Product Description
The Siemens 1FT7044-5AF71-1CH2 is a SIMOTICS S 1FT7 compact permanent-magnet synchronous servo motor designed for precision motion control in industrial automation systems. With a rated speed of 3,000 rpm, rated output power of approximately 1.35 kW, and rated torque of 4.3 Nm, this motor is suitable for applications requiring accurate positioning, controlled acceleration, and dynamic response. It features natural cooling, an IM B5 mounting configuration, a rotatable power connector, an AM24DQI absolute encoder with 24-bit single-turn and 12-bit multiturn resolution, and a plain shaft. The integrated permanent-magnet holding brake provides an 8 Nm holding torque and requires a separate 24 V DC brake supply. Designed for integration with compatible Siemens SINAMICS S120 drive systems, the motor is suitable for packaging machinery, machine tools, automated assembly equipment, and material handling systems. Its IP67 protection rating supports demanding industrial environments. Before installation, verify the motor identification, encoder interface, brake wiring, mechanical mounting, and SINAMICS drive compatibility.

📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | Siemens |
| Model | 1FT7044-5AF71-1CH2 |
| Series | SIMOTICS S 1FT7 Compact |
| Product Name | Permanent-Magnet Synchronous Servo Motor |
| Article Number | 1FT7044-5AF71-1CH2 |
| Rated Power | Approximately 1.35 kW |
| Rated Speed | 3,000 rpm |
| Rated Torque | 4.3 Nm |
| Maximum Mechanical Speed | 9,000 rpm |
| Maximum Torque | 23 Nm |
| Rated Current | 2.60 A |
| Cooling Method | Natural Cooling |
| Encoder | AM24DQI Absolute Encoder, 24-bit + 12-bit Multiturn |
| Feedback Interface | DRIVE-CLiQ |
| Shaft Type | Plain Shaft |
| Mounting Type | IM B5 |
| Holding Brake | Permanent-Magnet Brake |
| Holding Torque | 8 Nm |
| Brake Supply | 24 V DC |
| Protection Rating | IP67 |
| Temperature Sensor | Pt1000 |
| Dimensions | Compact frame, shaft height 48 mm; exact dimensions require drawing verification |
| Weight | 8.1 kg |
| Place of Manufacture | Germany |
| Country of Origin | Germany |
| Product Status | Unused, according to seller description; verify packaging and inspection condition |
| Discontinued | Exact lifecycle status requires Siemens confirmation |
⚙️ Operating Procedures and Usage Instructions
1. Installation and Preparation
- Inspect the motor housing, shaft, flange, connectors, and brake assembly.
- Confirm the complete model number and nameplate specifications.
- Verify compatibility with the Siemens SINAMICS S120 drive system.
- Check the motor mounting flange and shaft alignment.
- Secure the motor using the specified mounting hardware.
- Connect the motor power cable to the matching drive connector.
- Connect the DRIVE-CLiQ feedback cable to the compatible drive interface.
- Connect the 24 V DC holding brake supply according to the wiring diagram.
- Verify protective grounding and cable shielding.
- Ensure that the driven mechanical load is properly secured.
2. Power-On Sequence
- Confirm that the motor and connected machinery are mechanically secure.
- Check the three-phase drive power supply and electrical connections.
- Verify the 24 V DC brake supply.
- Switch on the control cabinet and auxiliary power.
- Power up the SINAMICS S120 drive system.
- Allow the drive to identify the connected motor and encoder.
- Check DRIVE-CLiQ communication and feedback status.
- Verify motor identification and brake configuration.
- Release the holding brake through the approved drive control sequence.
- Enable the servo and perform a low-speed movement test.
3. Normal Operating Procedure
- Load the approved motor and drive configuration.
- Verify the encoder feedback and actual motor position.
- Set the required speed, torque, and acceleration limits.
- Confirm the holding brake operates correctly.
- Execute a low-speed test movement.
- Check motor direction and positioning accuracy.
- Gradually increase the operating speed.
- Monitor current, torque, temperature, and drive diagnostics.
- Start the automatic machine sequence after commissioning checks pass.
- Record operating conditions and any drive alarms.
4. Parameter Configuration and Modification
- Connect to the SINAMICS S120 drive using the compatible Siemens STARTER or Startdrive engineering environment.
- Read and back up the existing drive configuration.
- Confirm the correct 1FT7044 motor identification.
- Verify the AM24DQI encoder and DRIVE-CLiQ configuration.
- Configure the motor speed and torque limits.
- Set acceleration and deceleration ramps according to the mechanical load.
- Configure the holding brake control and release timing.
- Check the motor temperature sensor configuration.
- Save the parameter set and perform a controlled test run.
- Do not transfer parameters from another motor variant without verifying its feedback and brake configuration.
5. Shutdown Sequence
- Stop the automatic machine cycle.
- Command the motor to decelerate to zero speed.
- Confirm that the motor shaft has stopped.
- Apply the holding brake through the approved drive sequence.
- Disable the servo enable signal.
- Shut down the SINAMICS drive system according to the machine procedure.
- Isolate the electrical supply before maintenance.
- Wait for the DC-link discharge period specified by the drive manufacturer.
- Verify electrical safety before disconnecting cables.
🔧 Daily Maintenance and Troubleshooting
- Inspect the motor housing and connectors for physical damage.
- Check the shaft coupling and mounting bolts.
- Monitor motor temperature during normal operation.
- Inspect DRIVE-CLiQ cables for loose connections.
- Check encoder feedback if positioning errors occur.
- Investigate overcurrent alarms by checking mechanical load and drive parameters.
- Check the holding brake if the motor cannot maintain its stationary position.
- Inspect cable shielding and grounding if feedback communication becomes unstable.
- Keep the motor surface clean and free from excessive contamination.
- Record operating hours, temperature changes, and maintenance findings.
⚠️ Safety Precautions
- Installation and commissioning must be performed by qualified electrical and automation personnel.
- Never connect or disconnect motor power cables while energized.
- Secure vertical or gravity-loaded axes before releasing the holding brake.
- The holding brake is designed for holding applications and should not be used as a routine dynamic stopping device unless specifically approved.
- Observe the SINAMICS drive DC-link discharge requirements.
- Do not exceed rated motor speed, torque, or current.
- Verify the encoder and brake wiring before commissioning.
- Maintain appropriate protective grounding and electrical isolation.
🔗 Product Keywords and Information
Siemens 1FT7044-5AF71-1CH2, SIMOTICS S 1FT7, Siemens Servo Motor, 1.35 kW Servo Motor, 3000 rpm Synchronous Motor, AM24DQI Encoder, DRIVE-CLiQ, SINAMICS S120, IP67 Servo Motor, Industrial Motion Control.
For Siemens servo motors, industrial automation equipment, and spare parts, visit:
Recommended Siemens Models
- 1FT7044-5AF70-1CB1 – SIMOTICS S Servo Motor
- 1FT7044-5AF71-1CA2 – SIMOTICS S Servo Motor
- 1FT7044-5AF71-1CH1 – SIMOTICS S Servo Motor
- 1FT7044-5AF71-1CH2 – SIMOTICS S Servo Motor
- 1FT7044-5AF71-1DA2 – SIMOTICS S Servo Motor
- 1FT7044-5AK71-1NG1 – SIMOTICS S Servo Motor
- 1FT7062-1AF71-1BH1 – SIMOTICS S Servo Motor
- 1FT7064-1AF71-1EH1 – SIMOTICS S Servo Motor
- 1FT7082-5AF71-1CH1 – SIMOTICS S Servo Motor
- 1FT7108-5WF71-1DH1 – SIMOTICS S Servo Motor
- 1FK7042-5AF71-1CH1 – SIMOTICS S Servo Motor
- 1FK7063-5AF71-1EH1 – SIMOTICS S Servo Motor
- 1FK7083-5AF71-1EH1 – SIMOTICS S Servo Motor
- 1FT7034-5AF71-1CH1 – SIMOTICS S Servo Motor
- 1FT7044-5AF71-1CA2 – SIMOTICS S Servo Motor
Note: These models belong to the Siemens SIMOTICS S servo motor portfolio. Encoder types, shaft designs, brake configurations, and mounting dimensions vary. Verify the complete article number before selecting a replacement.