Product Description
The B&R ACOPOSmulti 8BVP0220HW00.000-1, also designated P0220, is a wall-mounted power supply module designed for the ACOPOSmulti modular servo drive system. It converts three-phase AC input power into the DC bus supply required by connected drive modules and supports regenerative operation, allowing energy generated during motor deceleration to be returned to the power supply system. The module provides a nominal 750 VDC DC bus, a continuous supply and regenerative power rating of 15 kW, and a peak rating of 37.5 kW. It includes two slots for ACOPOSmulti plug-in modules, an integrated temperature-sensor connection, and 24 VDC auxiliary supply functions. Its wide input voltage range supports industrial power systems from 220 to 480 VAC. The module is intended for compatible ACOPOSmulti installations and requires the correct terminal block set, grounding, shielding, cooling, and DC bus configuration. The listed unit is marked Revision M0; verify the hardware revision and system compatibility before replacement.

Product Datasheet
- Brand: B&R Automation
- Model: 8BVP0220HW00.000-1
- Short Model Designation: P0220
- Product Name: ACOPOSmulti Power Supply Module
- Product Series: ACOPOSmulti
- Product Type: Regenerative Servo Drive Power Supply
- Mounting Type: Wall Mounting
- Rated Output Current: 22 A
- AC Input Voltage: 3 × 220–480 VAC ±10%
- Input Frequency: 50/60 Hz ±4%
- Maximum Connected Power: 15.6 kW
- DC Bus Nominal Voltage: 750 VDC
- Continuous Power: 15 kW
- Peak Power: 37.5 kW
- Regenerative Operation: Supported
- Power Factor Correction: Supported
- Nominal Switching Frequency: 5 kHz
- Selectable Switching Frequencies: 5 kHz / 10 kHz
- Plug-In Module Slots: 2
- Auxiliary Supply Input: 25 VDC ±1.6%
- 24 VDC Auxiliary Output: 24 VDC ±6% under specified DC bus conditions
- Protection Rating: IP20
- Cooling and Mounting: Wall-mounted configuration
- Dimensions: 263 × 106.5 × 317 mm (Depth × Width × Height)
- Weight: Approximately 5.2 kg
- Operating Temperature: 5 to 40°C nominal; maximum 55°C
- Storage Temperature: -25 to 55°C
- Product Revision: M0, as stated in the seller listing
- Country of Origin: Not verified
- Product Lifecycle: Check current B&R product support information
- Condition: Used, according to the seller listing
Operating Guidelines and Usage
- Confirm that the installed drive system belongs to the B&R ACOPOSmulti family and supports the 8BVP0220HW00.000-1 power supply.
- Verify the three-phase input voltage, frequency, protective earth, and upstream circuit protection.
- Check the DC bus voltage and total connected drive-module power against the system design.
- Confirm that the two plug-in module slots contain the correct accessories for the application.
- Install the specified terminal block set and verify all power and auxiliary connections.
- Connect the regenerative energy path according to the approved ACOPOSmulti wiring design.
- Check the cooling arrangement, mounting orientation, and cabinet ventilation.
- Verify that the drive system reports normal power-supply and DC bus status before enabling motor operation.
Power-On and Power-Off Sequence
Power-On
- Confirm that all drive modules and DC bus connections are correctly installed.
- Verify protective earth, input wiring, shielding, and terminal tightness.
- Check that the connected motor drives and loads are ready for startup.
- Apply the specified three-phase AC supply according to the B&R startup procedure.
- Allow the DC bus charging sequence to complete.
- Check the module status and system diagnostics.
- Enable the connected servo drives only after the power supply and DC bus are confirmed normal.
Power-Off
- Stop all connected motors using the approved machine shutdown procedure.
- Disable the servo drives and remove operating commands.
- Isolate the AC input supply.
- Allow the DC bus to discharge according to the manufacturer’s specified waiting time.
- Verify DC bus voltage with an appropriately rated measuring instrument before servicing.
- Disconnect power and auxiliary wiring only after confirming electrical isolation.
Normal Operating Procedure
- Monitor DC bus voltage and power-supply status during operation.
- Keep the module within its specified input voltage and ambient temperature limits.
- Monitor regenerative operation during frequent deceleration or high-inertia applications.
- Ensure that the connected drive modules remain within the power supply’s continuous and peak ratings.
- Maintain adequate ventilation around the wall-mounted unit.
- Inspect power terminals, protective earth connections, and cable shielding during scheduled maintenance.
- Record module revision, system configuration, and relevant drive parameters after maintenance.
Parameter Settings and Modification
The 8BVP0220HW00.000-1 operates as part of the ACOPOSmulti drive system. Configuration should follow the applicable B&R hardware documentation and engineering software requirements.
- Verify the permitted input voltage and DC bus operating range.
- Confirm the switching frequency selected for the installed drive configuration.
- Check the connected module power demand and regenerative energy requirements.
- Verify the auxiliary 24 VDC supply load.
- Confirm temperature-sensor connections and associated monitoring functions.
- Check the hardware revision against the Automation Studio hardware upgrade requirements.
- Do not modify internal power-stage components or protection circuits without manufacturer-approved service instructions.
Maintenance and Troubleshooting
Routine Maintenance
- Inspect the housing and cooling surfaces for dust accumulation.
- Check power terminals for discoloration, loose connections, or overheating.
- Inspect protective earth and cable shielding connections.
- Check the condition of the cooling fan and associated airflow path where fitted.
- Inspect the DC bus connections and connected drive modules.
- Review system diagnostics for overvoltage, undervoltage, overtemperature, or overload events.
- Verify that cabinet temperature and humidity remain within the specified operating conditions.
Common Troubleshooting Checks
- Power supply does not start: Check three-phase AC input, protective devices, wiring, and the DC bus charging circuit.
- DC bus undervoltage: Verify input voltage, connected load, and supply-side connections.
- DC bus overvoltage: Check regenerative operation, braking conditions, and system energy-management configuration.
- Overtemperature alarm: Inspect cabinet ventilation, cooling components, ambient temperature, and load conditions.
- Intermittent operation: Check terminal tightness, grounding, shielding, and supply stability.
- Plug-in module recognition fault: Verify module installation, slot compatibility, and hardware configuration.
Safety Precautions
- Installation and maintenance must be performed by qualified industrial electrical personnel.
- The module operates with hazardous three-phase AC and high-voltage DC bus circuits.
- Always isolate the AC supply and verify DC bus discharge before servicing.
- Never disconnect DC bus connections while energized.
- Use the specified terminal blocks, cable cross-sections, protective devices, and grounding arrangements.
- Maintain the required clearances and approved mounting orientation.
- Do not exceed the rated continuous or peak power limits.
- Follow B&R ACOPOSmulti documentation for commissioning, fault recovery, and replacement procedures.
Recommended B&R Related Models
The following components belong to the B&R ACOPOSmulti drive and automation product families. They are related system components and spare-parts references, not all direct replacements for the 8BVP0220HW00.000-1.
- 8BVP0440HW00.000-1 – ACOPOSmulti 44 A Power Supply Module
- 8BVP0880HW00.000-1 – ACOPOSmulti 88 A Power Supply Module
- 8BVP0220HC00.000-1 – ACOPOSmulti 22 A Cold-Plate Power Supply Module
- 8BVP0440HC00.000-1 – ACOPOSmulti 44 A Cold-Plate Power Supply Module
- 8BVP0880HC00.000-1 – ACOPOSmulti 88 A Cold-Plate Power Supply Module
- 8BVI0014HWS00.000-1 – ACOPOSmulti Inverter Module
- 8BVI0028HWS00.000-1 – ACOPOSmulti Inverter Module
- 8BVI0055HWS00.000-1 – ACOPOSmulti Inverter Module
- 8BVI0110HWS00.000-1 – ACOPOSmulti Inverter Module
- 8B0C0320HWS00.000-1 – ACOPOSmulti Capacitor Module
- 8B0C0640HWS00.000-1 – ACOPOSmulti Capacitor Module
- 8BAC0120.000-1 – ACOPOSmulti EnDat 2.1 Interface Module
- 8BXF001.0000-00 – ACOPOSmulti Replacement Fan Module
- 8BZVP044000.000-1A – ACOPOSmulti Screw-Clamp Terminal Block Set
- 8BXB000.0000-00 – ACOPOSmulti Encoder Buffering Accessory Set