Product Description
The Rexroth Indramat DDS02.2-A100-BE45-01-FW is a digital AC servo drive controller from the DDS02.2 modular drive system. Designed for industrial motion-control applications, it provides a 100 A rated current and operates from a 300 V DC bus supplied by a compatible Indramat power supply unit. Its SERCOS communication interface supports integration with compatible motion-control systems, while digital servo and resolver feedback support motor speed and position control. The A-type cooling configuration uses external cabinet air for thermal management. This module is suitable for CNC machinery, automated production equipment, and multi-axis industrial drive systems. Exact compatibility depends on the installed command communication module, motor feedback, firmware, and system configuration.

Key Product Parameters
- Brand: Bosch Rexroth / Indramat
- Model: DDS02.2-A100-BE45-01-FW
- Material Number: R911267846
- Series: DDS02.2 Digital Drive Controller
- Product Name: Digital AC Servo Drive Module
- Rated Current: 100 A
- DC Bus Voltage: 300 V DC ±15%
- Cooling Method: External air cooling
- Communication Interface: SERCOS
- Motor Feedback: Digital servo feedback and resolver feedback
- Protection Rating: IP20
- Operating Temperature: 0 to 45°C
- Storage Temperature: -30 to +85°C
- Maximum Relative Humidity: 95%, non-condensing
- Weight: Approximately 11 kg
- Dimensions: Refer to the DDS02.2 installation dimensional drawing
- Product Status: New Original Packaging
- Country of Origin: Not confirmed; check the product nameplate
- Power Requirements: Compatible Indramat DC bus supply; separate 24 V control supply requirements must be checked against the system documentation
- Firmware: FW designation indicates firmware is ordered as a separate item; verify the installed firmware module and version
- Discontinued Status: Legacy product; confirm current support and availability with Rexroth
Installation and Operating Procedures
- Preparation
- Confirm the complete model code and material number R911267846.
- Verify compatibility with the existing Indramat power supply, drive rack, motor, and command interface.
- Check the motor nameplate, feedback device, power cable, and temperature-monitoring connections.
- Inspect the module, connector pins, cooling surfaces, and packaging for damage.
- Confirm that the correct firmware and parameter backup are available.
- Installation
- Isolate the drive system and follow the machine lockout procedure.
- Wait for the DC bus to discharge and verify that hazardous voltage is absent.
- Install the module in the designated DDS drive system mounting position.
- Ensure that the external air-cooling path is correctly arranged and unobstructed.
- Connect the DC bus, motor power, protective earth, feedback, and communication connections according to the official wiring diagram.
- Check connector orientation, cable shielding, and grounding before energizing.
- Power-On Checks
- Verify DC bus voltage and the condition of the compatible power supply.
- Check the 24 V control supply and all required auxiliary connections.
- Confirm that the SERCOS fiber-optic connections are correctly installed.
- Inspect motor and feedback wiring for shorts, loose terminals, or incorrect pin assignments.
- Energize the system according to the manufacturer’s commissioning sequence.
- Configuration
- Confirm the installed command communication module and firmware version.
- Configure the SERCOS communication parameters to match the motion controller.
- Select the correct motor data and feedback configuration.
- Set current limits, operating limits, acceleration, deceleration, and protection parameters according to the motor and machine requirements.
- Verify axis addressing and communication status before enabling motion.
- Normal Operation
- Perform an initial low-speed movement test.
- Check motor direction, feedback signals, current, and operating temperature.
- Test enable, stop, interlock, and fault-reset functions.
- Confirm that the drive communicates correctly with the higher-level CNC or PLC controller.
- Record the final parameter set and commissioning results.
- Shutdown
- Stop the axis using the approved machine shutdown sequence.
- Disable the drive and isolate the power supply.
- Allow the DC bus to discharge fully.
- Verify the absence of hazardous voltage before removing connectors or servicing the module.
Daily Maintenance
- Inspect the module for abnormal temperature, noise, or visible damage.
- Keep the external cooling air path clean and unobstructed.
- Check the cabinet ventilation system and air filters.
- Inspect power, motor, feedback, and fiber-optic connections.
- Monitor drive fault history and SERCOS communication status.
- Check for loose connections, damaged insulation, or signs of overheating.
- Maintain backups of drive parameters and firmware information.
- Record operating abnormalities and corrective maintenance actions.
Troubleshooting
- Drive does not power up: Check the DC bus supply, auxiliary control voltage, fuses, and system connections.
- SERCOS communication failure: Inspect fiber-optic cables, connectors, ring topology, and controller configuration.
- Motor does not move: Check drive enable conditions, interlocks, motor wiring, and command signals.
- Feedback error: Verify the encoder or resolver type, feedback cable, connector pinout, and configured motor data.
- Overcurrent fault: Inspect motor cables, motor insulation, mechanical load, and current-limit settings.
- Overtemperature fault: Check external cooling airflow, cabinet temperature, and cooling-system operation.
- DC bus fault: Measure the DC bus voltage and inspect the compatible power supply and bus connections.
- Firmware or configuration error: Verify the firmware module, drive configuration, and compatibility with the machine controller.
Safety Precautions
- Installation and maintenance must be performed by qualified industrial electrical personnel.
- Always isolate the power supply before working on the drive.
- Wait for DC bus capacitors to discharge and verify the voltage with an appropriate measuring instrument.
- Never connect or disconnect motor, feedback, or power cables while the system is energized.
- Use the specified protective grounding and cable shielding methods.
- Do not exceed the rated current or permitted operating temperature.
- Ensure that the external cooling airflow meets the manufacturer’s requirements.
- Use only compatible firmware, command modules, and motor feedback configurations.
- Follow the official Rexroth Indramat DDS02.2 operating and installation documentation.
Product Keywords
Rexroth Indramat DDS02.2-A100-BE45-01-FW, R911267846, DDS02.2 servo drive, Bosch Rexroth drive controller, 100 A AC servo module, Indramat digital drive, SERCOS servo controller, 300 V DC bus drive, external air-cooled servo drive, CNC motion control, industrial automation spare parts, Rexroth DDS drive module.
For more industrial automation products and replacement components, visit www.newplcdcs.com.
15 Related / Recommended Models
The following are related Indramat DDS drive controllers and system components for comparison and spare-parts research. They are not confirmed direct replacements for DDS02.2-A100-BE45-01-FW.
- DDS02.2-A100-BE06-01-FW – 100 A DDS drive controller
- DDS02.2-A100-BE11-01-FW – 100 A DDS drive controller
- DDS02.2-A100-BE12-01-FW – 100 A DDS drive controller
- DDS02.2-A100-BE23-01-FW – 100 A DDS drive controller
- DDS02.2-A100-BE32-01-FW – 100 A DDS drive controller
- DDS02.2-A100-BE37-01-FW – 100 A DDS drive controller
- DDS02.2-A100-BE43-01-FW – 100 A DDS drive controller
- DDS02.2-A100-BE43-02-FW – 100 A DDS drive controller
- DDS02.2-A100-BE76-01-FW – 100 A DDS drive controller
- DDS02.2-A200-BE11-02-FW – 200 A DDS drive controller
- DDS02.2-A200-BE12-01-FW – 200 A DDS drive controller
- DDS02.2-W100-BE45-01-FW – 100 A DDS drive controller with a different cooling configuration
- DDS02.2-W200-BE45-01-FW – 200 A DDS drive controller
- DKC01.1 – Indramat ECODRIVE drive family
- HVR03.1 – Indramat DIAX04 power supply family