Product Description
The B&R 8BVP0880HW00.008-1 is an 88 A ACOPOSmulti power supply module designed for industrial servo drive systems and high-performance motion control applications. It converts three-phase AC input power into a regulated 750 VDC intermediate DC bus and supports both power supply and regenerative energy feedback. With a continuous power rating of 60 kW and peak power capability of 120 kW, this module provides centralized power management for multiple servo axes in automated production equipment. It features wall mounting, power factor correction (PFC), overload protection, and compatibility with the ACOPOSmulti backplane architecture. Typical applications include packaging machinery, printing equipment, material handling systems, automated assembly lines, and multi-axis industrial motion control installations. The C0 Mint Condition designation refers to the seller’s stated item condition and should be confirmed through physical inspection.

Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | B&R (Bernecker + Rainer) |
| Model | 8BVP0880HW00.008-1 |
| Series | ACOPOSmulti |
| Product Name | 88 A Power Supply Module |
| Place of Manufacture | Not independently verified |
| Product Status | C0 Mint Condition (seller stated) |
| Dimensions | 317 × 213.5 × 263 mm (H × W × D) |
| Weight | Approx. 11.10 kg |
| Country of Origin | Not independently verified |
| Power Requirements | 3 × 220–480 VAC ±10%, 50/60 Hz ±4% |
| DC Bus Voltage | 750 VDC nominal |
| Continuous Power | 60 kW |
| Peak Power | 120 kW |
| Rated Current | 88 A |
| Switching Frequency | 5 kHz nominal; 5/10 kHz selectable |
| Protection Rating | IP20 |
| Cooling / Installation | Wall mounting |
| Regenerative Capability | Yes |
| Power Factor Correction | Yes |
| Discontinued | Current production status not confirmed |
⚙️ Operating Procedures and Usage Instructions
1. Installation and Preparation
- Verify the complete model number and inspect the housing, terminals, and mounting points.
- Install the module vertically or horizontally with its face upward, following the manufacturer’s mounting requirements.
- Maintain adequate clearance for cooling and ventilation.
- Verify the three-phase input voltage, grounding arrangement, and upstream circuit protection.
- Connect the AC input terminals L1, L2, L3, and PE using the specified M8 connections.
- Check the DC bus connections and compatibility with the ACOPOSmulti backplane.
- Confirm that all required terminal block sets and accessories are installed.
2. Power-On Sequence
- Confirm that all servo drives and connected equipment are correctly installed.
- Verify the incoming three-phase power supply.
- Check protective earth and electrical connections.
- Confirm that the DC bus capacitance is within the permitted charging limits.
- Energize the main AC supply according to the manufacturer’s commissioning procedure.
- Allow the power supply module to complete its startup and DC bus charging process.
- Check the DC bus voltage and module status.
- Enable the connected servo drives only after the power system is ready.
- Perform a controlled low-load test before normal operation.
Important: Observe the manufacturer’s specified switch-on interval of more than 300 seconds where applicable. Follow the approved precharge and restart procedures.
3. Normal Operating Procedure
- Confirm that the power supply module reports normal operating status.
- Check that the DC bus voltage is approximately 750 VDC under nominal conditions.
- Verify communication and status information through the connected ACOPOSmulti system.
- Enable the connected servo drive axes.
- Start the machine at reduced speed and load.
- Monitor power consumption, DC bus voltage, and module temperature.
- Check regenerative operation during controlled deceleration.
- Increase the machine load within the permitted operating limits.
- Record alarms and operating abnormalities for maintenance purposes.
4. Parameter Configuration and Modification
- Use compatible B&R Automation Studio engineering software.
- Verify the hardware configuration and ACOPOSmulti system architecture.
- Check the module identification and hardware revision.
- Configure permitted switching frequency options (5 kHz or 10 kHz) according to the system design.
- Verify DC bus operating limits and connected drive requirements.
- Check power derating according to input voltage, temperature, and installation altitude.
- Review overload and regenerative operating conditions.
- Back up the existing project before modifying system parameters.
- Restart and test the system according to the approved commissioning procedure.
Do not change hardware protection limits or electrical ratings beyond the manufacturer’s specifications.
5. Shutdown Sequence
- Stop the machine’s automatic production cycle.
- Command all connected servo axes to decelerate to zero speed.
- Allow regenerative energy feedback and DC bus conditions to stabilize.
- Disable the servo drives.
- Switch off the main AC supply following the system shutdown procedure.
- Wait for the DC bus capacitors to discharge.
- Verify the absence of hazardous voltage before maintenance.
- Apply lockout/tagout procedures before opening electrical connections.
🔧 Daily Maintenance and Troubleshooting
- Inspect power terminals and cable connections for overheating or discoloration.
- Check cooling fans and ventilation passages for dust accumulation.
- Monitor DC bus voltage and operating temperature.
- Inspect grounding and shielding connections.
- Check for overload, undervoltage, and regenerative operation alarms.
- Verify that connected servo modules remain within their rated power limits.
- Replace damaged cooling fans or terminal accessories with approved components.
Common Troubleshooting
DC Bus Undervoltage: Check incoming AC voltage, phase connections, and supply loading.
Overtemperature Alarm: Inspect cooling fans, ventilation clearance, ambient temperature, and installation conditions.
Overload Alarm: Check connected servo axis power demand and regenerative operating conditions.
Power Supply Startup Failure: Verify the input supply, protective devices, wiring, and module status.
Abnormal Regenerative Operation: Check the connected servo drives, DC bus configuration, and energy feedback conditions.
⚠️ Safety Precautions
- Installation and maintenance must be performed by qualified industrial electrical personnel.
- The module operates with hazardous AC and DC voltages.
- Never disconnect power terminals while energized.
- Always verify DC bus discharge before servicing.
- Do not exceed the specified input voltage or DC bus operating limits.
- Provide appropriate external short-circuit and ground-fault protection.
- Observe the specified installation orientation and environmental conditions.
- Use the manufacturer’s wiring diagrams and commissioning documentation.
🔗 Product Keywords and Information
B&R ACOPOSmulti 8BVP0880HW00.008-1, 88 A Power Supply Module, 750 VDC, 60 kW, 120 kW Peak Power, Regenerative Servo Power Supply.
Industrial automation spare parts and B&R motion control products:
Recommended B&R Models
- B&R 8BVP0220HW00.000-1 – ACOPOSmulti 22 A Power Supply Module
- B&R 8BVP0440HW00.000-1 – ACOPOSmulti 44 A Power Supply Module
- B&R 8BVP0880HW00.004-1 – ACOPOSmulti 88 A Power Supply Module
- B&R 8BVP0880HW00.008-3 – ACOPOSmulti3 88 A Power Supply Module
- B&R 8BVP1650HW00.000-1 – ACOPOSmulti 165 A Power Supply Module
- B&R 8BVP1650HW00.004-1 – ACOPOSmulti 165 A Power Supply Module
- B&R 8BVP0220HW00.000-3 – ACOPOSmulti3 22 A Power Supply Module
- B&R 8BVP0440HW00.000-3 – ACOPOSmulti3 44 A Power Supply Module
- B&R 8B0C0320HW00.000-1 – ACOPOSmulti Capacitor Module
- B&R 8B0C0500HW00.000-1 – ACOPOSmulti Capacitor Module
- B&R 8BVI0055HWD0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVI0220HWD0.000-1 – ACOPOSmulti Inverter Module
- B&R 8BVE0220HCS0.000-1 – ACOPOSmulti Inverter Module
- B&R 8B0K0015HW00.000-1 – ACOPOSmulti Brake Chopper Module
- B&R 8B0K0028HW00.000-1 – ACOPOSmulti Brake Chopper Module