Product Description
The Bosch Rexroth XM2200.01-01-31-31-301-NN-101NNNN, part number R911370638, is an IndraControl XM22 embedded controller designed for industrial PLC and motion-control applications. It combines an Intel Atom E660 processor operating at 1.30 GHz with 512 MB of application memory and 1 GB of mass storage. The controller supports centralized and decentralized automation architectures, with onboard Sercos communication and local connection of IndraControl S20 I/O modules through its bus base module. Its hardware configuration includes an S20 I/O expansion connection and an interface for XM functional extension modules. The controller provides Gigabit Ethernet, USB host, USB device, and an SD card slot for engineering and system maintenance. Its PLC and Motion Standard function package makes it suitable for machine sequencing, coordinated motion, drive communication, and distributed I/O management. The listed unit is marked 22W09, which should be treated as a date or production code pending confirmation from the product label, rather than a hardware revision.

Product Datasheet
- Brand: Bosch Rexroth
- Product Family: IndraControl XM22
- Model: XM2200.01-01-31-31-301-NN-101NNNN
- Material Number: R911370638
- Short Designation: XM2200
- Product Name: XM22 PLC and Motion Control Module
- Product Type: Embedded Industrial Controller
- Functional Package: PLC + Motion Standard
- Processor: Intel Atom E660
- Processor Clock Speed: 1.30 GHz
- Application Memory: 512 MB RAM
- Remanent Memory: 128 kB
- Mass Storage: 1 GB
- Supply Voltage: 24 VDC
- Permitted Supply Voltage Range: 18–31.2 VDC
- Residual Ripple: ±5%
- Onboard Fieldbus: Sercos Master
- Sercos Communication: Two RJ45 ports
- Engineering Interface: 1 × Gigabit Ethernet RJ45
- USB Interfaces: 1 × USB Host and 1 × USB Device
- Memory Card Interface: 1 × SD Card Slot
- Local I/O Expansion: IndraControl S20 modules
- Functional Expansion: XM XFE extension modules
- Optional Communication: PROFINET, EtherNet/IP, and PROFIBUS DP through compatible extension modules
- Maximum Operating Temperature: -25 to +60°C
- Storage Temperature: -30 to +85°C
- Protection Rating: IP20
- Protection Class: III
- Dimensions: 100 × 126.3 × 74.1 mm (W × H × D)
- Weight: Approximately 0.617 kg
- Product Marking: 22W09, as stated in the seller listing
- Country of Origin: Germany, according to supplier information
- Product Status: Verify current lifecycle and support availability with Bosch Rexroth
- Condition: Subject to seller confirmation
Operating Guidelines and Usage
- Verify that the installed automation system supports the IndraControl XM22 controller and the exact R911370638 configuration.
- Confirm the 24 VDC supply voltage, polarity, grounding, and power capacity before energizing the unit.
- Check the S20 bus base module and connected I/O modules for correct mechanical and electrical compatibility.
- Verify the two Sercos communication connections and the network topology used by the machine.
- Confirm that the required PLC and Motion Standard function package is available and supported by the installed engineering environment.
- Connect the engineering workstation through the Gigabit Ethernet interface using the approved network configuration.
- Check the controller diagnostics and communication status before enabling connected drives.
- Confirm that all local and decentralized I/O stations are correctly identified in the application configuration.
Power-On and Power-Off Sequence
Power-On
- Inspect the controller and bus base module for physical damage.
- Verify that all connected S20 modules and extension modules are installed correctly.
- Check the 24 VDC power supply and protective grounding.
- Apply power according to the Bosch Rexroth startup procedure.
- Allow the controller to complete its initialization process.
- Check diagnostic LEDs and controller status through the engineering interface.
- Verify Sercos communication and I/O availability.
- Enable connected drives only after the controller and safety-related system checks are complete.
Power-Off
- Stop the controlled machine using the approved shutdown procedure.
- Bring connected axes to a safe condition and disable drive enable commands.
- Save application changes and relevant diagnostic information.
- Shut down the controller according to the machine manufacturer’s instructions.
- Isolate the 24 VDC supply before removing the controller or its connected modules.
- Verify electrical isolation before disconnecting wiring or bus connections.
Normal Operating Procedure
- Monitor controller diagnostics and communication status during machine operation.
- Check Sercos communication for drive-network errors or interrupted cyclic data exchange.
- Monitor local S20 I/O modules for configuration and communication faults.
- Maintain stable 24 VDC power within the specified operating range.
- Keep the controller within its permitted temperature and humidity conditions.
- Use the engineering Ethernet interface for authorized diagnostics and application maintenance.
- Maintain backups of PLC programs, motion configurations, and relevant system parameters.
- Record controller identification, hardware information, and software versions after maintenance.
Parameter Settings and Modification
The XM2200 is configured through the applicable Bosch Rexroth engineering environment. The exact software version and supported firmware combination must be verified before modifying an existing installation.
- Confirm the controller identity and firmware before downloading an application.
- Verify the PLC and Motion Standard function package.
- Configure Sercos communication according to the connected drive architecture.
- Assign S20 I/O modules and verify their addresses and channel mappings.
- Configure optional fieldbus interfaces only when the corresponding extension hardware and software are installed.
- Check network addresses and communication parameters before connecting the controller to an operating machine network.
- Back up the existing application and controller configuration before making changes.
- Document all modifications and complete functional testing before returning the equipment to production.
Maintenance and Troubleshooting
Routine Maintenance
- Inspect the controller housing and connectors for dust, corrosion, or mechanical damage.
- Check the 24 VDC supply terminals for loose connections or signs of overheating.
- Inspect the S20 bus base module and extension-module connections.
- Verify Ethernet and Sercos cable condition and connector retention.
- Maintain adequate cabinet ventilation and operating temperature.
- Check SD card condition and maintain current application backups.
- Review diagnostic records for recurring controller or communication faults.
Common Troubleshooting Checks
- Controller does not start: Check the 24 VDC supply, polarity, terminal connections, and power quality.
- Ethernet communication failure: Verify the network cable, IP configuration, engineering workstation settings, and interface status.
- Sercos communication fault: Inspect both network connections, connected drives, topology, and communication configuration.
- S20 I/O modules not detected: Check the bus base module, module seating, I/O configuration, and controller diagnostics.
- Application download failure: Confirm the controller model, firmware compatibility, engineering software version, and function package.
- Unexpected controller reset: Investigate supply interruptions, cabinet temperature, hardware connections, and diagnostic history.
- Expansion module unavailable: Verify the installed XFE module, bus connection, and supported configuration.
Safety Precautions
- Installation and servicing must be performed by qualified industrial automation personnel.
- Disconnect the 24 VDC supply before removing or installing the controller.
- Observe electrostatic discharge precautions when handling electronic modules.
- Do not connect or disconnect S20 or XM extension modules while energized unless explicitly permitted by the applicable documentation.
- Verify fieldbus wiring and network configuration before connecting the controller to an operating system.
- Do not assume that different XM21 and XM22 variants are interchangeable.
- Back up the original PLC and motion-control application before replacing the controller.
- Complete I/O checks, drive communication tests, and machine safety validation before returning the equipment to service.
Recommended Bosch Rexroth Related Models
The following models are related to the IndraControl XM21/XM22 controller family and its associated automation architecture. They are useful for spare-parts research but are not all direct replacements for R911370638.
- R911370639 – XM2100.01 IndraControl XM21 Controller
- R911370704 – XM2100.01 IndraControl XM21 Controller
- R911375025 – XM2100.01 IndraControl XM21 Controller
- R911391308 – XM2100.01 IndraControl XM21 Controller
- R911391313 – XM2100.01 IndraControl XM21 Controller
- R911388677 – XM2200.01 IndraControl XM22 Controller
- R911391318 – XM2200.01 IndraControl XM22 Controller
- R911391324 – XM2200.01 IndraControl XM22 Controller
- R911173397 – XFE01.1-FB-03 Extension Module
- R911173957 – XFE01.1-FB-20 Extension Module
- R911173120 – S20-AI6-A02-SSI2 Analog Input Module
- R911173461 – S20-PWM-4-T PWM Module
- R911340667 – IndraControl XM21/XM22 Hardware Documentation Reference
- R911342844 – XM21 OCI Function Package
- R911344247 – XM22 Hydraulic Function Package