Product Description
The B&R ACOPOSmulti 8BVP0880HW00.008-1 is an 88 A power supply module designed for industrial servo drive systems and high-performance motion control applications. This wall-mounted ACOPOSmulti module converts three-phase AC input power into a regulated DC bus supply and supports both energy supply and regenerative operation. It provides a nominal DC bus voltage of 750 VDC, continuous power of 60 kW, and peak power of 120 kW, making it suitable for multi-axis machinery, packaging equipment, printing systems, automated production lines, and material handling applications. The module supports 3-phase 220–480 VAC input, includes power factor correction and overload protection, and provides two slots for plug-in modules. Its integration into an ACOPOSmulti system requires compatible drive modules, correct DC bus configuration, appropriate protective devices, and proper electrical grounding. The listed item is described as C0 Mint Condition; buyers should verify the actual physical condition, accessories, and nameplate before installation.
Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | B&R Industrial Automation |
| Model | 8BVP0880HW00.008-1 |
| Series | ACOPOSmulti |
| Product Name | 88 A Power Supply Module |
| Product Type | Regenerative Servo Drive Power Supply |
| Place of Manufacture | Not independently verified |
| Product Status | C0 Mint Condition (seller-listed condition) |
| Dimensions | 317 × 213.5 × 263 mm (H × W × D) |
| Weight | Approx. 11.10 kg |
| Country of Origin | Not independently verified |
| Input Voltage | 3 × 220–480 VAC ±10% |
| Input Frequency | 50 / 60 Hz ±4% |
| DC Bus Voltage | 750 VDC nominal |
| Continuous Power | 60 kW |
| Peak Power | 120 kW |
| Rated Current | 88 A |
| Protection Rating | IP20 |
| Mounting | Wall mounting |
| Discontinued | Not confirmed; check current manufacturer availability |
⚙️ Operating Procedures and Usage Instructions
1. Installation and Preparation
- Verify the complete model number and nameplate specifications.
- Inspect the housing, terminals, DC bus connections, and cooling fan.
- Install the module vertically or horizontally with its front face upward, as permitted by the manufacturer.
- Maintain the required cabinet clearance and ventilation.
- Connect the protective earth (PE) and three-phase input terminals L1, L2, and L3.
- Connect the DC bus to compatible ACOPOSmulti drive modules.
- Install the required terminal block accessories and protective devices.
- Check cable sizing, grounding, phase sequence, and electrical protection before energizing.
2. Power-On Sequence
- Confirm that all electrical connections are secure.
- Verify that the motor drives and connected equipment are correctly installed.
- Check the incoming three-phase supply voltage.
- Switch on the main electrical supply according to the machine’s approved power-up procedure.
- Allow the power supply module to initialize.
- Check the DC bus voltage and system status through the appropriate diagnostics.
- Verify communication with the controller and connected drive modules.
- Enable the motion system only after all safety interlocks and drive-ready signals are confirmed.
Important: Observe the manufacturer’s specified switch-on interval of more than 300 seconds. Do not repeatedly cycle the mains supply.
3. Normal Operating Procedure
- Start the machine controller and initialize the ACOPOSmulti system.
- Confirm that the power supply module reports normal operating status.
- Check the DC bus voltage and drive-module communication.
- Verify that connected servo axes are ready.
- Release the machine’s safety interlocks according to the approved procedure.
- Enable the servo drives.
- Execute a low-speed test movement.
- Gradually increase the production speed and load within the rated system limits.
- Monitor DC bus voltage, current, temperature, and fault messages during operation.
4. Parameter Configuration and Modification
- Connect a compatible engineering workstation running B&R Automation Studio.
- Establish communication with the machine controller and ACOPOSmulti system.
- Read and back up the existing project and hardware configuration.
- Verify the installed power supply module identification.
- Check the DC bus configuration and connected drive-module settings.
- Confirm switching frequency and operating limits against the module specifications.
- Review regenerative energy handling and the connected system’s power requirements.
- Save approved configuration changes and perform commissioning tests.
- Record the final parameter set for future maintenance.
Do not change voltage limits, protection settings, or drive parameters beyond manufacturer-approved values.
5. Shutdown Sequence
- Stop the machine’s automatic production cycle.
- Command all servo axes to decelerate to zero speed.
- Confirm that all connected motors have stopped.
- Disable the servo drives through the controller.
- Follow the machine’s approved DC bus discharge and shutdown procedure.
- Isolate the incoming three-phase power supply.
- Apply lockout/tagout procedures before maintenance.
- Verify that the DC bus voltage has fallen to a safe level before touching electrical terminals.
🔧 Daily Maintenance and Troubleshooting
- Inspect electrical connections for looseness, discoloration, or overheating.
- Check cooling fans and ventilation passages for dust accumulation.
- Monitor abnormal temperature increases and unusual operating noise.
- Inspect DC bus connections and protective earth wiring.
- Check controller diagnostics for overload, undervoltage, or communication faults.
- Investigate regenerative energy and DC bus alarms before restarting.
- Record operating conditions and recurring faults for preventive maintenance.
⚠️ Safety Precautions
- Installation and servicing must be performed by qualified industrial electrical personnel.
- The module operates with hazardous three-phase AC and high-voltage DC.
- Never disconnect power or DC bus connections while energized.
- Observe the specified DC bus discharge time and verify voltage independently.
- Do not assume that overload protection also provides short-circuit or ground-fault protection.
- Use correctly rated fuses or circuit breakers.
- Maintain the specified installation orientation and environmental conditions.
- Follow the official B&R ACOPOSmulti installation and operating documentation.
🔗 Product Information
B&R ACOPOSmulti 8BVP0880HW00.008-1 – 88 A Power Supply Module.
For industrial automation spare parts and ACOPOSmulti products, visit B&R ACOPOSmulti and industrial automation spare parts.
Recommended B&R Models
- B&R 8BVP0220HW00.000-1 – 22 A Power Supply Module
- B&R 8BVP0440HW00.000-1 – 44 A Power Supply Module
- B&R 8BVP0880HW00.004-1 – 88 A Power Supply Module
- B&R 8BVP0880HW00.008-3 – ACOPOSmulti3 88 A Power Supply
- B&R 8BVP1650HW00.000-1 – 165 A Power Supply Module
- B&R 8BVP1650HW00.004-1 – 165 A Power Supply Module
- B&R 8BVP0220HW00.000-3 – ACOPOSmulti3 22 A Power Supply
- B&R 8BVP0440HW00.000-3 – ACOPOSmulti3 44 A Power Supply
- B&R 8BVP1650HW00.004-3 – ACOPOSmulti3 165 A Power Supply
- B&R 8BVI0014HWD0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVI0028HWD0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVI0055HWD0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVI0110HWD0.000-1 – ACOPOSmulti Inverter Module
- B&R 8B0C0320HW00.000-1 – ACOPOSmulti System Component
- B&R 8BXF001.0000-00 – ACOPOSmulti Replacement Fan Module