Product Introduction
The B&R ACOPOSmulti I0055D inverter module, model 8BVI0055HWD0.000-1, is a wall-mounted, two-axis servo inverter designed for high-performance industrial motion control applications. It integrates two independent power inverters in one module, allowing two servo motors to be controlled within a common ACOPOSmulti drive architecture. Each motor connection supports a continuous output current of 7.6 A and continuous motor power of 5.5 kW. The module operates from a nominal 750 V DC intermediate circuit and includes connections for motor holding brakes and temperature sensors, as well as two slots for ACOPOSmulti plug-in modules. Integrated safety-related functions include uncontrolled standstill and safe stop. The 8BVI0055HWD0.000-1 is suitable for machine automation, synchronized motion systems, packaging equipment, and other applications requiring coordinated multi-axis servo control. Proper selection requires verification of the DC bus, motor ratings, feedback configuration, plug-in modules, cooling conditions, and Automation Studio hardware configuration.

Technical Parameters
- Brand: B&R Industrial Automation
- Model: 8BVI0055HWD0.000-1
- Product Designation: ACOPOSmulti I0055D
- Product Name: ACOPOSmulti Two-Axis Inverter Module
- Product Type: Servo Drive / Inverter Module
- Series: B&R ACOPOSmulti
- B&R ID Code: 0x20B5
- Axis Configuration: 2 independent motor axes
- Cooling and Mounting: Wall mounting
- Nominal DC Bus Voltage: 750 V DC
- Continuous Power Consumption: 11.19 kW
- DC Bus Capacitance: 330 µF
- Continuous Motor Power: 5.5 kW per motor connection
- Continuous Output Current: 7.6 A RMS per motor connection
- Peak Output Current: 18.9 A RMS per motor connection
- Nominal Switching Frequency: 5 kHz
- Selectable Switching Frequencies: 5 / 10 / 20 kHz
- Maximum Output Frequency: 598 Hz
- 24 V DC Supply Input: 25 V DC ±1.6%
- 24 V DC Outputs: 2
- Plug-In Module Slots: 2
- Motor Connections: U, V, W, PE
- Motor Holding Brake: Integrated connection and control support
- Motor Temperature Sensor: Integrated connection support
- Protective Functions: Overload, short-circuit, and ground-fault protection
- Safety Functions: Integrated uncontrolled standstill and safe stop; verify the required safety configuration and certification for the application
- Maximum Motor Cable Length: 25 m at 5 kHz and 10 kHz; 10 m at 20 kHz
- Protection Rating: IP20
- Operating Temperature: 5 to 40°C nominal; maximum 55°C subject to derating conditions
- Storage Temperature: -25 to 55°C
- Relative Humidity: 5 to 85% during operation
- Dimensions: Approximately 53 × 317 × 263 mm (W × H × D)
- Weight: Approximately 2.9 kg
- Certifications: CE, UKCA, cULus E225616, and KC
- Place of Manufacture: Austria is listed for this model by a distributor; verify the individual unit’s nameplate
- Country of Origin: Austria, subject to confirmation from the supplied unit
- Product Status: Listed in the B&R product catalog; confirm regional availability and lifecycle status
- Discontinued: Not confirmed as discontinued
- Condition: Depends on the individual seller’s inventory; verify whether supplied as new surplus, unused, or refurbished
Technical Features
- Two Independent Servo Axes: Integrates two fully independent power inverters in one compact module.
- High-Power DC Bus: Uses a nominal 750 V DC intermediate circuit for ACOPOSmulti drive operation.
- 5.5 kW Per Axis: Supports continuous motor power of up to 5.5 kW per motor connection under specified operating conditions.
- 7.6 A Continuous Current: Provides 7.6 A RMS continuous current per motor connection, with peak current capability of 18.9 A RMS.
- Flexible Switching Frequency: Supports 5, 10, and 20 kHz switching frequencies, with current and motor cable limits depending on the selected frequency.
- Plug-In Expansion: Includes two slots for compatible ACOPOSmulti plug-in modules.
- Motor Brake Support: Provides connections for motor holding brakes, with internal or external activation options according to the application configuration.
- Temperature Monitoring: Supports motor temperature sensor connections.
- Integrated Safety Functions: Includes uncontrolled standstill and safe-stop functionality. The complete safety design must follow B&R documentation.
- Protective Monitoring: Includes overload, short-circuit, and ground-fault protection.
- Wall-Mounted Design: Suitable for installation in an appropriately designed industrial electrical cabinet.
Typical Application Areas
- Industrial machine automation
- Packaging and filling machinery
- Printing and converting equipment
- Material handling and conveyor systems
- Synchronized multi-axis machinery
- Robotics and automated production equipment
- CNC and precision motion applications
- High-speed production lines
- Assembly and handling systems
The final application depends on motor compatibility, feedback devices, drive configuration, mechanical load, and the capabilities of the ACOPOSmulti system controller.
Operating Procedures
1. Pre-Installation Inspection
- Verify the complete model number: 8BVI0055HWD0.000-1.
- Inspect the housing, connectors, DC bus terminals, and motor terminals.
- Check for cracks, corrosion, contamination, or signs of overheating.
- Confirm that the two motor axes match the intended machine configuration.
- Verify the DC bus voltage and motor ratings.
- Check the required plug-in modules, terminal blocks, and accessory kits.
- Confirm that the module revision is supported by the installed Automation Studio hardware configuration.
2. Installation
- Isolate the DC bus and auxiliary power supplies before installation.
- Observe the required DC bus discharge time and verify that the DC bus voltage has fallen to a safe level.
- Install the module in the specified vertical wall-mounting orientation or another manufacturer-approved orientation.
- Provide sufficient cabinet ventilation and clearance.
- Connect the DC bus according to the approved ACOPOSmulti system design.
- Connect the motor phases U, V, and W, together with protective earth.
- Connect motor feedback, temperature sensors, and holding-brake wiring as required.
- Install compatible plug-in modules and terminal blocks.
- Connect the 24 V DC supply according to the wiring documentation.
- Check cable shielding and grounding before commissioning.
3. Startup and Power-On
- Verify that all power and motor connections are correctly installed.
- Confirm the DC bus voltage and auxiliary 24 V DC supply.
- Check the motor and feedback configuration in Automation Studio.
- Confirm that the selected motor data matches the actual motor nameplate.
- Verify the drive’s safety configuration and stop functions.
- Restore power according to the approved machine startup sequence.
- Check the drive status and diagnostic messages.
- Perform low-speed functional tests on each axis before enabling normal production operation.
4. Normal Operation
- Monitor motor current, drive temperature, and DC bus conditions.
- Check the status of both axes independently.
- Observe acceleration, deceleration, and braking behavior.
- Monitor motor feedback and temperature signals.
- Check for abnormal vibration, noise, or unexpected torque behavior.
- Review drive diagnostics if an axis stops or reports a fault.
- Keep motor cable lengths and switching frequency within the manufacturer’s specified limits.
5. Parameter Configuration and Modification
- Use the appropriate B&R Automation Studio version and hardware configuration.
- Select the correct 8BVI0055HWD0.000-1 device definition.
- Configure the motor type, rated current, rated voltage, feedback device, and other required motor parameters.
- Set acceleration, deceleration, velocity, and torque limits according to the machine design.
- Configure the motor holding-brake control and monitoring where applicable.
- Configure the required safety functions according to the approved safety design.
- Save and back up the original project before modifying parameters.
- Validate both axes independently after configuration changes.
6. Shutdown and Removal
- Stop the machine using the approved shutdown sequence.
- Disable the inverter and isolate the DC bus supply.
- Wait for the specified discharge period.
- Verify the DC bus voltage with an appropriate measuring instrument before touching power terminals.
- Disconnect motor and auxiliary wiring only after confirming a safe electrical condition.
- Remove the module carefully from its mounting arrangement.
- Protect the inverter against electrostatic discharge and mechanical damage during storage.
Daily Maintenance
- Check drive diagnostics and operating status.
- Inspect cabinet ventilation and cooling paths.
- Check for dust accumulation and abnormal temperature.
- Inspect motor and DC bus connections during scheduled maintenance.
- Check protective earth and cable shielding.
- Monitor motor current and drive loading.
- Review fault history and repeated alarm patterns.
- Verify that motor cables and switching frequency remain within the specified limits.
- Keep the Automation Studio project and drive parameter backups up to date.
Troubleshooting
1. Inverter Module Does Not Start
- Check the 24 V DC auxiliary supply.
- Verify the DC bus voltage.
- Inspect the module’s power and control connections.
- Review the drive diagnostic messages.
- Confirm that the hardware configuration matches the installed module.
2. Motor Overcurrent or Overload Fault
- Verify motor nameplate data and configured motor parameters.
- Check mechanical load and motor condition.
- Inspect motor cables for short circuits or insulation damage.
- Confirm that acceleration and deceleration settings are appropriate.
- Check the switching frequency and applicable current derating.
3. Motor Feedback Error
- Inspect the feedback cable and connectors.
- Confirm the selected feedback device type.
- Check cable shielding and grounding.
- Verify the feedback configuration in Automation Studio.
4. Motor Overtemperature
- Check the motor temperature sensor connection.
- Inspect motor cooling and ventilation.
- Verify that the motor is operating within its rated load.
- Check the drive’s temperature monitoring configuration.
5. DC Bus Fault
- Measure the DC bus voltage using approved procedures.
- Check the DC bus supply and connections.
- Inspect for abnormal voltage fluctuations.
- Review regenerative energy and braking conditions.
- Follow the ACOPOSmulti troubleshooting instructions.
6. One Axis Operates Incorrectly
- Check the individual motor connection and feedback wiring.
- Review the affected axis parameters.
- Verify the motor brake and temperature sensor connections.
- Compare the configuration of both axes without assuming identical motor requirements.
Frequently Asked Questions
Q1: What is the B&R 8BVI0055HWD0.000-1?
It is a two-axis ACOPOSmulti inverter module designed to control two independent servo motors.
Q2: What is the rated power per axis?
The module supports continuous motor power of 5.5 kW per motor connection under the specified operating conditions.
Q3: What is the continuous output current?
The rated continuous output current is 7.6 A RMS per motor connection. The specified peak current is 18.9 A RMS.
Q4: What DC bus voltage does it use?
The nominal DC bus voltage is 750 V DC.
Q5: How many motor axes does it support?
It supports two independent motor connections in one inverter module.
Q6: Which software is used for configuration?
B&R Automation Studio is used for system engineering and hardware configuration. The installed software version must support the module’s hardware revision.
Q7: Does the module include safety functions?
Yes. The module includes integrated uncontrolled standstill and safe-stop functionality. The required safety performance depends on the complete system design, configuration, and validation.
Q8: What should be checked before purchasing a replacement?
Verify the complete part number, hardware revision, motor ratings, DC bus compatibility, plug-in modules, terminal block arrangement, and software support.
Safety Precautions
- ⚠️ Only qualified personnel should install, commission, or maintain this inverter module.
- ⚠️ The DC bus can retain dangerous voltage after the power supply is switched off. Follow the specified discharge procedure and verify the voltage before handling.
- ⚠️ Never connect or disconnect motor cables while the inverter is energized.
- ⚠️ Confirm the DC bus voltage and motor ratings before commissioning.
- ⚠️ Provide proper protective earth and cable shielding.
- ⚠️ Maintain the specified installation orientation, ventilation, and environmental conditions.
- ⚠️ Do not bypass integrated safety functions or external safety circuits.
- ⚠️ Validate the complete machine safety system before returning the equipment to production.
15 Related B&R ACOPOSmulti Models
The following models belong to the B&R ACOPOSmulti inverter and drive product family. They may be relevant for system expansion or spare-parts sourcing, but they are not automatic drop-in replacements for 8BVI0055HWD0.000-1.
- 8BVI0028HWD0.000-1 – ACOPOSmulti two-axis inverter module.
- 8BVI0030HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0045HWD0.000-1 – ACOPOSmulti two-axis inverter module.
- 8BVI0072HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0100HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0135HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0160HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0220HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0300HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0370HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0450HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0550HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI0750HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI1100HWD0.000-1 – ACOPOSmulti inverter module.
- 8BVI1500HWD0.000-1 – ACOPOSmulti inverter module.
Always verify the complete order number, current rating, axis configuration, mounting style, DC bus requirements, and system compatibility before selecting a replacement.