Product Description
The Bosch Rexroth 4WRGE10V100L-13 is a two-stage, electrically operated high-response proportional directional control valve designed for precision hydraulic motion control. Belonging to the 4WRGE valve family, it combines a servo-operated pilot stage with integrated electronic control and main-spool position feedback to provide accurate flow direction and regulation. The valve is suitable for closed-loop position, speed, pressure, and force control in industrial hydraulic systems requiring fast response and precise actuator movement. Typical applications include hydraulic presses, injection molding machines, steel processing equipment, machine tools, and automated production machinery. The 4WRGE series supports nominal size 10 configurations, with flow ratings selected according to the valve spool and configuration. Before installation, verify the complete valve type code, hydraulic port arrangement, rated flow, supply voltage, command signal, pilot oil configuration, and seal material to ensure compatibility with the existing hydraulic circuit.

📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | Bosch Rexroth |
| Model | 4WRGE10V100L-13 |
| Material Number | R900895145 |
| Additional Part Number | R900771334 |
| Series | 4WRGE Series 1X |
| Product Name | Two-Stage High-Response Proportional Directional Valve |
| Valve Type | Electrically Operated 4/3-Way Directional Valve |
| Nominal Size | NG10 |
| Nominal Flow Rate | 100 L/min at 10 bar valve pressure differential |
| Maximum Operating Pressure | 315 bar |
| Maximum Flow | Up to 170 L/min for size 10 |
| Supply Voltage | 24 V DC for G24 configuration |
| Control Electronics | Integrated |
| Main Spool Feedback | Inductive position transducer |
| Control Applications | Position, Speed, Pressure, and Force |
| Dimensions | Refer to the manufacturer’s NG10 installation drawing |
| Weight | Approximately 8 kg for NG10 series |
| Country of Origin | Germany; verify individual unit nameplate |
| Product Status | Used / condition subject to seller confirmation |
| Discontinued | Current status of this exact configuration requires manufacturer confirmation |
⚙️ Operating Procedures and Usage Instructions
1. Installation and Preparation
- Inspect the valve body, mounting surface, electrical connector, and pilot control assembly.
- Verify the material number R900895145 and the complete type code.
- Check the hydraulic manifold mounting pattern and port alignment.
- Clean all hydraulic connections before installation.
- Confirm the hydraulic fluid type, viscosity, and cleanliness.
- Install the valve using the specified mounting bolts and tightening torque.
- Connect the pressure, tank, and actuator ports according to the hydraulic circuit diagram.
- Connect the pilot oil supply and return according to the selected configuration.
- Connect the 24 V DC power supply and command signal using the correct electrical pin assignment.
- Verify protective grounding and cable shielding.
2. Power-On Sequence
- Confirm that the hydraulic actuator and connected machinery are in a safe condition.
- Check the hydraulic oil level and filtration system.
- Verify that the hydraulic pressure is within the permitted operating range.
- Check the 24 V DC electrical supply and polarity.
- Energize the control electronics according to the machine procedure.
- Start the hydraulic power unit with the valve command at its approved neutral value.
- Allow the hydraulic system to circulate and stabilize.
- Check for oil leakage, abnormal noise, and unstable pressure.
- Verify the command signal and valve response.
- Enable automatic operation only after all safety and feedback checks are completed.
3. Normal Operating Procedure
- Confirm that the valve and hydraulic system are correctly configured.
- Verify the controller command signal and electrical connections.
- Check the actual actuator position and feedback signals.
- Apply a low-level command signal to test spool response.
- Confirm the correct flow direction and actuator movement.
- Increase the command gradually within the approved operating limits.
- Monitor hydraulic pressure, actuator speed, and system temperature.
- Check for oscillation, pressure fluctuations, or abnormal valve response.
- Run the normal automatic sequence after successful commissioning.
- Record operating parameters and diagnostic observations.
4. Parameter Configuration and Modification
- Use the compatible Rexroth commissioning equipment and documentation for the installed valve configuration.
- Verify the electronic interface before connecting the control system.
- Confirm the command signal type, including voltage or current interface.
- Check the zero-point setting and spool response.
- Verify the hydraulic flow characteristic and control direction.
- Adjust the connected motion controller’s gain and response settings according to the application.
- Confirm that pressure, speed, and position limits remain within the approved hydraulic design.
- Test the valve at reduced command levels after parameter changes.
- Do not apply parameter settings from another 4WRGE configuration without checking hardware compatibility.
5. Shutdown Sequence
- Stop the automatic hydraulic process.
- Reduce the valve command gradually to the approved neutral condition.
- Bring the hydraulic actuator to a safe position.
- Confirm that all mechanical movement has stopped.
- Disable the valve command and associated control signals.
- Shut down the hydraulic power unit according to the machine procedure.
- Isolate the 24 V DC supply when electrical maintenance is required.
- Relieve stored hydraulic pressure before removing the valve or hydraulic connections.
🔧 Daily Maintenance and Troubleshooting
- Inspect the valve body and hydraulic fittings for oil leakage.
- Check electrical connectors and cable shielding.
- Monitor hydraulic oil cleanliness and filter condition.
- Check for abnormal pressure fluctuations and actuator oscillation.
- Investigate slow response by checking pilot pressure and hydraulic contamination.
- Check the command signal if the valve does not respond correctly.
- Inspect the feedback and integrated electronics if positioning becomes unstable.
- Check the hydraulic neutral condition if the actuator drifts unexpectedly.
- Replace damaged seals and filters with compatible specified components.
- Maintain records of operating pressure, oil temperature, and maintenance activities.
⚠️ Safety Precautions
- Installation and servicing must be performed by qualified hydraulic technicians.
- Hydraulic pressure can remain stored after the power unit is switched off.
- Never loosen hydraulic connections under pressure.
- Do not disconnect electrical connectors while energized.
- Verify valve port identification before connecting pressure and return lines.
- Maintain the specified oil cleanliness to protect the pilot stage.
- Never exceed the rated pressure or flow limits.
- Confirm actuator safety and load support before commissioning.
- Do not change control parameters without reviewing the complete hydraulic system.
🔗 Product Keywords and Information
Bosch Rexroth R900895145, R900771334, 4WRGE10V100L-13, 4WRGE10, High Response Proportional Valve, Hydraulic Directional Control Valve, NG10 Hydraulic Valve, 24 V DC Hydraulic Valve, Integrated Electronics, Industrial Hydraulic Motion Control.
For industrial hydraulic valves, automation components, and replacement spare parts, visit:
Recommended Bosch Rexroth Models
- 4WRGE10V50L-1X/315G24K31
- 4WRGE10V100L-1X/315G24K31
- 4WRGE10V1-50L-1X/315G24K31
- 4WRGE10V1-100L-1X/315G24K31
- 4WRGE10V100L-1X/315G24ETK31
- 4WRGE10V50L-1X/315G24ETK31
- 4WRGE10E50L-1X/315G24EK31
- 4WRGE10Q2-100L-1X/315G24ETK31
- 4WRGE16V125L-1X/315G24K31
- 4WRGE16V200L-1X/315G24K31
- 4WRGE16V1-125L-1X/315G24K31
- 4WRGE16V1-200L-1X/315G24K31
- 4WRGE25V250L-1X/315G24K31
- 4WRGE25V1-250L-1X/315G24K31
- 4WRGE25V350L-1X/315G24K31
Note: Recommended models belong to the Bosch Rexroth 4WRGE family. Flow ratings, spool characteristics, electrical interfaces, and hydraulic connections differ. They should not be treated as direct replacements without checking the complete type code.