1. Product Description
The GENERAL ELECTRIC DS200SLCCG4A is a LAN Communications Card designed for GE Mark V Speedtronic drive and control systems. Identified by the functional acronym SLCC, the board provides a communication interface between the drive control system and its Local Area Network (LAN) functions. It incorporates an integrated LAN Control Processor (LCP), dual-ported RAM for data exchange with the host drive control card, and two EPROM memory modules for processor program storage. The board also includes isolated and non-isolated interface circuitry, configurable hardware jumpers, and provision for an attachable alphanumeric keypad for diagnostics and local access. The Group 4 version does not include DLAN or ARCNET circuitry, an important distinction when selecting a replacement for an existing installation.

2. Key Technical Specifications
- Brand: General Electric (GE)
- Model: DS200SLCCG4A
- Series: Mark V DS200
- Functional Acronym: SLCC
- Product Name: LAN Communications Card
- Product Type: Printed Circuit Board / Communication Interface Card
- Primary Function: LAN communication processing and drive-control data exchange
- Main Processor: Integrated LAN Control Processor (LCP)
- Memory: Two removable EPROM modules and dual-ported RAM
- Interface Circuitry: Isolated and non-isolated circuits
- Configuration Hardware: Berg-type jumpers and wire jumpers
- Diagnostic Interface: Attachable alphanumeric keypad
- Network Hardware: Group 4 configuration without DLAN or ARCNET circuitry
- Associated Control Board: SDCC Drive Control Card
- Instruction Manual: GEI-100162
- PCB Coating: Normal coating, supplier-reported
- Place of Manufacture: Not independently verified for this individual unit
- Product Status: Legacy / discontinued product family; current availability depends on surplus or refurbished inventory
- Dimensions: Not officially verified for this exact part number
- Weight: Not officially published
- Country of Origin: Not independently verified for this individual unit
- Power Requirements: Receives its required DC operating supplies through the control-system interface; exact board-level ratings should be confirmed in GEI-100162
- Discontinued: Confirm current manufacturer support and availability before purchase
3. Application Scenarios
The DS200SLCCG4A is used in compatible GE Mark V drive and excitation control installations that require LAN communication processing and data exchange with the host control board.
Typical application scenarios include:
- GE Mark V drive-control cabinets
- Compatible GE turbine and excitation control installations
- Communication between the LAN Control Processor and the host SDCC card
- Legacy drive-system communication maintenance
- Troubleshooting and restoration of Mark V control networks
- Replacement of a failed Group 4 SLCC card where the original hardware configuration matches
The Group 4 designation is particularly important: unlike Group 1 and Group 2 SLCC versions, the Group 4 card does not include DLAN or ARCNET circuitry. Confirm the required communication architecture before selecting this board.
4. Installation and Operating Procedures
- Preparation: Confirm the complete DS200SLCCG4A part number, revision, control-system application, and required communication configuration. Review GEI-100162 and the equipment-specific drawings.
- Shutdown: Stop the associated drive or control equipment using the approved procedure. Isolate relevant power sources and apply lockout/tagout.
- ESD protection: Wear a grounded wrist strap and use an ESD-safe work surface before handling the PCB.
- Documentation: Photograph the original board, connector positions, EPROM locations, and all Berg-type and wire jumper settings.
- Removal: Carefully disconnect the board interfaces and remove the existing card without damaging the rack or connector contacts.
- Inspection: Check the replacement board for corrosion, damaged components, loose EPROM modules, and connector defects.
- Configuration: Compare the replacement board’s jumper and EPROM configuration with the approved application records. Do not assume factory settings are suitable for every installation.
- Installation: Insert the card in the specified rack position and reconnect all interfaces according to the original wiring documentation.
- Power-up: Restore power only after the installation has been inspected and the equipment is cleared for energization.
- Communication verification: Check LCP operation, communication with the host SDCC card, diagnostic status, and the applicable LAN functions.
- Operational testing: Confirm that the drive or excitation system operates normally and that no unresolved communication alarms remain before returning the equipment to service.
5. Parameter Configuration
The DS200SLCCG4A uses programmed processor memory and physical hardware configuration. It is not a general-purpose network switch or an independent Ethernet controller.
Important configuration elements include:
- EPROM modules: Store the LCP program data. Verify software identity and compatibility before transferring or replacing memory modules.
- Dual-ported RAM: Provides the data-exchange interface between the LCP and the host drive control card.
- Berg-type jumpers: Provide hardware configuration options that must match the installed application.
- Wire jumpers: Support specified factory or application configuration options.
- Group 4 architecture: Does not include DLAN or ARCNET circuitry. Do not assume these network functions are available on this card.
- Alphanumeric keypad: Can provide local diagnostic access when the appropriate keypad and system configuration are available.
Refer to GEI-100162 and the original controller configuration records before changing any jumper, memory module, or communication setting. Preserve the original configuration wherever possible.
6. Daily Maintenance and Inspection
- Inspect the control cabinet for dust, moisture, excessive temperature, and vibration.
- Check the PCB for corrosion, discoloration, damaged components, and loose hardware.
- Inspect the card-edge and cable connectors for contamination or mechanical damage.
- Check that EPROM modules are securely seated.
- Verify that jumper positions match the approved configuration record.
- Monitor communication alarms and diagnostic messages from the drive control system.
- Check the keypad interface, if installed, for normal diagnostic access.
- Maintain proper cabinet ventilation and grounding.
- Record recurring communication faults and maintenance activities.
7. Troubleshooting Guide
Problem: LAN communication is unavailable
Check the control-system wiring, interface connections, LCP status, and host SDCC communication path. Confirm that the installed network architecture is supported by the Group 4 card.
Problem: Communication with the SDCC card fails
Inspect the board connection, dual-ported RAM interface, processor status, and applicable control-system diagnostics. Verify that the correct SLCC configuration is installed.
Problem: Board fails to initialize
Check the EPROM modules, board seating, supply conditions, and hardware jumper settings. Use the approved GE diagnostic procedure to isolate the fault.
Problem: Keypad does not respond
Check the keypad connection and compatibility with the installed board and control-system configuration. Confirm whether the keypad is supported in the specific application.
Problem: Intermittent communication alarms
Inspect connectors, grounding, cable routing, cabinet environmental conditions, and the associated network interfaces. Review the alarm history to identify whether the fault is board-specific or system-wide.
Problem: Replacement board does not operate correctly
Verify the full part number, revision, Group 4 configuration, EPROM identity, jumper settings, and compatibility with the host control board. A different SLCC group may have a different communication hardware configuration.
8. Safety Precautions
- Installation and troubleshooting must be performed by qualified industrial drive or turbine-control technicians.
- Follow the approved shutdown, electrical isolation, and lockout/tagout procedures.
- Verify that the control cabinet is electrically safe before accessing internal components.
- Use ESD protection when handling the PCB and EPROM modules.
- Never insert or remove the board while energized unless an explicitly approved procedure permits it.
- Do not change firmware, jumpers, or communication settings without verified documentation.
- Do not assume Group 4 supports DLAN or ARCNET.
- Complete all required communication and functional checks before returning the equipment to service.
9. Recommended Related GE Models
The following models are related GE Mark V communication, drive-control, and interface boards. They may be useful for maintenance inventory and system-level troubleshooting, but they are not confirmed direct replacements for DS200SLCCG4A. Verify the exact function, revision, network architecture, and hardware configuration before ordering.
- DS200SLCCG1A – LAN Communications Card, Group 1
- DS200SLCCG2A – LAN Communications Card, Group 2
- DS200SLCCG3A – LAN Communications Card family variant
- DS200SLCCG4REG – SLCC Group 4 Communication Card variant
- DS215SLCCG4A – LAN Communications Card
- DS200SDCCG1A – Drive Control Card
- DS200SDCCG4A – Drive Control Card
- DS200SPCBG1A – Multi-Bridge Signal Processing Card
- DS200LDCCH1A – Drive Control/LAN Interface Board
- DS200IMCPG1A – Power Supply/Interface Board
- DS200DCFBG1A – DC Power Supply Board
- DS200PCCAG1A – Power Connect Card
- DS200TBQDG1A – RST Extension Analog Termination Board
- DS200TCQAG1A – Analog I/O Board
- DS200TCQBG1BCA – RST Extended Analog I/O Board
10. Purchasing and Verification Notes
Before purchasing, request clear photographs of the actual DS200SLCCG4A board, including its complete identification label, revision markings, EPROM modules, jumper positions, connectors, and component side.
Confirm whether the item is unused surplus, open-box, or refurbished. Ask the seller to clarify the testing performed, warranty coverage, and return conditions.
For replacement applications, verify that the original installation uses the Group 4 SLCC configuration. In particular, confirm that the system does not require DLAN or ARCNET circuitry provided by other SLCC groups. Check the EPROM identity, jumper settings, and host SDCC compatibility before installation.