Product Description
The YASKAWA ELECTRIC JZNC-YSU01-1E is a Machine Safety Unit designed for the Yaskawa Motoman DX100 robot controller. It contains dual processing circuits for safety signals and manages the servo power contactor according to the status of external safety circuits. Its functions include robot-specific dual-channel safety I/O, Servo-ON Enable inputs, overrun and external overrun inputs, programming pendant emergency-stop signals, contactor control outputs, and emergency-stop signal processing. The unit connects to the controller’s safety-related circuits through dedicated connectors and works with the DX100 power supply contactor assembly. It is an important component in the robot controller’s safety architecture and should be installed only in a verified compatible DX100 configuration. The Yaskawa Motoman parts catalog identifies this unit as part number 155628-1.

Product Datasheet
- Brand: YASKAWA ELECTRIC
- Model: JZNC-YSU01-1E
- OEM Part Number: 155628-1
- Product Name: DX100 Machine Safety Unit
- Product Type: Safety Control Board Assembly
- Product Series: Motoman DX100
- Main Function: Dual-channel safety signal processing
- Safety Circuits: Robot-specific safety I/O, Servo-ON Enable, overrun, emergency stop, and pendant safety signals
- Output Function: Dual-channel servo power contactor control
- Associated Contactor Unit: JZRCR-YPU
- Connectors: CN200–CN216, depending on circuit function and controller configuration
- Fuses: F1 and F2, 3.15 A / 250 V, as identified in the DX100 manual
- Controller Compatibility: Yaskawa Motoman DX100
- Power Requirements: Refer to the DX100 controller wiring and maintenance manuals; standalone input rating not verified
- Dimensions: Not independently verified
- Weight: Manufacturer portal lists packaged weight of approximately 5.77 lb (2.62 kg)
- Country of Origin: Not independently verified
- Product Status: Current availability should be confirmed with Yaskawa or an authorized parts supplier
- Condition: Subject to seller confirmation
Operating Guidelines and Usage
- Confirm that the controller is a compatible DX100 system and that the installed unit matches JZNC-YSU01-1E.
- Verify the controller wiring diagram and connector assignments before reconnecting cables.
- Inspect safety input circuits, including emergency-stop, overrun, and Servo-ON Enable signals.
- Check the dual-channel signal paths for correct wiring and consistent switching behavior.
- Verify the contactor control connections to the JZRCR-YPU power supply contactor unit.
- Confirm that the controller reports normal safety status before attempting servo activation.
- Test emergency-stop and other safety functions using the approved commissioning procedure.
Power-On and Power-Off Sequence
Power-On
- Verify that all safety wiring and connector connections are secure.
- Confirm that emergency-stop devices are reset only after the work area is clear.
- Apply power to the DX100 controller according to the manufacturer’s procedure.
- Check the controller alarms and safety-unit status.
- Verify the dual-channel Servo-ON Enable and overrun circuits.
- Confirm correct contactor operation before enabling servo power.
- Perform controlled robot movement only after all safety checks pass.
Power-Off
- Stop robot motion and place the robot in a safe condition.
- Disable servo power using the approved controller procedure.
- Shut down and isolate the controller’s electrical supply.
- Verify that hazardous electrical energy has been removed before servicing.
- Disconnect the safety unit only after the system is fully isolated.
- Label all connectors and wiring before removal to prevent reconnection errors.
Normal Operating Procedure
- Monitor controller alarms related to emergency-stop, overrun, and Servo-ON Enable circuits.
- Verify that both channels of each applicable safety input operate consistently.
- Confirm that the servo power contactor responds correctly to safety-unit commands.
- Inspect connector retention and wiring condition during scheduled maintenance.
- Investigate unexpected servo-disable conditions before attempting a reset.
- Maintain records of safety-circuit tests, repairs, and controller configuration changes.
Parameter Settings and Modification
The JZNC-YSU01-1E is a dedicated safety hardware assembly rather than a general-purpose programmable I/O module. Its configuration depends on the DX100 controller design and the connected safety circuits.
- Do not alter safety wiring or jumper arrangements without the applicable Yaskawa documentation.
- Check Servo-ON Enable connections against the DX100 instructions manual.
- Verify external-axis overrun wiring where external axes are installed.
- Confirm emergency-stop and pendant safety circuits before returning the robot to service.
- Do not bypass dual-channel safety inputs or contactor feedback circuits.
- Record all approved wiring changes and complete the required safety validation.
Maintenance and Troubleshooting
Routine Maintenance
- Inspect the PCB and connectors for contamination, corrosion, overheating, or mechanical damage.
- Check the condition and seating of F1 and F2 fuses.
- Inspect safety wiring for loose terminals, damaged insulation, and incorrect connections.
- Verify the contactor wiring and mechanical condition of the associated contactor assembly.
- Check that the controller cabinet ventilation is operating correctly.
- Follow the Yaskawa maintenance schedule for the DX100 controller.
Common Troubleshooting Checks
- Safety alarm remains active: Check emergency-stop devices, dual-channel input wiring, and controller diagnostics.
- Servo power cannot be enabled: Verify Servo-ON Enable signals and the contactor control circuit.
- Overrun alarm: Inspect OT and EXOT input circuits, limit devices, and external-axis wiring where applicable.
- Contactor does not operate: Check the safety-unit output connections, contactor assembly, and associated power circuits.
- Intermittent safety fault: Inspect connector seating, wiring continuity, and possible damaged contacts.
- Fuse failure: Identify and correct the underlying electrical fault before replacing the fuse with the specified rating.
Safety Precautions
- Installation and servicing must be performed by qualified robot-control and electrical safety personnel.
- Isolate the DX100 controller and verify the absence of hazardous voltage before handling the unit.
- Never bypass, short, or defeat dual-channel safety circuits.
- Do not substitute fuses with different current or voltage ratings.
- Do not assume that a visually similar Yaskawa safety board is interchangeable.
- Validate emergency-stop, overrun, Servo-ON Enable, and contactor functions after replacement.
- Complete the required machine risk assessment and safety validation before returning the robot to production.
Recommended YASKAWA Related Models
The following components are associated with the Yaskawa Motoman DX100 controller system. They are related spare parts, not direct replacements for the JZNC-YSU01-1E.
- JZNC-YRK01-E – DX100 CPU Unit
- JANCD-YCP01-E – DX100 CPU Board
- JANCD-YIF01-1E – DX100 Robot Interface Board
- JZNC-YPS01-E – DX100 Control Power Supply Unit
- JZNC-YIU01-E – DX100 Robot I/O Unit
- JANCD-YBK01-1E – DX100 Brake Relay Board
- JZRCR-YPU01-1 – DX100 Power Supply Contactor Unit
- JZRCR-YPP01-1 – DX100 Programming Pendant
- JZNC-YSU01-1E – DX100 Machine Safety Unit
- JZRCR-YPU – Servo Power Supply Contactor Assembly
- JANCD-YCP01 – Yaskawa Controller CPU Board
- JZNC-YIU01 – Yaskawa Robot I/O Unit
- JZRCR-YPP01 – Yaskawa Programming Pendant Assembly
- JZNC-YPS01 – Yaskawa Control Power Supply Unit
- JANCD-YBK01 – Yaskawa Brake Relay Board