Product Description
The B&R ACOPOS P3 8EI8X8HWT10.0600-1 is a high-performance three-axis servo drive designed for advanced industrial motion control and multi-axis automation systems. It supports three motor connections with a rated continuous current of 8.8 A per axis and operates with a three-phase 200–480 VAC input supply. Each axis features a digital multi-standard encoder interface for precise motor feedback and coordinated positioning. The unit includes an integrated braking resistor, a dynamic node allocation function, and a modular plug-in interface for system expansion. Its wall-mounting design makes it suitable for packaging machinery, automated assembly equipment, CNC systems, robotics, and synchronized production lines. The drive supports B&R automation platforms and ACP10 software, providing configuration and commissioning functions for connected servo motors. With its compact 66 mm width and three-axis architecture, it offers a practical solution for applications requiring multiple synchronized motion axes. This listing identifies the unit as Mint Condition, subject to physical inspection and verification of included accessories.

Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | B&R Industrial Automation |
| Model | 8EI8X8HWT10.0600-1 |
| Series | ACOPOS P3 |
| Product Name | Three-Axis Servo Drive / Servo Amplifier |
| Place of Manufacture | Eggelsberg, Austria (manufacturer location; actual production origin unverified) |
| Product Status | Mint Condition (seller-listed) |
| Dimensions | 374 × 66 × 258.5 mm (H × W × D) |
| Weight | Approx. 4 kg |
| Country of Origin | Not independently verified |
| Power Requirements | 3 × 200–480 VAC ±10%, 50/60 Hz |
| Rated Output Current | 3 × 8.8 A |
| Number of Axes | 3 |
| Continuous Power | 4 kW |
| DC Bus Capacitance | 470 µF |
| Braking Resistor | Integrated |
| Protection Rating | IP20 |
| Cooling / Installation | Wall mounting |
| Operating Temperature | 5 to 40°C nominal; maximum 55°C |
| Supported Software | ACP10 V3.12.1 |
| Discontinued | Current lifecycle status requires manufacturer confirmation |
⚙️ Operating Procedures and Usage Instructions
1. Installation and Preparation
- Verify the complete model number and hardware revision.
- Inspect the enclosure, power terminals, motor connectors, and cooling surfaces.
- Mount the drive vertically in the approved wall-mounting position.
- Maintain sufficient clearance for ventilation and maintenance.
- Connect the three-phase AC input according to the wiring diagram.
- Connect protective earth (PE).
- Connect the three compatible servo motors to their designated axis terminals.
- Connect the appropriate encoder feedback cables for each axis.
- Connect the 24 VDC control supply.
- Install the required upstream line filter and external electrical protection.
- Verify motor brake wiring, grounding, and cable shielding.
2. Power-On Sequence
- Confirm that all connected motors are mechanically secured.
- Check the incoming AC voltage and protective grounding.
- Verify the motor power and encoder connections.
- Confirm that the emergency-stop and safety circuits are operational.
- Energize the 24 VDC control supply.
- Apply the main three-phase AC supply.
- Allow the ACOPOS P3 drive to complete initialization.
- Check the status indicators and controller communication.
- Verify encoder feedback and motor identification for all three axes.
- Enable the servo axes individually after confirming normal operating conditions.
Observe the manufacturer’s specified switch-on interval, typically 60 seconds. Do not repeatedly cycle the power supply.
3. Normal Operating Procedure
- Open the machine control application.
- Confirm that the ACOPOS P3 drive is ready.
- Check the status of all three motor axes.
- Verify feedback signals and motor direction.
- Select the approved operating mode.
- Set the required speed, torque, and positioning commands.
- Enable each axis through the machine controller.
- Perform a low-speed movement test.
- Verify synchronization and positioning accuracy.
- Start the automatic production sequence.
- Monitor current, temperature, alarms, and motor performance during operation.
4. Parameter Configuration and Modification
- Connect to the B&R automation system using compatible engineering software.
- Use the supported ACP10 software version and verify compatibility with the installed hardware.
- Read and back up the existing drive configuration.
- Configure the correct motor identification for each axis.
- Select the appropriate digital encoder feedback interface.
- Configure motor current, speed, torque, and acceleration limits according to motor specifications.
- Set the required control-loop parameters.
- Configure motor holding brake outputs where applicable.
- Verify trigger inputs and temperature sensor connections.
- Check the braking resistor configuration and regenerative energy requirements.
- Save the configuration and perform individual axis commissioning tests.
Do not apply parameter sets from other servo drive models without checking electrical and feedback compatibility.
5. Shutdown Sequence
- Stop the automatic production cycle.
- Command all three axes to decelerate.
- Confirm that all motors have stopped.
- Disable the servo enable commands.
- Confirm that the motor holding brakes operate as intended.
- Remove the main AC supply according to the machine shutdown procedure.
- Switch off the 24 VDC control supply when required.
- Wait for the DC bus to discharge.
- Verify the DC bus voltage using an appropriate measuring instrument.
- Apply lockout/tagout procedures before maintenance.
🔧 Daily Maintenance and Troubleshooting
- Inspect motor power and encoder cables for damage.
- Check terminal connections and protective grounding.
- Keep ventilation surfaces free from dust and contamination.
- Monitor the temperature of the drive during operation.
- Check for overcurrent, overvoltage, and encoder communication alarms.
- Inspect motor holding brake connections.
- Check braking resistor operation and regeneration conditions.
- Verify that all three axes maintain correct positioning and synchronization.
- Investigate abnormal noise, vibration, or unexpected motor heating.
- Back up drive configurations before software or parameter changes.
⚠️ Safety Precautions
- Installation and commissioning must be performed by qualified personnel.
- The drive contains hazardous AC and DC voltages.
- Never disconnect motor or encoder cables while energized.
- Allow the DC bus to discharge according to the manufacturer’s instructions.
- Use suitable upstream line filtering and electrical protection.
- Ensure correct protective grounding.
- Do not exceed the rated current of 8.8 A per axis.
- Observe the IP20 protection rating; install the unit inside a suitable electrical enclosure.
- Verify the braking resistor and regenerative energy configuration before operation.
- Do not bypass emergency-stop or safety functions.
🔗 Product Keywords
B&R 8EI8X8HWT10.0600-1, ACOPOS P3 Servo Drive, Three-Axis Servo Amplifier, 8.8 A Servo Drive, 200–480 VAC, Digital Encoder Interface, Integrated Braking Resistor, Industrial Motion Controller, B&R Automation.
Industrial automation products and replacement spare parts: https://www.newplcdcs.com
Recommended B&R Models
- B&R 8EI2X2HWT10.0600-1 – ACOPOS P3 Three-Axis Servo Drive
- B&R 8EI4X5HWT10.0600-1 – ACOPOS P3 Three-Axis Servo Drive
- B&R 8EI8X8HWT10.0600-1 – ACOPOS P3 Three-Axis Servo Drive
- B&R 8EI8X8HWS10.0600-1 – ACOPOS P3 Single-Axis Servo Drive
- B&R 8EI4X5HWS10.0600-1 – ACOPOS P3 Single-Axis Servo Drive
- B&R 8EI2X2HWS10.0600-1 – ACOPOS P3 Single-Axis Servo Drive
- B&R 8EI8X8HWT10.XXXX-1 – ACOPOS P3 Three-Axis Drive Family
- B&R 8EI4X5HWT10.XXXX-1 – ACOPOS P3 Three-Axis Drive Family
- B&R 8EI2X2HWT10.XXXX-1 – ACOPOS P3 Three-Axis Drive Family
- B&R 8EAD0000.000-1 – ACOPOS P3 LCD Display Module
- B&R 8EXA200.0010-00 – ACOPOS P3 Front Cover
- B&R 8EXA200.0020-00 – ACOPOS P3 Front Cover
- B&R 8BVP0880HW00.008-1 – ACOPOSmulti Power Supply Module
- B&R 8BVI0014HWD0.000-1 – ACOPOSmulti Inverter Module
- B&R 8B0C0440HW00.000-1 – ACOPOSmulti Drive Module