Product Description
The HEIDENHAIN UV 130 (ID 324 998-03) is a non-regenerative power supply unit designed for HEIDENHAIN modular inverter systems used in CNC machine tools. It supplies the DC-link voltage and provides power for the control logic and connected UM 1xx power modules. With a rated DC-link output power of 30 kW, the unit supports multi-axis and spindle drive configurations when correctly matched with the inverter modules and braking components. The UV 130 operates from a three-phase 400 V AC supply and provides approximately 565 V DC on the DC link. During motor deceleration, regenerated energy is dissipated through a compatible braking resistor rather than returned to the mains. This unit is identified by part number 324 998-03 and belongs to the HEIDENHAIN UV 130 power supply family. It is intended for compatible legacy CNC drive systems, and replacement selection should be based on the complete part number, revision, inverter configuration, and machine wiring.

📋 Technical Specifications
- Brand: HEIDENHAIN
- Model: UV 130
- Part Number: 324 998-03
- Product Name: Inverter Power Supply Unit
- Product Series: HEIDENHAIN Modular Inverter System
- Product Type: Non-regenerative power supply unit
- Rated DC-Link Power: 30 kW
- Peak Power (S6-40%): 40 kW
- Short-Time Peak Power: Up to 50 kW for 0.2 seconds, according to the applicable technical documentation
- Input Power Supply: 3 × 400 V AC ±10%
- Input Frequency: 50–60 Hz
- DC-Link Voltage: Approximately 565 V DC at 400 V AC input
- Approximate Power Loss: 140 W
- Protection Rating: IP20
- Approximate Weight: 9.8 kg
- Module Width: 150 mm
- Place of Manufacture: Germany
- Country of Origin: Germany (confirm against the individual nameplate)
- Product Status: Legacy product; verify current manufacturer support
- Dimensions: Overall dimensions should be checked against the installation drawing
- Cooling: Internal heat dissipation
- System Function: Supplies the DC link and electronics power for compatible HEIDENHAIN control and power modules
- Braking Energy Management: Requires a compatible braking resistor arrangement
- Identification Revision: 324 998-03
🔧 Installation and Operating Procedures
- Preparation and inspection
- Confirm the nameplate reads UV 130 and ID 324 998-03.
- Inspect the housing, mounting plate, power terminals, ribbon-cable connectors, and protective covers.
- Check for signs of overheating, corrosion, loose connections, or physical damage.
- Verify that the existing CNC system uses a compatible HEIDENHAIN modular inverter configuration.
- Review the system wiring diagram and confirm the required braking resistor and UM 1xx power modules.
- Installation
- Switch off the CNC machine and isolate the incoming three-phase power supply.
- Follow the manufacturer’s DC-link discharge procedure and verify that hazardous voltage has fallen to a safe level before handling connections.
- Mount the UV 130 in the designated inverter-system position.
- Connect the three-phase supply, protective earth, DC-link connections, and control-system connections according to the original wiring diagram.
- Connect the unit bus and ribbon cables to the designated compatible modules.
- Verify the braking resistor wiring and thermal protection arrangement.
- Check cable routing, terminal tightness, grounding, and protective covers before energizing.
- Power-on and commissioning
- Confirm that all power and control connections are correctly installed.
- Check that the incoming supply is within the specified voltage and frequency range.
- Restore power according to the CNC manufacturer’s startup sequence.
- Check the READY indication and inspect the diagnostic indicators.
- Confirm that the connected control logic and power modules receive the required supply.
- Do not enable servo operation until the DC-link and safety circuits have passed the required checks.
- Normal operation
- Monitor the READY status and DC-link condition during machine operation.
- Confirm that connected axis and spindle modules respond correctly to control commands.
- Observe the braking resistor and its ventilation arrangement during deceleration.
- Check for abnormal noise, excessive temperature, or recurring voltage and current alarms.
- Stop operation if the unit reports a DC-link overvoltage, undervoltage, overcurrent, or temperature fault.
- Parameter configuration
- The UV 130 is primarily a power supply unit; system-level configuration is handled through the compatible HEIDENHAIN CNC control and inverter system.
- Verify the connected power modules, control logic, DC-link arrangement, and braking resistor specifications.
- Check the complete system’s 15 V, 24 V, and 5 V auxiliary supply requirements where applicable.
- Do not change wiring or substitute braking components based only on nominal power ratings.
- Save the machine configuration and commissioning records after successful testing.
- Shutdown
- Stop machining and bring all axes and the spindle to a controlled standstill.
- Disable servo operation using the machine’s normal shutdown sequence.
- Isolate the incoming power supply.
- Wait for the DC-link capacitors to discharge according to the manufacturer’s instructions.
- Verify the absence of hazardous voltage before maintenance or disconnection.
🛠️ Daily Maintenance
- Check the READY indicator and record any diagnostic or fault indications.
- Inspect power terminals, grounding connections, and cable covers.
- Keep the inverter cabinet clean and free from conductive dust, oil, and moisture.
- Check cabinet ventilation and verify that the unit is not exposed to excessive ambient temperature.
- Inspect the braking resistor and its wiring for overheating or insulation damage.
- Monitor DC-link voltage behavior during acceleration and deceleration.
- Check for unusual odors, discoloration, or signs of electrical arcing.
- Maintain backups of the CNC parameters and inverter-system configuration.
- Arrange periodic inspection by qualified personnel according to the machine manufacturer’s maintenance schedule.
⚠️ Troubleshooting and FAQ
Q1: The UV 130 does not show READY. What should be checked?
A: Check the three-phase input supply, protective earth, control connections, and diagnostic indicators. Confirm that the supply voltage is within the specified range and that no external safety circuit is preventing startup.
Q2: What does a DC-link undervoltage alarm indicate?
A: Possible causes include an input supply problem, a failed internal power component, excessive loading, or a fault in the DC-link circuit. Check the incoming supply and the connected inverter modules before replacing the unit.
Q3: What can cause a DC-link overvoltage alarm?
A: Excessive regenerative energy during deceleration, an incorrectly selected braking resistor, an open braking circuit, or a defective braking component can cause DC-link overvoltage. Check the complete braking arrangement against HEIDENHAIN specifications.
Q4: Can the UV 130 replace the UV 130D?
A: Do not assume direct interchangeability. The UV 130D has a different identification number and additional diagnostic features. Confirm the system architecture, auxiliary supply requirements, connector assignments, and manufacturer documentation before substitution.
Q5: Is the UV 130 a regenerative power supply?
A: No. The UV 130 is a non-regenerative power supply. Braking energy is dissipated through a compatible braking resistor instead of being returned to the electrical supply network.
Q6: Can this unit operate independently?
A: No. It is designed to work as part of a compatible HEIDENHAIN modular inverter system with the required control logic, power modules, cabling, and braking components.
🔒 Safety Precautions
- Installation and servicing must be performed by qualified industrial electrical or CNC service personnel.
- The unit operates with hazardous three-phase AC input and a high-voltage DC link.
- Isolate all power sources and follow the manufacturer’s lockout and discharge procedures before servicing.
- Never assume that the DC link is discharged immediately after switching off the supply.
- Verify the absence of hazardous voltage with an appropriately rated measuring instrument.
- Do not disconnect power or DC-link connections while energized.
- Use only compatible braking resistors and inverter modules.
- Maintain protective earth connections and all specified safety interlocks.
- Do not bypass safety circuits or operate the equipment with damaged covers.
🔑 Product Keywords
HEIDENHAIN UV 130, 324998-03, 324 998-03, UV130 Power Supply, HEIDENHAIN Inverter Power Supply, 30 kW Power Supply Unit, CNC Drive Power Supply, 565 V DC Link, Non-Regenerative Power Supply, HEIDENHAIN Modular Inverter, CNC Machine Tool Spare Parts, UM 1xx Power Module, Industrial Servo Drive System.
For industrial automation and CNC control products, visit: https://www.newplcdcs.com
🔄 15 Related HEIDENHAIN Models and Components
- HEIDENHAIN UV 130D – Non-regenerative power supply unit
- HEIDENHAIN UV 120 – Non-regenerative power supply unit
- HEIDENHAIN UVR 120D – Regenerative power supply unit
- HEIDENHAIN UVR 130D – Regenerative power supply unit
- HEIDENHAIN UV 140 – Non-regenerative power supply unit
- HEIDENHAIN UVR 140D – Regenerative power supply unit
- HEIDENHAIN UV 150 – Non-regenerative power supply unit
- HEIDENHAIN UVR 150D – Regenerative power supply unit
- HEIDENHAIN UVR 160D – Regenerative power supply unit
- HEIDENHAIN UVR 160DW – Regenerative power supply unit
- HEIDENHAIN UM 111 – Inverter power module
- HEIDENHAIN UM 111B – Inverter power module
- HEIDENHAIN UM 112 – Inverter power module
- HEIDENHAIN PW 210 – Braking resistor
- HEIDENHAIN PW 110 – Braking resistor with fan
Note: These are related HEIDENHAIN inverter-system products and components, not guaranteed direct replacements for the UV 130. Confirm rated power, supply voltage, DC-link compatibility, auxiliary supply capacity, braking arrangement, and connector configuration before selecting an alternative.