Product Description
The B&R 8EI8X8HWT10.0600-1 is a three-axis ACOPOS P3 servo drive designed for high-performance motion control in industrial automation, CNC machinery, and multi-axis production systems. It supports three motor connections, each with a continuous output current rating of 8.8 A, and operates from a three-phase 200–480 V AC supply. Each axis features a digital multi-standard encoder interface for feedback integration with compatible servo motors. The unit includes an integrated braking resistor and supports B&R’s modular plug-in architecture for additional functionality. Its compact wall-mounted design helps reduce control-cabinet space requirements while providing coordinated control of multiple servo axes. This listing identifies the unit as being in mint condition and supplied without a plug. Buyers should confirm the included connector hardware, terminal accessories, and exact system configuration before installation.

Key Product Parameters
- Brand: B&R (Bernecker + Rainer)
- Model: 8EI8X8HWT10.0600-1
- Series: ACOPOS P3
- Product Name: Three-Axis Servo Drive
- Drive Configuration: Three-axis module
- Motor Connections: 3
- Continuous Output Current: 8.8 A per motor connection
- Mains Input Voltage: 3 × 200–480 V AC ±10%
- Mains Frequency: 50/60 Hz ±4%
- Maximum Installed Load: 10 kVA
- Maximum Inrush Current: 45 A
- Continuous Power: Up to 4 kW per motor connection, subject to system operating conditions
- Peak Output Current: Verify the applicable axis-specific datasheet and operating conditions
- Encoder Interface: 1 digital multi-standard encoder interface per axis
- Braking Resistor: Integrated
- DC Bus Capacitance: 470 µF
- Control Supply: 24 V DC ±25%
- Control Supply Current: Approximately 1.2 A plus motor holding-brake current
- Trigger Inputs: 2 electrically isolated inputs
- Temperature Sensor Connections: 3
- Plug-in Module Slots: 1
- Supported Software: B&R Automation Studio / ACP10 drive software; verify version compatibility
- Mounting: Wall mounting, vertical orientation
- Protection Rating: IP20
- Operating Temperature: 5 to 40°C nominal; maximum 55°C subject to derating
- Relative Humidity: 5–85%, non-condensing during operation
- Dimensions: 374 × 66 × 258.5 mm (height × width × depth; wall-mounted configuration)
- Weight: Approximately 4 kg
- Place of Manufacture: B&R, Eggelsberg, Austria (manufacturer location; verify individual unit origin marking)
- Country of Origin: Verify the product nameplate
- Product Status: Mint Condition, as stated in the supplied listing
- Connector Status: Listed as No Plug; confirm exactly which connector or plug components are missing
- Power Requirements: Three-phase 200–480 V AC input and 24 V DC control supply
- Discontinued Status: Not confirmed; check current manufacturer availability
Operating Procedures and Usage Instructions
1. Installation Preparation
- Verify the complete model number and confirm that the unit is the three-axis HWT configuration.
- Check the machine’s required axis count, motor current, voltage, and encoder compatibility.
- Confirm that the cabinet provides sufficient mounting space and cooling airflow.
- Inspect the drive housing, cooling openings, connectors, and terminals.
- Check whether the required power, motor, control, and feedback connector components are included. The listing states that the unit is supplied without a plug.
- Confirm the required upstream line filter and protective devices.
- Isolate all electrical supplies before installation.
2. Mechanical and Electrical Installation
- Mount the drive vertically in the designated control-cabinet position.
- Secure the unit using the specified mounting hardware.
- Connect the three-phase AC input according to the B&R wiring diagram.
- Connect the 24 V DC control supply with correct polarity.
- Connect each servo motor to its designated axis output.
- Connect the compatible encoder feedback cables.
- Connect protective grounding and cable shields.
- Install the required connector and terminal accessories. Do not operate the drive with missing or unsuitable connection hardware.
- Verify the line-filter arrangement and cabinet grounding before energizing the system.
3. Power-On and Commissioning
- Confirm that all motor, encoder, control, and mains connections are secure.
- Check that the motor and encoder assignments correspond to the correct axes.
- Restore power according to the machine manufacturer’s startup procedure.
- Establish communication with the B&R automation controller.
- Use the supported commissioning software to identify the drive and connected motors.
- Configure motor data, encoder settings, current limits, and axis parameters.
- Test each axis individually at reduced speed and load.
- Verify direction of rotation, feedback stability, and drive diagnostics before enabling normal operation.
4. Normal Operation
- Enable the required axes through the machine-control system.
- Monitor motor speed, current, torque demand, and drive status.
- Check encoder feedback and communication status for all three axes.
- Monitor drive temperature and cabinet ventilation.
- Review fault messages and operating conditions regularly.
- Keep each motor within its rated electrical and mechanical limits.
- Avoid simultaneous high-load operation beyond the permitted system power and thermal limits.
5. Parameter Configuration and Modification
- Back up the existing drive and machine configuration before making changes.
- Use the appropriate B&R Automation Studio and supported ACOPOS P3 commissioning tools.
- Confirm the installed software version and drive firmware compatibility.
- Configure the motor identification, encoder type, axis assignment, and control parameters.
- Set current, speed, acceleration, and braking limits according to the connected motor and machine design.
- Verify the braking resistor configuration and thermal operating limits.
- Test each axis after parameter changes and record the approved configuration.
6. Shutdown Procedure
- Stop machine movement and bring all axes to a safe standstill.
- Disable the servo axes through the machine-control system.
- Shut down the automation controller according to the machine procedure.
- Switch off the main AC supply and isolate the 24 V DC control supply.
- Observe the specified DC-bus discharge time.
- Verify that hazardous voltage is absent before disconnecting or servicing the drive.
Daily Maintenance
- Check cabinet ventilation and cooling airflow.
- Inspect the drive housing and ventilation openings for dust accumulation.
- Monitor operating temperature and drive status.
- Check AC input, 24 V DC, motor, and encoder connections.
- Inspect cable shielding and protective grounding.
- Review fault logs for recurring axis or feedback errors.
- Check the integrated braking resistor for signs of overheating or abnormal operation.
- Keep the cabinet clean, dry, and within the specified environmental limits.
- Maintain backups of drive parameters and firmware information.
Troubleshooting
1. Drive Does Not Power On
Check the three-phase input supply, 24 V DC control supply, protective devices, and connection terminals. Verify that the supply voltage is within the specified range.
2. Motor Does Not Respond
Check the axis enable signal, motor power connection, encoder feedback, and controller communication. Verify that the motor is correctly assigned to the axis.
3. Encoder or Feedback Error
Inspect encoder cables, connectors, shielding, and grounding. Confirm that the connected feedback device is supported by the drive configuration.
4. Overcurrent or Axis Fault
Check motor wiring, mechanical load, current limits, and motor parameter settings. Review the diagnostic code before resetting the fault.
5. Drive Overheating
Inspect cabinet airflow, mounting orientation, ambient temperature, and drive loading. Check whether the integrated braking resistor is operating within its specified limits.
6. Communication Failure
Check the controller connection, network configuration, drive identification, and software compatibility. Inspect the communication cables and connector seating.
7. Missing Connector or Plug Hardware
Identify the missing component using the complete drive model and B&R accessory documentation. Obtain the correct connector set before wiring or commissioning; do not substitute connectors based only on physical appearance.
Safety Precautions
- Installation and commissioning must be performed by qualified industrial drive technicians.
- Isolate all electrical supplies before handling the drive.
- Observe the specified DC-bus discharge time and verify safe voltage levels before servicing.
- Never connect or disconnect motor cables while the drive is energized.
- Use the correct line filter, protective devices, connectors, and cable specifications.
- Confirm the three-axis configuration and motor compatibility before commissioning.
- Maintain suitable cabinet ventilation and protective grounding.
- Do not operate the unit with missing or incorrectly rated connector hardware.
- Follow the manufacturer’s instructions for the integrated braking resistor.
- Perform initial testing at reduced speed and load before returning the machine to production.
Product Keywords
B&R 8EI8X8HWT10.0600-1, ACOPOS P3 servo drive, B&R three-axis servo amplifier, 8.8 A servo drive, 3-axis motion controller, 200–480 V AC servo drive, B&R industrial motion control, integrated braking resistor, digital encoder interface, B&R automation system, industrial CNC drive, multi-axis servo controller, control cabinet servo amplifier, industrial automation spare parts.
Product information: https://www.newplcdcs.com
15 Related B&R ACOPOS P3 Models
The following are related ACOPOS P3 drive configurations and product families. Their axis count, current rating, mounting style, and connection arrangement differ, so they should not be treated as automatic replacements.
- 8EI2X2HWT10 Series – Three-Axis ACOPOS P3 Drive, 2.2 A Class
- 8EI4X5HWT10 Series – Three-Axis ACOPOS P3 Drive, 4.5 A Class
- 8EI8X8HWT10 Series – Three-Axis ACOPOS P3 Drive, 8.8 A Class
- 8EI2X2HWD10 Series – Two-Axis ACOPOS P3 Drive, 2.2 A Class
- 8EI4X5HWD10 Series – Two-Axis ACOPOS P3 Drive, 4.5 A Class
- 8EI8X8HWD10 Series – Two-Axis ACOPOS P3 Drive, 8.8 A Class
- 8EI1X6HWS10 Series – Single-Axis ACOPOS P3 Drive, 1.6 A Class
- 8EI2X2HWS10 Series – Single-Axis ACOPOS P3 Drive, 2.2 A Class
- 8EI4X5HWS10 Series – Single-Axis ACOPOS P3 Drive, 4.5 A Class
- 8EI8X8HWS10 Series – Single-Axis ACOPOS P3 Drive, 8.8 A Class
- 8EI8X8HCT10 Series – Three-Axis ACOPOS P3 Cold-Plate Drive
- 8EI8X8HCS10 Series – ACOPOS P3 Cold-Plate Drive Family
- 8EI013HWT10 Series – ACOPOS P3 Higher-Current Drive Family
- 8EI017HWT10 Series – ACOPOS P3 Higher-Current Drive Family
- 8EI8X8HWD10.0600-1 – Two-Axis 8.8 A ACOPOS P3 Drive Reference
Verify the complete order number, axis count, current rating, mounting type, connector arrangement, and braking-resistor configuration before selecting a related model as a replacement.