN-rail mounting in compatible Axioline F remote I/O stations.
- Diagnostic and Monitoring Functions: Supports safety-related status monitoring through the configured controller and PROFIsafe communication.
- Industrial Environmental Range: Designed for operation from -35 °C to +60 °C under specified installation conditions.
Operating Procedures
1. Pre-Installation Inspection
- Verify the complete model designation AXL F PSDOR4/2 1F.
- Confirm order number 2702858.
- Inspect the housing, terminals, and connection contacts for damage.
- Check the module revision and product label.
- Confirm that the controller supports the required PROFIsafe operating mode.
- Verify the Axioline F bus base and local bus configuration.
- Review the safety application, I/O mapping, and F-parameter configuration.
- Confirm that the external relay loads meet the specified voltage and current limits.
2. Installation
- ⚠️ Place the machine or affected safety circuit in its approved maintenance state.
- Isolate electrical power before installing or removing the module.
- Install the appropriate Axioline F bus base module on the DIN rail.
- Mount the AXL F PSDOR4/2 1F in the designated station position.
- Connect the local bus through the bus base module.
- Wire the two signal inputs and two 24 V outputs according to the electrical drawings.
- Connect the four floating relay outputs to the intended external circuits.
- Provide the required 24 V DC supply feeds for U0, U1, and UI.
- Install the specified external protective devices.
- Verify terminal assignments, polarity, conductor cross-sections, and grounding before energizing.
3. Startup and Power-On
- Inspect the module installation and terminal connections.
- Verify the 24 V DC supply voltage is within the specified 19.2–30 V DC range.
- Confirm the 5 V local bus supply is available through the bus base module.
- Restore power according to the controller manufacturer’s startup procedure.
- Check that the controller recognizes the module.
- Verify the configured PROFIsafe communication and parameter data.
- Confirm that all safety-related inputs and output channels report the expected status.
- Test each relay output using an approved commissioning procedure.
- Verify the external contactors or loads respond correctly.
- Complete the required safety validation before returning the machine to normal operation.
4. Normal Operation
During normal operation, the module exchanges safety-related data with its compatible controller over PROFIsafe. The controller manages the safety logic and commands the module’s relay outputs according to the configured application. The four floating relay contacts switch the connected external circuits, while the two additional 24 V outputs provide their designated functions. Maintenance personnel should monitor communication status, supply conditions, relay switching behavior, and safety-system diagnostics.
5. Parameter Configuration and Modification
The AXL F PSDOR4/2 1F is configured through the compatible controller engineering environment. Relevant configuration items include:
- PROFIsafe address and F-parameter settings.
- Module identification and I/O assignment.
- Safety input configuration.
- Relay output channel assignment.
- Safe supply configuration for U0 and U1.
- EDM-related signal configuration.
- Controller-side safety logic and diagnostic monitoring.
The module requires 20 bytes of parameter data and 10 bytes of configuration data according to the published system specifications. Back up the controller project before making changes. Any modification to safety parameters or logic must be reviewed, validated, and authorized under the site’s functional safety procedures.
6. Shutdown Procedure
- Place the controlled machine in its approved safe state.
- Stop the affected process using the authorized shutdown sequence.
- Confirm that external contactors and connected loads have reached the required condition.
- Isolate the module’s power supplies.
- Verify that no hazardous voltage remains on external relay circuits.
- Disconnect wiring only after confirming electrical isolation.
- Record the module configuration and diagnostic information before removal.
Daily Maintenance
- Inspect the module housing for damage and contamination.
- Check that the module remains securely mounted on the DIN rail.
- Inspect push-in terminals for loose or damaged conductors.
- Monitor the 24 V DC supply and local bus status.
- Review PROFIsafe communication diagnostics.
- Check for recurring safety-channel faults.
- Inspect external relay loads and contactors for abnormal operation.
- Confirm that external protective devices match the approved electrical design.
- Review the switching history of critical relay circuits.
- Maintain current controller project backups and safety documentation.
- Perform periodic proof testing according to the machine safety lifecycle requirements.
Troubleshooting
Problem 1: Module is not recognized by the controller
Possible causes: Incorrect bus base installation, local bus connection failure, incompatible controller configuration, or incorrect module identification.
Recommended action: Check the bus base, local bus connection, controller hardware configuration, and module order number. Review the controller diagnostic messages.
Problem 2: PROFIsafe communication fault
Possible causes: Incorrect F-address, mismatched safety parameters, controller configuration errors, or communication interruptions.
Recommended action: Verify the PROFIsafe address and F-parameter settings. Compare the module configuration with the approved engineering project.
Problem 3: Safety relay output does not switch
Possible causes: Missing U0 or U1 supply, incorrect safety logic state, output-channel fault, or external wiring problems.
Recommended action: Verify the relevant supply feed, controller output command, relay contact wiring, and external protective devices.
Problem 4: Relay output switches intermittently
Possible causes: Unstable supply voltage, excessive load current, loose wiring, or unsuitable load characteristics.
Recommended action: Measure the supply voltage, inspect the terminal connections, and confirm that the connected load is within the relay’s switching limits.
Problem 5: Safety input signal is not detected
Possible causes: Incorrect signal wiring, missing clock supply from UT1 or UT2, damaged field wiring, or incorrect controller configuration.
Recommended action: Check the input wiring and associated clock supply. Verify the input assignment and diagnostic status in the controller.
Problem 6: Module reports an internal or channel fault
Possible causes: Hardware failure, abnormal supply conditions, or an internal diagnostic error.
Recommended action: Record the diagnostic code, check the supply and wiring, and follow the manufacturer’s troubleshooting procedure. Replace the module only after confirming the fault and compatibility of the replacement.
Frequently Asked Questions
Q1: What is the Phoenix Contact AXL F PSDOR4/2 1F?
It is a functional safety relay output module in the Axioline F remote I/O family, designed for PROFIsafe applications.
Q2: What is the order number?
The official Phoenix Contact order number is 2702858.
Q3: How many relay outputs does this module provide?
It provides four floating normally open safety relay outputs.
Q4: What is the maximum relay switching current?
The specified maximum is 6 A at 30 V DC, subject to the applicable load and protective-device requirements.
Q5: Which controllers can be used with this module?
Phoenix Contact and Siemens controllers with compatible PROFIsafe support. Confirm the specific controller model and firmware before integration.
Q6: Does the module provide digital inputs?
Yes. It has two signal inputs and two additional 24 V outputs.
Q7: Can it be used as a standard relay output module?
It is designed as a functional safety module for PROFIsafe applications. It should not be treated as a generic non-safety relay module.
Q8: Is the AXL F PSDOR4/2 1F compatible with AXL F SSDOR4/2 1F?
They are related Axioline F safety relay modules, but their safety functions and configuration differ. Confirm the required safety architecture and manufacturer documentation before substitution.
Safety Precautions
- ⚠️ Installation and commissioning must be performed by qualified industrial safety personnel.
- ⚠️ Isolate all relevant power sources before wiring or replacing the module.
- ⚠️ Do not exceed the specified relay voltage and current ratings.
- ⚠️ Use the prescribed external fuses and protective devices.
- ⚠️ Never bypass PROFIsafe communication faults or safety interlocks.
- ⚠️ Verify F-addresses and safety parameters before commissioning.
- ⚠️ Perform documented functional testing after any wiring or configuration change.
- ⚠️ The IP20 module must be installed in an enclosure providing the required protection for the installation location.
- ⚠️ Follow Phoenix Contact documentation and applicable machine safety standards.
Related Phoenix Contact Models
The following products belong to related Axioline F safety I/O and relay module families. They are useful for system expansion and spare-parts identification, but are not all direct replacements.
- AXL F SSDOR4/2 1F – Safety relay output module, 2702859
- AXL F SSDO8/3 1F 24 V DC – Safety digital output module, 2702264
- AXL F PSDI8/4 1F 24 V DC – Safety digital input module, 2701559
- AXL F PSDO8/3 1F 24 V DC – Safety digital output module, 2701560
- AXL F LPSDO8/3 IF 24 V DC – SafetyBridge logic output module, 2702171
- AXL F PSAI8/2 1F – Safety analog input module, 1061424
- AXL F DI8/1 DO8/1 1H – Axioline F digital I/O module
- AXL F DI16/1 1H – Axioline F digital input module
- AXL F DO16/1 1H – Axioline F digital output module
- AXL F AI4 I – Axioline F analog input module
- AXL F AO4 I – Axioline F analog output module
- AXL F BK PN – Axioline F PROFINET bus coupler
- AXL F BK ETH – Axioline F Ethernet bus coupler
- AXL F BP SE4 – Axioline F module carrier
- AXL F US 8 – Axioline F supply module
Compatibility Notice: Related Axioline F modules have different safety functions, channel counts, communication requirements, and electrical characteristics. Confirm the exact order number, controller compatibility, bus base, PROFIsafe configuration, and safety application before selecting an alternative.