The Bosch Rexroth HMD01.1N-W0020-A-07 (R911295322) is an IndraDrive M modular double-axis inverter designed to control two independent motor axes in industrial motion-control systems. It operates as part of a modular drive configuration, receiving DC-bus power from a compatible IndraDrive supply unit and converting it into controlled three-phase AC output for connected motors. The W0020 version provides a continuous current rating of 10 A per axis and a maximum current rating of 20 A per axis under the specified operating conditions. The unit uses internal air cooling and requires an external 24 V DC control supply. Typical applications include machine tools, packaging equipment, material-handling systems, and coordinated multi-axis machinery. Before installation or replacement, verify the complete type code, firmware and control-unit compatibility, DC-bus configuration, motor data, encoder connections, and cabinet cooling requirements.

📋 Product Specifications
| Parameter | Description |
|---|---|
| Brand | Bosch Rexroth / Indramat |
| Model | HMD01.1N-W0020-A-07 |
| Material Number | R911295322 |
| Product Type | Double-Axis Inverter |
| Series | IndraDrive M |
| Axis Configuration | 2 motor axes |
| Continuous Current | 10 A per axis |
| Maximum Current | 20 A per axis |
| External Control Voltage | 24 V DC ±20% |
| Control Power Consumption | 17 W, excluding control unit and motor brake |
| DC-Bus Input | 254–750 V DC, system-dependent |
| Output Voltage | Up to 530 V AC, three-phase |
| Cooling Method | Internal air cooling |
| Protection Rating | IP20 |
| Dimensions | 50 × 440 × 309 mm (W × H × D) |
| Weight | Approx. 5.7 kg; supplier listings may report different packaged weights |
| Place of Manufacture | Not confirmed |
| Country of Origin | Verify product nameplate or shipping documentation |
| Product Status | Legacy IndraDrive M component; current availability varies |
| Discontinued | Not confirmed |
⚙️ Installation and Operation
- Installation: Isolate the drive system and confirm that the DC bus is discharged before handling the inverter. Install the module in the designated control cabinet position, ensuring correct mechanical mounting, DC-bus connections, grounding, and cooling clearance. Connect both motor axes according to the official wiring diagrams.
- Power-On: Verify the compatible IndraDrive supply unit, DC-bus connections, external 24 V DC control supply, and motor wiring. Apply power following the system commissioning procedure and check the drive and supply-unit diagnostic indicators.
- Normal Operation: Monitor both motor axes independently. Check current demand, motor temperature, encoder feedback, drive status, and fault messages through the compatible Bosch Rexroth control and commissioning environment.
- Parameter Configuration: Configure motor data, encoder settings, current limits, control loops, and axis operating parameters using the appropriate Rexroth engineering software and system documentation. Back up existing parameters before making changes.
- Power-Off: Stop both axes using the machine’s approved shutdown sequence. Disable the drive, isolate the mains and DC-bus supply, and verify that the DC bus has discharged before servicing.
🔧 Maintenance and Troubleshooting
- Drive fails to start: Check the external 24 V DC control supply, DC-bus voltage, enable signals, and system fault messages.
- Overcurrent fault: Inspect motor cables, motor insulation, mechanical loading, and configured current limits.
- Overtemperature alarm: Check the internal blower, cabinet airflow, ambient temperature, and ventilation openings.
- Motor feedback fault: Inspect encoder cables, connectors, feedback configuration, and motor compatibility.
- Communication or configuration fault: Verify the control unit, firmware version, parameter set, and drive-system configuration.
- One axis operates abnormally: Check that axis-specific motor connections, feedback signals, and parameters are assigned correctly.
🛡️ Safety Precautions
- Installation and commissioning must be performed by qualified drive-system personnel.
- High DC-bus voltages are hazardous. Isolate the supply and observe the manufacturer’s discharge waiting time before servicing.
- Never disconnect motor cables while the drive is energized.
- Confirm motor voltage, current, encoder type, and braking requirements before connecting equipment.
- Maintain the specified cabinet ventilation and cooling clearance.
- Do not assume that similar HMD models or later-generation drive units are direct replacements.
- Perform functional checks and verify machine safety functions before returning the equipment to production.
🔗 Related Bosch Rexroth Models
The following models belong to related IndraDrive M drive and power-unit families. They are reference models, not guaranteed direct replacements for R911295322.
- Bosch Rexroth HMD01.1N-W0012
- Bosch Rexroth HMD01.1N-W0036
- Bosch Rexroth HMD01.1N-W0020-A-07-NNNN
- Bosch Rexroth HMD01.1N-W0012-A-07-NNNN
- Bosch Rexroth HMD01.1N-W0036-A-07-NNNN
- Bosch Rexroth HMS01.1N-W0036
- Bosch Rexroth HMS01.1N-W0070
- Bosch Rexroth HMS01.1N-W0150
- Bosch Rexroth HMV01.1E-W0030
- Bosch Rexroth HMV01.1E-W0075
- Bosch Rexroth HCS02.1E-W0012
- Bosch Rexroth HCS02.1E-W0028
- Bosch Rexroth HCS03.1E-W0070
- Bosch Rexroth HCS03.1E-W0100
- Bosch Rexroth HCS03.1E-W0150