Product Description
The Bosch Rexroth Indramat HVR02.2-W025N (R911276575) is a high-power regenerative supply unit designed for DIAX04 industrial drive systems. It converts three-phase AC input power into a regulated 750 VDC intermediate circuit supply for connected servo drives and motion control equipment. The unit supports an input voltage of 3 × 380–480 VAC and delivers 25 kW continuous DC bus power, with peak output power of 75 kW for 0.3 seconds. Its regenerative capability returns excess braking energy to the electrical mains, reducing energy dissipation during dynamic motor operation. The integrated blower provides internal air cooling, while the front-panel status display supports operational monitoring and fault diagnosis. Designed for centralized power distribution in multi-axis automation systems, the HVR02.2-W025N is suitable for CNC machinery, industrial presses, packaging equipment, machine tools, and automated production lines. It is compatible with appropriately configured Rexroth Indramat DIAX04 drive systems. Before replacement or commissioning, verify the complete type code, electrical ratings, system configuration, firmware compatibility, and installation requirements.

Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | Bosch Rexroth Indramat |
| Model | HVR02.2-W025N |
| Part Number | R911276575 |
| Series | HVR Power Supply Units |
| Product Name | Regenerative Power Supply Unit |
| Product Type | Second-Generation Power Supply |
| Place of Manufacture | Not independently verified |
| Product Status | Not specified in supplied listing |
| Dimensions | Approx. 498 × 175 × 262 mm (H × W × D) |
| Weight | Approx. 21 kg |
| Country of Origin | Not independently verified |
| Power Requirements | 3 × 380–480 VAC ±10% |
| Input Frequency | 50–60 Hz ±2 Hz |
| DC Bus Voltage | 750 VDC |
| Continuous Output Power | 25 kW |
| Peak Output Power | 75 kW for 0.3 seconds |
| Cooling Method | Internal air cooling with built-in blower |
| Protection Rating | IP10 |
| Operating Temperature | 5 to 45°C at rated load |
| System Compatibility | Rexroth Indramat DIAX04 |
| Discontinued | Legacy product; confirm lifecycle status with manufacturer |
⚙️ Operating Procedures and Usage Instructions
1. Installation and Preparation
- Verify the model number HVR02.2-W025N and part number R911276575.
- Inspect the housing, cooling fan, terminals, and front-panel display.
- Install the power supply in a suitable industrial electrical cabinet.
- Maintain the manufacturer’s specified ventilation clearances.
- Connect the three-phase AC input according to the wiring diagram.
- Connect protective earth (PE).
- Connect the DC bus to compatible DIAX04 drive modules.
- Verify control voltage connections and communication interfaces.
- Check the input voltage, phase sequence, and external protection devices.
- Confirm that the cabinet cooling system can handle the unit’s heat dissipation.
2. Power-On Sequence
- Confirm that all connected servo drives are disabled.
- Check the three-phase input voltage and protective grounding.
- Verify AC input terminals and DC bus connections.
- Confirm that all connected drive modules are correctly installed.
- Check the emergency-stop and machine safety circuits.
- Energize the auxiliary control supply according to the system design.
- Apply the main three-phase AC supply.
- Allow the HVR power supply to complete its initialization.
- Check the front-panel seven-segment display for status or fault indications.
- Verify that the DC bus reaches its nominal operating voltage.
- Enable connected servo drives according to the machine commissioning procedure.
Do not repeatedly switch the supply on and off. Observe the manufacturer’s specified power-cycle intervals and startup requirements.
3. Normal Operating Procedure
- Confirm that the HVR02.2-W025N reports normal operating status.
- Verify the DC bus voltage.
- Check communication with the connected DIAX04 drive system.
- Enable the required servo drive modules.
- Start the machine controller.
- Execute a low-speed motor test.
- Check motor direction, acceleration, and positioning.
- Start the automatic production process.
- Monitor DC bus voltage, input conditions, and power supply temperature.
- Check for overload, overvoltage, and regeneration-related alarms.
- Stop the machine if abnormal operating conditions occur.
4. Parameter Configuration and Modification
- Use compatible Rexroth Indramat commissioning software and system documentation.
- Verify the installed DIAX04 system configuration.
- Read and back up the existing drive parameters before modification.
- Check the connected drive modules and DC bus power requirements.
- Verify the rated 25 kW continuous output capacity.
- Check the 750 VDC intermediate circuit configuration.
- Confirm that regenerative energy handling is compatible with the connected motors and mechanical loads.
- Verify motor parameters, acceleration limits, and deceleration settings in the individual drive controllers.
- Check the power supply status and fault history.
- Save the approved configuration and perform a controlled commissioning test.
The HVR02.2-W025N is a power supply unit, not an independent motion controller. Motor speed, torque, and positioning parameters are configured through the connected drive controllers.
5. Shutdown Sequence
- Stop the automatic production cycle.
- Command all connected servo axes to decelerate.
- Confirm that all motors have stopped.
- Disable the servo drive enable signals.
- Verify that the mechanical loads are in a safe condition.
- Switch off the main AC supply according to the machine shutdown procedure.
- Isolate the auxiliary supply when required.
- Allow the DC bus capacitors to discharge.
- Measure the DC bus voltage before accessing electrical terminals.
- Apply lockout/tagout procedures before maintenance.
Never assume that the DC bus is discharged immediately after switching off the mains supply.
🔧 Daily Maintenance and Troubleshooting
- Inspect the cooling blower for abnormal noise or vibration.
- Clean air intake and exhaust passages regularly.
- Check AC input and DC bus terminals for overheating or looseness.
- Monitor the front-panel status display.
- Check the DC bus voltage during normal operation.
- Inspect grounding connections and cabinet ventilation.
- Investigate overvoltage and undervoltage alarms.
- Check regenerative energy conditions during motor deceleration.
- Inspect the connected servo drives for communication or power faults.
- Record recurring fault codes and operating conditions.
- Replace defective cooling components with compatible approved parts.
⚠️ Safety Precautions
- Installation and maintenance must be performed by qualified electrical personnel.
- The unit operates with hazardous three-phase AC and high-voltage DC.
- Never disconnect power connections while energized.
- Observe the manufacturer’s DC bus discharge requirements.
- Verify zero hazardous voltage before electrical maintenance.
- Provide appropriate upstream fuses and circuit protection.
- Do not exceed the specified continuous or peak output ratings.
- Ensure sufficient cabinet ventilation.
- The IP10 enclosure rating does not provide protection against water or fine dust.
- Do not use the power supply’s regenerative function as a substitute for an approved emergency-stop braking system.
- Never bypass machine safety circuits.
🔗 Product Keywords and Information
Bosch Rexroth Indramat HVR02.2-W025N, R911276575, HVR Power Supply, 25 kW Regenerative Power Supply, DIAX04 Power Supply Unit, 750 VDC DC Bus, 380–480 VAC, Industrial Servo Drive Power Supply, Regenerative Energy Recovery.
For industrial automation components and Rexroth Indramat replacement parts, visit:
Recommended Bosch Rexroth Indramat Models
- HVR02.2-W010N – 10 kW Regenerative Power Supply
- HVR02.2-W025N – 25 kW Regenerative Power Supply
- HVR03.2-W045N – 45 kW Regenerative Power Supply
- HVR02.2-W010 – HVR Power Supply Unit
- HVR02.2-W025N/S200 – HVR Power Supply Unit
- HVR02.2-W025N/S201 – HVR Power Supply Unit
- HVR02.2-W025N/S202 – HVR Power Supply Unit
- HVR02.2-W025N/S203 – HVR Power Supply Unit
- HVR02.2-W025N/S204 – HVR Power Supply Unit
- HVE02.2-W018N – HVE Power Supply Unit
- HVE03.2-W030N – HVE Power Supply Unit
- HDS02.2-W040N – DIAX04 Drive Controller
- HDS03.2-W100N – DIAX04 Drive Controller
- DDS02.1-W050 – Digital Drive Controller
- DDS03.2-W030 – Digital Drive Controller