Product Description
The Bently Nevada 1701/15 FieldMonitor Proximitor Input Monitor is a two-channel machinery protection module designed for monitoring shaft vibration, radial position, and axial thrust position in industrial rotating equipment. It receives signals from compatible proximity probes through an associated transducer I/O module or internal Proximitor module, converts the signals into engineering measurements, and compares measured values against programmable alarm setpoints. The module provides Alert and Danger alarm functions, measurement outputs for host control systems, and built-in self-diagnostics to identify monitor or transducer faults. Designed for the Bently Nevada 1701 FieldMonitor distributed monitoring architecture, it is suitable for applications involving turbines, compressors, pumps, motors, and other critical rotating machinery.

Key Technical Specifications
- Brand: Bently Nevada
- Model: 1701/15
- Product Series: FieldMonitor 1701
- Product Name: Proximitor Input Monitor
- Product Type: Two-channel machinery protection monitor
- Input Type: Proximity transducer signals
- Number of Channels: 2
- Measurement Functions: Radial vibration, radial shaft position, and axial thrust position
- Signal Processing: Direct vibration and gap measurement
- Programmable Values: Direct (Overall) and Gap
- Alarm Functions: Alarm 1 (Alert) and Alarm 2 (Danger)
- Alarm Behavior: Non-latching
- Alarm Delay Options: 0.15 to 20 seconds, selectable
- Direct Measurement Accuracy: 1% of full scale maximum, excluding filters
- Direct Resolution: 0.1% of full scale
- Gap Accuracy: ±20 mV over the -1 to -23 V range
- Gap Resolution: 1 mV
- Setpoint Resolution: 0.5% of full scale
- Power Input: -24 V and +5 V from the FieldMonitor power supply
- Power Consumption: Approximately 1.5 W, excluding transducers
- Buffered Output Impedance: 200 Ω
- Operating Temperature: -20 to +70°C
- Storage Temperature: -40 to +85°C
- Operating Humidity: 5% to 95%, non-condensing
- Dimensions: Approximately 127 × 21.6 × 105 mm
- Weight: Approximately 314 g
- System Compatibility: Bently Nevada 1701 FieldMonitor architecture
- Product Status: Legacy FieldMonitor series
- Country of Origin: Verify on the individual unit label
Installation and Operating Instructions
- Verify the 1701/15 model number and inspect the module label and hardware revision.
- Confirm compatibility with the existing Bently Nevada FieldMonitor system.
- Select the appropriate terminal base, either 1701/05 or 1701/06, according to the installation and hazardous-area requirements.
- Confirm that the associated transducer I/O or internal Proximitor module matches the installed probe type.
- Isolate the system power before installing or removing the monitor.
- Mount the module securely and verify its connection to the terminal base.
- Connect the proximity probes and associated transducer wiring according to the system drawings.
- Configure measurement type, alarm setpoints, alarm delays, and channel assignments using the applicable FieldMonitor configuration tools.
- Verify probe gap voltage and signal scaling before enabling machinery protection alarms.
- Check monitor diagnostics, channel status, and host-system communication.
- Perform a controlled functional test and confirm that Alert, Danger, and NOT OK indications are correctly reported.
Daily Maintenance
- Inspect the module and terminal base for loose connections or physical damage.
- Check proximity probe cables and connectors for wear or interference.
- Monitor channel readings for abnormal vibration or shaft-position changes.
- Review Alert, Danger, and NOT OK indications.
- Check probe gap voltage and signal stability.
- Inspect cabinet temperature and environmental conditions.
- Verify the integrity of the FieldMonitor power supply.
- Review alarm history and investigate recurring channel faults.
- Confirm that configuration backups and alarm settings are maintained.
Troubleshooting and FAQ
Q1: The monitor reports a NOT OK condition.
Check the monitor diagnostics, transducer wiring, probe condition, and associated I/O module. A NOT OK indication may result from a monitor fault or a problem with the connected transducer.
Q2: The vibration reading is unstable.
Inspect the proximity probe, extension cable, connector, grounding, and shielding. Check for electrical interference and mechanical vibration sources.
Q3: The gap voltage is outside the expected range.
Check probe installation, target clearance, probe cable compatibility, and transducer configuration. Verify the gap voltage using the correct measurement procedure.
Q4: Can the 1701/15 monitor both vibration and shaft position?
Yes. The same channel can provide direct radial vibration and gap/shaft-position measurements. Gap measurements normally provide Alarm 1 capability only.
Q5: Does the 1701/15 connect directly to every proximity probe?
Not necessarily. The monitor requires a compatible transducer I/O module or internal Proximitor module. Verify probe series, cable length, signal characteristics, and I/O module selection.
Q6: Which terminal base is required?
The 1701/05 standard terminal base is used for applicable non-hazardous or externally protected installations. The 1701/06 isolator terminal base is used with the 170190 dual galvanic isolator for specified intrinsically safe applications.
Q7: Can the 1701/15 replace a Bently Nevada 1701/25?
No direct replacement should be assumed. The 1701/15 measures proximity-probe signals, while the 1701/25 is a seismic input monitor. Their sensor inputs and measurement functions differ.
Safety Precautions
- Installation and maintenance must be performed by qualified instrumentation personnel.
- Isolate power before removing or installing the monitor.
- Verify terminal-base and transducer compatibility before connecting field wiring.
- Follow the approved hazardous-area installation drawings and certification requirements.
- Do not bypass machinery protection alarms without an approved maintenance procedure.
- Verify probe gap voltage and alarm settings before returning equipment to service.
- Use appropriate shielding and grounding practices to reduce electrical interference.
- Confirm that the host control system correctly receives alarm and NOT OK signals.
- Never assume that a standard terminal base provides intrinsic safety protection.
Related Bently Nevada Models and Components
The following products belong to the Bently Nevada 1701 FieldMonitor system and related machinery monitoring families. They are associated system components or alternative measurement modules, not guaranteed direct replacements:
- 1701/05-01 – FieldMonitor Standard Terminal Base
- 1701/06-01 – FieldMonitor Isolator Terminal Base
- 1701/10-01 – FieldMonitor 24 V DC Power Supply
- 1701/22-01 – FieldMonitor Management Interface Module
- 1701/25-01 – FieldMonitor Seismic Input Monitor
- 1701/30-01 – FieldMonitor Dynamic Pressure Monitor
- 1701/50 – FieldMonitor Weatherproof Housing
- 170133 – Internal 3300 Proximitor Module
- 170150 – Internal 3300 NSv Proximitor Module
- 170172 – Internal 7200 Proximitor Module
- 170180-01 – Proximitor/Accelerometer I/O Module
- 170180-02 – Dual Velocity I/O Module
- 170180-03 – Dual Velomitor I/O Module
- 170190-01 – Dual Galvanic Isolator
- 170190-02 – Dual Galvanic Isolator for CEC Velocity Applications
Always verify transducer compatibility, terminal-base type, power requirements, hazardous-area certification, and FieldMonitor system configuration before selecting associated components.
Product Keywords
Bently Nevada 1701/15, 1701/15 FieldMonitor, Proximitor Input Monitor, Bently Nevada Vibration Monitor, Two-Channel Vibration Monitor, Shaft Vibration Monitoring, Axial Thrust Position, Radial Shaft Position, Machinery Protection System, Proximity Probe Monitor, Turbine Monitoring, Compressor Protection, Industrial Condition Monitoring, Bently Nevada Spare Parts.
For industrial automation and machinery protection spare parts, visit https://www.newplcdcs.com.