Product Description
The Bosch Rexroth Indramat HVR03.1-W045N (R911272144) is a high-power regulated DC bus supply module designed for DIAX04 industrial drive systems. It converts three-phase AC mains power into a regulated DC bus supply for connected HDS and HDD drive controllers, supporting coordinated operation of multiple servo axes. With a nominal continuous DC bus power rating of 45 kW and peak output capability of 135 kW for 0.3 seconds, this power supply is suitable for demanding motion control applications involving frequent acceleration, deceleration, and regenerative braking. The unit supports energy regeneration and includes an integrated bleeder circuit for handling specified braking and emergency-stop energy. Its internal blower cooling system helps maintain operating temperature inside an appropriately ventilated control cabinet. Typical applications include CNC machine tools, industrial presses, automated production lines, metal processing equipment, and multi-axis servo drive systems. Before replacement or commissioning, verify the mains voltage, DC bus configuration, connected drive modules, electrical connections, cooling requirements, and complete material number.

📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | Bosch Rexroth / Indramat |
| Model | HVR03.1-W045N |
| Material Number | R911272144 |
| Series | DIAX04 HVR Power Supply |
| Product Name | Regulated DC Bus Power Supply Unit |
| Product Group | HVR03 |
| Design Version | 1 |
| Input Voltage | 3 × 380–480 V AC (±10%) |
| Input Frequency | 50–60 Hz (±2 Hz) |
| DC Bus Voltage | 750 V DC |
| Continuous DC Bus Power | 45 kW |
| Peak DC Bus Power | 135 kW for 0.3 seconds |
| Short-Time DC Bus Power | 105 kW for 3 seconds |
| Continuous Regenerative Power | 30 kW |
| Peak Regenerative Power | 90 kW |
| Maximum Regenerated Energy | 100 kWs |
| Bleeder Peak Power | 80 kW |
| Control Voltage Output | 500 W |
| Cooling Method | Internal air cooling with integrated blower |
| Protection Rating | IP10 |
| Dimensions | Approx. 498 × 250 × 262 mm; verify exact version drawing |
| Weight | Approx. 24 kg |
| Operating Temperature | +5°C to +45°C at rated conditions |
| Maximum Ambient Temperature | +55°C with derating |
| Installation | Closed control cabinet or suitable enclosure |
| Country of Origin | Germany; verify individual unit nameplate |
| Product Status | Refurbished, according to seller description |
| Discontinued | Legacy DIAX04 product; current lifecycle status requires manufacturer confirmation |
⚙️ Operating Procedures and Usage Instructions
1. Installation and Preparation
- Inspect the power supply housing, cooling fan, terminals, DC bus connections, and mounting points.
- Verify the R911272144 material number and HVR03.1-W045N model.
- Confirm compatibility with the connected DIAX04 HDS and HDD drive controllers.
- Install the module in the specified control cabinet mounting position.
- Ensure sufficient ventilation and unobstructed airflow.
- Verify the three-phase AC supply voltage and protective grounding.
- Connect the mains input according to the official wiring diagram.
- Connect the DC bus to compatible drive modules using approved bus connections.
- Check the control voltage and monitoring connections.
- Verify that the emergency-stop and regenerative energy handling circuits are correctly configured.
2. Power-On Sequence
- Confirm that all drive controllers and motor connections are correctly installed.
- Check the AC mains voltage and phase sequence.
- Verify DC bus connections and protective grounding.
- Ensure all connected servo axes are in a safe condition.
- Switch on the control and auxiliary supply according to the system design.
- Energize the main three-phase supply using the specified switching arrangement.
- Allow the HVR power supply to initialize.
- Check the module status display and diagnostic indicators.
- Verify that the DC bus reaches its specified operating voltage.
- Enable the connected drive controllers only after the supply system reports normal operation.
3. Normal Operating Procedure
- Confirm that the HVR03.1-W045N is operating without fault indications.
- Verify the DC bus voltage and connected drive controller status.
- Check cooling fan operation and cabinet ventilation.
- Enable the connected HDS/HDD servo drive controllers.
- Start the machine at reduced speed or load during initial verification.
- Monitor DC bus voltage, current, and power consumption.
- Observe regenerative energy during deceleration.
- Check for abnormal temperature, fan noise, or electrical alarms.
- Increase the machine load within the rated operating limits.
- Record operating conditions and diagnostic information.
4. Parameter Configuration and Modification
- Connect to the compatible DIAX04 drive system using the approved Bosch Rexroth commissioning equipment.
- Back up the existing drive and system configuration.
- Verify the HVR03.1-W045N supply identification.
- Check the mains supply configuration and DC bus settings.
- Verify the connected drive controllers and their power requirements.
- Review the regenerative energy and bleeder configuration.
- Confirm the emergency-stop energy handling arrangement.
- Check drive controller parameters through the compatible engineering software.
- Do not modify internal power supply settings unless explicitly supported by the manufacturer’s documentation.
- Perform a controlled restart and verify the DC bus and drive diagnostics after configuration changes.
5. Shutdown Sequence
- Stop the automatic machine cycle.
- Command all connected servo axes to decelerate to zero speed.
- Confirm that all motor movements have stopped.
- Disable the connected drive controllers according to the system procedure.
- Allow regenerative energy handling to complete.
- Switch off the main AC supply using the approved switching arrangement.
- Isolate auxiliary and control power as required.
- Wait for the manufacturer’s specified DC bus discharge time.
- Verify the DC bus voltage with an appropriately rated measuring instrument.
- Begin maintenance only after electrical isolation and safe voltage conditions have been confirmed.
🔧 Daily Maintenance and Troubleshooting
- Inspect the cooling fan and air intake for dust accumulation.
- Check AC input terminals and DC bus connections for discoloration or overheating.
- Monitor the DC bus voltage during operation.
- Investigate undervoltage and overvoltage alarms by checking the incoming supply and regenerative circuit.
- Check fan operation if thermal warnings occur.
- Inspect connected drive modules if DC bus faults appear.
- Check the bleeder circuit and regenerative energy handling components when braking faults occur.
- Verify protective grounding and electrical connections.
- Keep the cabinet clean and maintain adequate airflow.
- Record fault codes and operating conditions before replacing components.
⚠️ Safety Precautions
- Installation and maintenance must be performed by qualified high-voltage electrical technicians.
- The DC bus operates at approximately 750 V DC and presents a serious electric shock hazard.
- Never disconnect DC bus connections while energized.
- Observe the specified DC bus discharge waiting period.
- Always verify the actual DC bus voltage before servicing.
- Use suitable personal protective equipment and properly rated measuring instruments.
- Do not exceed the rated continuous or peak power limits.
- Maintain adequate ventilation around the integrated blower.
- Never bypass the emergency-stop or regenerative energy protection circuits.
- Follow the complete DIAX04 system safety and commissioning documentation.