Product Description
The AMK PUMASYN PUS15/20-E Pulse Inverter, part number 44388-9241-511384, is an industrial power conversion unit designed for motor drive applications. It belongs to the AMK PUMASYN inverter family and is intended for use in compatible machine-tool and industrial motion-control systems. Available technical references for the PUS15/20-E family identify a 400 V-class input supply and an output voltage of approximately 330 V, with a stated output frequency range of up to 1,000 Hz. A related technical listing specifies a 26 A nominal output current and a maximum of 35 A; these ratings should be confirmed against the exact nameplate and applicable manual before installation. The unit is suitable for maintenance, repair, and restoration projects where the original AMK drive configuration must be retained. Confirm the complete part number, electrical ratings, control connections, and machine-specific configuration before ordering or commissioning.

Technical Specifications
- Brand: AMK
- Model: PUS15/20-E
- Part Number: 44388-9241-511384
- Series: PUMASYN
- Product Name: Pulse Inverter
- Product Type: Industrial motor inverter / pulse drive
- Place of Manufacture: Not verified
- Product Status: Used; seller listing identifies the item as pre-owned
- Dimensions: Not verified; consult the product dimensional drawing
- Weight: Not verified
- Country of Origin: Not verified; check the product nameplate
- Input Voltage: 400 V AC class, subject to nameplate confirmation
- Input Frequency: 50/60 Hz, subject to nameplate confirmation
- Output Voltage: Approximately 330 V, family-level reference
- Output Current: 26 A nominal and up to 35 A maximum are reported for the PUS15/20-E family; verify the exact unit rating
- Output Frequency: Up to 1,000 Hz, family-level reference
- Discontinued: The PUS15/20-E is identified as discontinued in a secondary industrial parts reference; confirm current manufacturer support and spare-parts availability
Operating Procedures
1. Preparation
- Check the nameplate for the complete model and serial number.
- Compare the input voltage, frequency, output ratings, and terminal markings with the original machine documentation.
- Inspect the enclosure, power terminals, control connectors, cooling passages, and grounding points.
- Verify that the motor and load are compatible with the inverter’s electrical ratings.
- Confirm that the machine’s emergency-stop and external protection circuits are functional.
2. Installation
- Install the inverter in the specified cabinet or mounting location.
- Maintain the required ventilation clearances and environmental conditions stated in the applicable manual.
- Secure the unit using the specified mounting hardware.
- Connect protective earth according to the machine’s electrical design.
- Keep power wiring separated from low-level control and feedback wiring where required.
3. Electrical Connection
- Connect the incoming supply only after confirming the correct terminal assignments and supply ratings.
- Connect motor output conductors according to the original wiring diagram.
- Check motor cable condition, insulation, grounding, and phase connections.
- Connect enable, interlock, speed reference, and feedback signals only after verifying their electrical characteristics.
- Do not assume that terminal layouts from other PUS15/20 variants are identical.
4. Power-On
- Confirm that all wiring and protective covers are installed.
- Check the cabinet grounding and supply protection.
- Energize the unit using the machine manufacturer’s prescribed sequence.
- Observe status indicators and diagnostic messages.
- Do not enable motor output until the control system reports the required ready condition.
5. Normal Operation
- Monitor motor speed, current, operating temperature, and drive status.
- Check for abnormal vibration, noise, overheating, or unexpected motor response.
- Verify that speed commands and feedback signals agree with the machine’s control logic.
- Record alarms and operating conditions for maintenance review.
6. Configuration
- Use the original AMK documentation and machine-specific parameter records.
- Confirm motor data, control mode, speed limits, acceleration and deceleration settings, and protection thresholds.
- Back up existing parameters before making changes.
- Do not load parameter sets from another inverter without confirming hardware and firmware compatibility.
7. Shutdown
- Remove the run or enable command using the machine’s normal stop sequence.
- Wait for the motor and DC bus to reach the safe state specified by the manufacturer.
- Isolate the incoming power supply before electrical inspection or maintenance.
- Verify the absence of hazardous voltage using an appropriately rated measuring instrument.
Daily Maintenance
- Check the inverter for abnormal noise, smell, vibration, or excessive temperature.
- Inspect cabinet ventilation openings and cooling passages for dust accumulation.
- Confirm that cooling fans, if fitted, operate correctly.
- Check for loose terminals, damaged insulation, and signs of overheating during scheduled inspections.
- Review drive alarms and machine fault history.
- Keep the cabinet dry, clean, and within the specified operating environment.
- Maintain a backup of verified drive parameters and machine wiring records.
- Arrange periodic inspection of capacitors, fans, and other age-sensitive components according to the manufacturer’s maintenance guidance.
Troubleshooting
1. Inverter does not power up
- Check the incoming supply and protective devices.
- Verify the control supply and external interlocks.
- Inspect connectors and terminal wiring.
- If the supply is correct but the unit remains inactive, arrange qualified drive-level diagnosis.
2. Motor does not start
- Check the run-enable signal and emergency-stop circuit.
- Confirm that the inverter is in the ready state.
- Check motor connections and the control-system command.
- Review active fault messages before attempting another start.
3. Motor speed is incorrect
- Verify the speed reference source and scaling.
- Check motor data and parameter settings.
- Inspect feedback wiring, if used.
- Confirm that configured speed limits match the machine requirements.
4. Overcurrent or drive trip
- Inspect the motor cable and motor terminals for short circuits or ground faults.
- Check for mechanical binding or excessive load.
- Verify that acceleration and deceleration settings are appropriate.
- Do not repeatedly reset the inverter without identifying the cause.
5. Overtemperature
- Check cabinet ventilation and ambient temperature.
- Clean blocked cooling passages after isolating power.
- Inspect cooling fans and cabinet filters, if fitted.
- Check whether the motor or machine is operating beyond its specified load.
6. Intermittent operation
- Inspect power and control terminals for loose connections.
- Check grounding and cable routing.
- Review alarm history for supply fluctuations or intermittent interlock signals.
- Verify that the control wiring matches the original machine design.
Safety Precautions
- Installation, commissioning, and repair must be performed by qualified industrial electrical personnel.
- Isolate and lock out all power sources before opening the cabinet or touching electrical connections.
- Allow the DC bus to discharge for the time specified by the manufacturer and verify the voltage before servicing.
- Never connect or disconnect motor cables while the inverter is energized.
- Use the specified protective devices, conductor sizes, grounding method, and cable types.
- Do not exceed the inverter’s verified voltage, current, frequency, or environmental ratings.
- Do not bypass emergency-stop circuits, interlocks, or protective functions.
- Use the complete model code and original documentation to confirm compatibility before replacing an existing unit.
Product Keywords
AMK PUS15/20-E, 44388-9241-511384, AMK PUMASYN, AMK pulse inverter, industrial inverter, motor drive, AC drive, machine tool drive, industrial automation spare parts, AMK drive replacement, power conversion unit.
For product information and industrial automation spare parts, visit https://www.newplcdcs.com.
Related AMK Models and Product Families
The following are related AMK drive models and product families for identification and sourcing research. They are not confirmed drop-in replacements for the PUS15/20-E.
- AMK PUS15/20-I – PUMASYN pulse inverter variant
- AMK PUS8/11-I – PUMASYN pulse inverter
- AMK PUS25/32R – DC axis drive
- AMK PUS3-1 – Pulse inverter family
- AMK PUS3/5 – Pulse inverter family
- AMK AMKASYN AZ05 – Digital inverter family
- AMK AMKASYN AZ20 – Digital inverter family
- AMK AMKASYN AZ60 – Digital inverter family
- AMK AMKASYN AW2/4-3 – Servo drive family
- AMK AMKASYN AW3/6 – Servo drive family
- AMK AMKASYN KW8 – Drive axis module
- AMK AMKASYN KW20 – Drive axis module
- AMK AMKASYN KW-R03 – Drive axis module
- AMK AMKASYN KU3 – Drive system family
- AMK AMKASYN KU25-1 – Servo drive family