Product Description
The B&R 8EI4X5MWD10.0600-1 is a two-axis ACOPOS P3 servo drive designed for precise motor control in industrial automation, packaging machinery, machine tools, and multi-axis motion systems. This wall-mounted servo amplifier provides two motor connections, each rated for 4.5 A continuous output current, with a digital multi-standard encoder interface for each axis. It supports three-phase 200–230 V AC mains input and includes an integrated braking resistor, a DC bus connection, and a plug-in module slot for additional functionality. The drive communicates with a compatible B&R automation controller through the ACOPOS P3 system architecture and requires suitable motor, feedback, power, and software configuration. This listing describes the unit as New Original Packaging; buyers should confirm the included connector set, cover, firmware or configuration requirements, and packaging condition before installation.

Key Product Parameters
- Brand: B&R Industrial Automation
- Model: 8EI4X5MWD10.0600-1
- Product Series: ACOPOS P3
- Product Type: Two-Axis AC Servo Amplifier
- Mounting Type: Wall mounting
- Number of Axes: 2
- Continuous Output Current: 4.5 A per axis
- Peak Output Current: 12.25 A per axis
- Continuous Motor Power: 1 kW per axis
- Peak Output Power: 2.5 kW total
- Mains Input: 3 × 200–230 V AC ±10%
- Additional Mains Input Range: 1 × 110–230 V AC ±10%
- Mains Frequency: 50/60 Hz ±4%
- Maximum Installed Load: 5 kVA
- DC Bus Continuous Power: 2 kW
- DC Bus Capacitance: 1,880 µF
- Encoder Interface: 1 digital multi-standard encoder interface per axis
- Integrated Braking Resistor: Yes
- Plug-In Module Slots: 1
- 24 V DC Control Supply: Verify the applicable connection and electrical requirements in the installation manual
- Protection Rating: IP20
- Operating Temperature: 5 to 40°C nominal; maximum 55°C
- Relative Humidity: 5–85%, non-condensing
- Dimensions: 374 × 66 × 258.5 mm (H × W × D)
- Weight: Approximately 4 kg
- Product Status: New Original Packaging, as stated in the seller’s listing
- Country of Origin: Verify from the product nameplate
- Discontinued: Check current B&R availability and support status
Operating Procedures and Usage Instructions
1. Installation Preparation
- Confirm the complete order number 8EI4X5MWD10.0600-1.
- Verify that the drive is the two-axis D-series configuration and not a similar-looking single-axis or three-axis ACOPOS P3 model.
- Check compatibility with the installed B&R controller, motor models, encoder types, and ACP10 software version.
- Confirm the availability of the required connector set, cover, line filter, and motor cables.
- Review the cabinet layout, mounting orientation, grounding arrangement, and cooling requirements.
2. Mechanical Installation
- Install the servo drive vertically in the control cabinet according to B&R mounting instructions.
- Secure the unit using the specified mounting points.
- Maintain the required clearance around the drive for heat dissipation.
- Keep the cabinet free from conductive dust, moisture, and excessive vibration.
- Confirm that the installation environment meets the specified temperature and humidity limits.
3. Electrical Wiring
- Isolate the mains supply and follow lockout/tagout procedures before wiring.
- Install the specified B&R line filter upstream of the drive. Do not select a substitute filter without confirming manufacturer approval.
- Connect the three-phase mains supply according to the applicable wiring diagram and voltage configuration.
- Connect protective earth and verify grounding continuity.
- Connect each motor to its designated axis output.
- Connect the corresponding encoder or feedback cable to the correct interface.
- Wire motor holding brakes and temperature sensors according to the motor and drive documentation.
- Connect the DC bus only when required by the system design and observe the specified polarity and wiring limits.
- Check cable shielding, conductor sizes, terminal torque, and separation between motor and signal wiring.
4. Startup and Commissioning
- Inspect all power, motor, feedback, and communication connections before energizing the system.
- Verify the line-filter arrangement and supply voltage.
- Apply power according to the approved B&R startup sequence.
- Establish communication with the B&R automation controller.
- Confirm that both drive axes are detected and correctly assigned.
- Configure the motor type, encoder feedback, current limits, holding-brake settings, and temperature monitoring.
- Check the drive diagnostics and communication status.
- Test each axis independently at reduced speed and load before enabling normal machine operation.
5. Normal Operation
- Monitor motor current, temperature, drive status, and controller diagnostics during operation.
- Check both axes for abnormal noise, vibration, or unexpected movement.
- Verify that encoder feedback and motor commands remain consistent.
- Monitor braking behavior during deceleration and stopping.
- Keep the control cabinet ventilation paths clear.
6. Parameter Configuration
- Use the B&R ACP10 software environment supported by the installed drive configuration.
- The manufacturer lists ACP10 V3.12.1 support for this model family; verify the required version and project configuration for the actual system.
- Configure axis assignments, motor data, encoder settings, current limits, and braking parameters according to the connected equipment.
- Back up the existing drive and controller parameters before making changes.
- Do not transfer parameter sets between different motor or encoder configurations without engineering verification.
7. Shutdown
- Stop both motor axes using the approved machine-control sequence.
- Disable drive enable signals and isolate the mains supply.
- Allow the DC bus to discharge and verify safe voltage before servicing.
- Disconnect motor and feedback cables only after the system is confirmed de-energized.
- Record cable positions and parameter settings before removing the drive.
Daily Maintenance
- Check drive status indicators and controller diagnostics for warnings or faults.
- Inspect cabinet ventilation and remove accumulated dust from air passages.
- Check the line-filter connections, protective earth, and power terminals during scheduled inspections.
- Inspect motor and encoder cables for abrasion, loose connectors, or shielding damage.
- Monitor motor and drive temperatures under normal operating load.
- Check the integrated braking resistor and braking performance for abnormal heating or fault indications.
- Back up drive parameters and maintain a record of firmware and software versions.
- Keep the unit dry and free from oil mist and conductive contamination.
Troubleshooting
- Drive does not power up: Check mains voltage, line-filter wiring, protective devices, grounding, and supply connections.
- Axis is not detected: Verify the controller configuration, axis assignment, plug-in modules, and communication status.
- Encoder fault: Inspect the feedback cable, connector, encoder type, shielding, and motor configuration.
- Motor does not rotate: Check enable conditions, safety interlocks, motor wiring, feedback status, and drive parameters.
- Overcurrent fault: Check motor cable insulation, phase connections, mechanical load, and current-limit settings.
- Overtemperature warning: Inspect cabinet airflow, ambient temperature, drive loading, and motor cooling.
- Braking fault: Check deceleration settings, braking resistor condition, wiring, and regenerative energy requirements.
- Intermittent communication: Inspect controller connections, network wiring, grounding, and configuration settings.
- Repeated drive faults: Record the complete diagnostic code and operating conditions before resetting or replacing components.
Safety Precautions
- Installation and commissioning must be performed by qualified industrial electrical and automation personnel.
- Disconnect and lock out the mains supply before servicing.
- The DC bus may retain hazardous voltage after power is removed. Verify discharge before touching electrical connections.
- Use the specified line filter and follow B&R installation instructions.
- Never connect or disconnect motor or encoder cables while the drive is energized.
- Ensure protective earth and cable shielding are correctly installed.
- Do not exceed the rated current, voltage, temperature, or braking limits.
- Confirm motor, encoder, firmware, and controller compatibility before enabling the axes.
- Do not bypass safety interlocks or machine emergency-stop circuits.
Product Keywords
B&R 8EI4X5MWD10.0600-1, ACOPOS P3 servo amplifier, B&R two-axis servo drive, 4.5 A servo drive, 2-axis AC servo controller, B&R motion control, integrated braking resistor, digital encoder interface, industrial servo amplifier, B&R automation spare parts, 200–230 V AC servo drive, machine tool motion control, industrial automation drive.
For B&R ACOPOS P3 servo drives, motion-control modules, and industrial automation spare parts, visit https://www.newplcdcs.com.
15 Related Models / Product References
The following are related B&R ACOPOS P3 product references for identification and sourcing research. They are not confirmed direct replacements for 8EI4X5MWD10.0600-1. Verify the number of axes, current rating, encoder interface, voltage range, braking configuration, and connector arrangement before ordering.
- 8EI2X2MWD10.0600-1 – ACOPOS P3 two-axis drive, lower current class.
- 8EI8X8MWD10.0600-1 – ACOPOS P3 two-axis drive, higher current class.
- 8EI4X5MWT10.0600-1 – ACOPOS P3 three-axis drive configuration.
- 8EI4X5MWS10.0600-1 – ACOPOS P3 single-axis drive configuration.
- 8EI4X5MWD10.XXXX-1 – Two-axis product family reference; confirm exact option code.
- 8EI2X2MWD10.XXXX-1 – Two-axis product family reference.
- 8EI8X8MWD10.XXXX-1 – Two-axis product family reference.
- 8EI4X5MWT10.XXXX-1 – Three-axis product family reference.
- 8EI4X5MWS10.XXXX-1 – Single-axis product family reference.
- 8EI2X2MWT10.XXXX-1 – Three-axis product family reference; verify availability.
- 8EI8X8MWT10.XXXX-1 – Three-axis product family reference; verify availability.
- 8EI2X2MWS10.XXXX-1 – Single-axis product family reference; verify availability.
- 8EI8X8MWS10.XXXX-1 – Single-axis product family reference; verify availability.
- 8EAC plug-in module family – Optional ACOPOS P3 expansion and interface modules; select by application.
- 8EXA front-cover/accessory family – Mechanical accessory references; verify the exact cover and connector requirements.
These references cover related ACOPOS P3 configurations and accessories. Similar model names do not establish electrical or functional interchangeability.