Product Description
The Siemens 1FK7086-4CF71-1CH1 is a SIMOTICS S 1FK7 High Dynamic permanent-magnet synchronous servo motor designed for precision motion control in industrial automation, CNC machinery, and machine-tool applications. With a rated power of 2 kW and a rated speed of 3,000 rpm, it delivers a rated torque of 6.5 Nm and a static torque of 28 Nm at a 100 K temperature rise. The motor features natural cooling, an absolute AM24DQI encoder with DRIVE-CLiQ interface, a smooth shaft, and an integrated holding brake. Its IM B5 flange mounting design supports installation in compatible Siemens SINAMICS S120 drive systems. The motor is suitable for positioning, speed-control, and automated production applications requiring accurate feedback and controlled braking. The supplied listing describes the unit as renewed; buyers should confirm the refurbishment scope, brake operation, encoder feedback, and electrical test results before installation.

Key Product Parameters
- Brand: Siemens
- Model: 1FK7086-4CF71-1CH1
- Series: SIMOTICS S 1FK7 High Dynamic
- Product Name: Permanent-Magnet Synchronous Servo Motor
- Rated Power: 2 kW
- Rated Speed: 3,000 rpm
- Rated Torque: 6.5 Nm at 100 K temperature rise
- Static Torque: 28 Nm at 100 K temperature rise
- Rated Current: 5.7 A
- Maximum Permissible Mechanical Speed: 6,000 rpm
- Maximum Torque: 105 Nm
- Maximum Current: 115 A
- DC Link Voltage Class: 600 V
- Number of Poles: 8
- Encoder: AM24DQI absolute encoder
- Encoder Resolution: 24-bit single-turn plus 12-bit multi-turn
- Encoder Interface: DRIVE-CLiQ
- Holding Brake: Integrated permanent-magnet holding brake
- Shaft Type: Plain shaft, tolerance N
- Cooling: Natural cooling
- Mounting Design: IM B5 (IM V1, IM V3)
- Frame Size: 80 mm shaft height
- Protection Rating: IP65
- Temperature Monitoring: Pt1000 temperature sensor
- Electrical Connection: Rotatable power and signal connectors
- Moment of Inertia: 25 kg·cm²
- Efficiency: 93%
- Weight: Approximately 26 kg
- Dimensions: Verify against the Siemens mechanical drawing for the exact installation configuration
- Place of Manufacture: Not confirmed; check the motor nameplate
- Country of Origin: Not confirmed
- Product Status: Renewed / Refurbished, as stated in the supplied listing
- Power Requirements: Compatible Siemens SINAMICS servo drive system; 600 V DC link voltage class, not a direct mains connection
- Discontinued Status: Confirm current lifecycle status with Siemens using the complete order number
Operating Procedures and Usage Instructions
1. Installation Preparation
- Verify the complete motor order number, 1FK7086-4CF71-1CH1.
- Check the nameplate and compare its electrical and mechanical specifications with the original motor.
- Confirm compatibility with the SINAMICS S120 drive and the installed DRIVE-CLiQ interface.
- Inspect the shaft, flange, connectors, housing, and brake assembly.
- Check the encoder connector and confirm that the feedback system is recognized by the drive.
- Verify the holding-brake specifications and release arrangement.
- Isolate the electrical supply before installation.
2. Mechanical and Electrical Installation
- Mount the motor using the specified IM B5 flange arrangement.
- Check shaft alignment and coupling compatibility.
- Secure the motor with the recommended mounting hardware.
- Connect the power cable to the compatible Siemens drive output.
- Connect the DRIVE-CLiQ feedback cable to the designated interface.
- Connect the protective grounding conductor.
- Verify cable shielding, connector locking, and mechanical clearance.
- Confirm that the holding brake is connected to the approved brake-control circuit.
3. Power-On and Commissioning
- Verify the drive power supply and control connections.
- Restore power according to the machine manufacturer’s startup sequence.
- Confirm that the drive recognizes the AM24DQI encoder.
- Check motor identification and the stored drive parameters.
- Verify the holding-brake control and release function.
- Perform a low-speed test under controlled conditions.
- Check rotation direction, actual speed, motor current, and feedback stability.
- Gradually increase the operating load while monitoring temperature and drive diagnostics.
4. Normal Operation
- Enable the servo motor through the machine control system.
- Monitor commanded and actual motor speed.
- Check torque demand and current consumption.
- Monitor the encoder feedback and DRIVE-CLiQ communication status.
- Confirm that the holding brake releases correctly during operation.
- Observe motor temperature, vibration, and operating noise.
- Keep the motor within its rated operating limits.
5. Parameter Configuration and Modification
- Use the appropriate Siemens SINAMICS commissioning environment.
- Back up the existing drive parameters before making changes.
- Confirm the complete motor identification data and encoder configuration.
- Verify speed limits, current limits, torque settings, and brake-control parameters.
- Check the DRIVE-CLiQ communication configuration.
- Do not copy parameters from another 1FK7 motor without verifying its complete order number.
- Perform controlled positioning and speed tests after configuration changes.
6. Shutdown Procedure
- Stop machine movement and bring the motor to a safe standstill.
- Disable the servo drive through the machine control system.
- Apply the holding brake according to the approved sequence.
- Switch off the drive power supply.
- Isolate the electrical supply and observe the specified DC-link discharge time.
- Verify that hazardous voltage is absent before servicing the motor or drive cables.
Daily Maintenance
- Inspect the motor housing and flange for damage or contamination.
- Check the shaft and coupling for abnormal vibration or mechanical wear.
- Inspect power and DRIVE-CLiQ connectors for loose connections.
- Monitor motor temperature and operating current.
- Check encoder communication and feedback stability.
- Verify holding-brake operation during scheduled maintenance.
- Inspect cable insulation, grounding, and shielding.
- Keep the motor surface clean to support natural cooling.
- Record drive alarms and maintenance findings.
- Maintain backups of motor and drive configuration data.
Troubleshooting
1. Motor Does Not Start
Check the drive enable signal, power supply, motor connections, and control-system status. Verify that the motor identification data has been configured correctly.
2. DRIVE-CLiQ or Encoder Alarm
Inspect the feedback cable, connector pins, shielding, and network configuration. Confirm that the AM24DQI encoder is correctly recognized.
3. Holding Brake Does Not Release
Check the brake-control circuit, supply voltage, control signal, and brake wiring. Do not force the motor shaft while the brake is engaged.
4. Motor Overheating
Check the mechanical load, current demand, ambient temperature, and cooling conditions. Verify that the motor is operating within its rated duty.
5. Excessive Vibration or Noise
Inspect shaft alignment, coupling condition, mounting bolts, and mechanical load. Check the feedback signal and drive tuning.
6. Positioning Accuracy Problems
Verify encoder communication, motor identification, mechanical backlash, and drive parameters. Compare commanded and actual position values.
Safety Precautions
- Installation and commissioning must be performed by qualified servo-drive technicians.
- Isolate electrical power before connecting or disconnecting motor cables.
- Observe the specified DC-link discharge time and verify safe voltage levels before servicing.
- Never connect the motor directly to the mains supply.
- Confirm motor and SINAMICS drive compatibility before startup.
- Use the correct DRIVE-CLiQ cable and connector arrangement.
- Ensure that the holding brake is controlled through the approved circuit.
- Keep personnel clear of rotating shafts and mechanical couplings.
- Do not exceed the specified maximum mechanical speed.
- Perform initial testing at reduced speed and load.
Product Keywords
Siemens 1FK7086-4CF71-1CH1, SIMOTICS S servo motor, Siemens 1FK7 High Dynamic, 2 kW servo motor, 3000 rpm synchronous motor, 6.5 Nm servo motor, 28 Nm static torque, AM24DQI encoder, DRIVE-CLiQ motor, Siemens SINAMICS S120, integrated holding brake, industrial CNC servo motor, refurbished Siemens motor, industrial automation spare parts.
Product information: https://www.newplcdcs.com
15 Related Siemens Servo Motor Models
The following models are related Siemens SIMOTICS S 1FK7 servo motor references. They are useful for spare-parts research but are not guaranteed direct replacements.
- 1FK7086-4CF71-1CH1 – Exact 2 kW, 3,000 rpm Servo Motor
- 1FK7086-4CF71-1CH2 – 1FK7 High Dynamic Motor Variant
- 1FK7086-4CF71-1QA1 – 1FK7 High Dynamic Motor Variant
- 1FK7086-4CC71-1CH1 – 1FK7 Servo Motor, 2,000 rpm Variant
- 1FK7086-4SF71-1CH1 – 1FK7 High Dynamic Motor Variant
- 1FK7085-4CF71 – 1FK7 High Dynamic Servo Motor Family
- 1FK7084-3BC71 – 1FK7 Synchronous Servo Motor Family
- 1FK7083-2AF71 – 1FK7 Synchronous Servo Motor Family
- 1FK7083-2AF74 – 1FK7 Servo Motor Family
- 1FK7101 – SIMOTICS S 1FK7 Servo Motor Family
- 1FK7103 – SIMOTICS S 1FK7 Servo Motor Family
- 1FK7063 – SIMOTICS S 1FK7 Servo Motor Family
- 1FK7064 – SIMOTICS S 1FK7 Servo Motor Family
- 1FT7086 – Siemens SIMOTICS S Servo Motor Family
- 1FT7105 – Siemens SIMOTICS S Servo Motor Family
Always verify the complete Siemens order number, encoder type, holding-brake configuration, shaft design, mounting dimensions, and drive compatibility before selecting a replacement.