The Rexroth R914511507 COREX-M-X7-31-BNNN-21.01-02RS-NN-NN is an industrial control platform from the Bosch Rexroth ctrlX CORE family, designed for advanced automation, PLC applications, machine control, and industrial networking. Featuring an Intel Core i7-1185 processor, 16 GB RAM, and 32 GB eMMC storage, this controller provides computing capacity for demanding automation applications and software-based control tasks. The ctrlX platform uses a Linux-based operating system and supports the integration of ctrlX WORKS engineering applications, automation software, and third-party applications. Its Ethernet interfaces, USB connectivity, and modular expansion options support communication between machine-level equipment, control systems, and higher-level industrial IT networks. Typical applications include production machinery, packaging systems, automated assembly, material handling, and smart manufacturing installations. Before replacement or commissioning, verify the hardware configuration, firmware, software licenses, communication interfaces, and expansion modules against the existing machine configuration.

📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | Bosch Rexroth |
| Model | R914511507 |
| Full Model | COREX-M-X7-31-BNNN-21.01-02RS-NN-NN |
| Series | ctrlX COREplus X7 |
| Product Name | Industrial Controller / Control Platform |
| Processor | Intel Core i7-1185 |
| Memory | 16 GB RAM |
| Internal Storage | 32 GB eMMC |
| Operating System | Linux-based ctrlX OS platform |
| Power Requirements | 24 V DC nominal |
| Permitted Supply Voltage | 19.2–30 V DC |
| Communication Interfaces | 5 × Ethernet RJ45, 1 × DisplayPort, 3 × USB Type-C, SD card slot |
| Dimensions | Refer to the manufacturer’s COREplus X7 mechanical drawing |
| Weight | Approximately 1.2 kg without expansion modules |
| Country of Origin | Not independently verified |
| Product Status | Confirm actual condition against seller listing |
| Discontinued | Current production status requires manufacturer confirmation |
⚙️ Operating Procedures and Usage Instructions
1. Installation and Preparation
- Inspect the controller housing, connectors, mounting points, and expansion interfaces.
- Verify the R914511507 part number and hardware configuration.
- Install the controller in a suitable industrial control cabinet.
- Ensure sufficient clearance and ventilation for heat dissipation.
- Connect the 24 V DC supply using the specified terminals and approved wiring.
- Connect the engineering Ethernet interface to the commissioning computer.
- Connect field networks and peripheral devices according to the approved system architecture.
2. Power-On Sequence
- Confirm that all wiring and protective grounding connections are correct.
- Check that the DC power supply provides a stable 24 V DC output.
- Ensure that connected field devices are in a safe operating condition.
- Switch on the controller’s 24 V DC supply.
- Allow the ctrlX CORE system to complete its startup process.
- Check the controller’s status indicators and Ethernet connections.
- Establish communication with the engineering workstation.
- Verify the operating system, installed applications, and controller configuration.
- Enable machine operation only after all communication and safety checks are complete.
3. Normal Operating Procedure
- Open the compatible ctrlX engineering environment.
- Establish an Ethernet connection with the controller.
- Confirm the controller identity and hardware configuration.
- Check installed PLC and automation applications.
- Verify EtherCAT or other configured industrial communication networks.
- Confirm I/O mapping and field-device communication.
- Load the approved control project.
- Check diagnostic messages and system status.
- Place the machine into the approved operating mode.
- Monitor controller temperature, communication status, and application diagnostics during operation.
4. Parameter Configuration and Modification
- Connect to the controller through its engineering Ethernet interface.
- Access the appropriate ctrlX management and engineering environment.
- Back up the existing project, application settings, and network configuration.
- Verify the installed ctrlX OS version and application compatibility.
- Configure Ethernet addresses and communication interfaces according to the network plan.
- Configure PLC applications, I/O assignments, and fieldbus parameters.
- Install or update software applications only after checking version compatibility and licensing.
- Save the configuration and restart the relevant applications when required.
- Test all communication connections before returning the machine to production.
5. Shutdown Sequence
- Stop the machine through its normal control procedure.
- Bring all controlled axes and processes to a safe state.
- Stop active PLC applications and software services according to the machine procedure.
- Save configuration changes and verify that required data has been backed up.
- Shut down the controller using the approved system procedure.
- Switch off the 24 V DC supply after the shutdown process is complete.
- Disconnect cables only after electrical isolation has been verified.
🔧 Daily Maintenance and Troubleshooting
- Inspect Ethernet, USB, and power connections for looseness or damage.
- Check controller status indicators and system diagnostic messages.
- Monitor CPU temperature and cabinet ventilation.
- Verify available storage capacity and system resource usage.
- Back up PLC projects, application configurations, and licenses.
- Investigate communication interruptions by checking network cables, IP addresses, and device configurations.
- For startup failures, check the 24 V DC supply and system boot diagnostics.
- For application errors, verify software versions, dependencies, and licensing.
- Replace or service expansion modules only after checking hardware compatibility.
⚠️ Safety Precautions
- Installation and maintenance must be performed by qualified automation personnel.
- Use a regulated 24 V DC SELV/PELV supply within the specified voltage range.
- Isolate the power supply before installing or removing hardware.
- Do not disconnect storage devices or interrupt power during critical write operations.
- Maintain appropriate cabinet ventilation and environmental conditions.
- Back up the original configuration before changing firmware or software.
- Do not assume that different ctrlX CORE models have identical hardware, interfaces, or software capabilities.
- Safety-related machine functions must use appropriately rated safety components and validated safety architectures.
🔗 Product Keywords and Information
Bosch Rexroth R914511507, COREX-M-X7, ctrlX COREplus X7, Industrial PLC Controller, Industrial Automation Controller, Machine Control System, ctrlX OS, Industrial Ethernet, EtherCAT Controller.
For industrial automation controllers and replacement parts, visit:
Recommended Bosch Rexroth Models
- R914511508 – ctrlX COREplus X3 Controller
- R914511507 – ctrlX COREplus X7 Controller
- R914518351 – ctrlX COREplus X7 Controller Variant
- R911419121 – ctrlX COREplus X5 Controller
- R911419122 – ctrlX COREplus X7 Controller
- R911170901 – IndraControl XM Controller
- R911170902 – IndraControl XM Controller
- R911173720 – IndraControl L45 Controller
- R911173721 – IndraControl L65 Controller
- R911325368 – IndraControl VPB40.3
- R911172553 – IndraControl CML Controller
- R911305278 – IndraControl VEP Operator Panel
- R911312388 – IndraControl VEP40.4
- R911322059 – IndraControl VEP50.4
- R911317018 – IndraControl VPB40.3 Industrial PC
Note: Recommended models belong to the broader Bosch Rexroth automation portfolio. They are not all direct plug-and-play replacements. Verify hardware, firmware, interfaces, and application compatibility before substitution.