Product Description
The B&R 8B0P0440HW00.000-1 is a passive, high-voltage ACOPOSmulti power supply module designed for wall mounting in industrial servo drive systems. It provides a DC bus supply for compatible ACOPOSmulti drive modules and supports a wide three-phase input voltage range. The module is rated for 44 A and features an integrated connection for an external braking resistor. It is intended for coordinated multi-axis motion control applications where several servo drives share a common DC bus. Installation requires the specified terminal block set and must follow B&R’s electrical, grounding, cooling, and system configuration requirements.

Product Datasheet
- Brand: B&R Automation
- Product Series: ACOPOSmulti
- Model: 8B0P0440HW00.000-1
- Product Type: Passive power supply module
- Rated Current: 44 A
- Mounting Type: Wall mounting
- Mains Input Voltage: 3 × 380 to 3 × 500 VAC, ±10%
- Input Frequency: 50/60 Hz, ±4%
- Nominal DC Bus Voltage: 537 to 707 VDC
- Continuous Power: 16 kW
- Peak Power Output: 48 kW
- Maximum Installed Load: 30.4 kVA
- Power Dissipation at Continuous Power: Approximately 300 W
- Inrush Current at 400 VAC: 10 A
- External Braking Resistor: Connection provided
- Network Configuration: TT, TN-S, TN-C-S
- Dimensions: 317 × 106.5 × 263 mm (H × W × D)
- Weight: Approximately 6.1 kg
- Protection and Certification: cULus, CE, UKCA, and KC listed by manufacturer
- Condition: Subject to seller confirmation
- Country of Origin: Not verified
- Product Status: Confirm current availability with B&R
Operating Guidelines and Usage
- Confirm that the module’s complete part number matches the electrical design and the installed ACOPOSmulti system.
- Verify that the incoming three-phase supply is within the specified voltage and frequency limits.
- Install the module in the specified wall-mounting orientation with sufficient clearance for cooling and maintenance.
- Use the required terminal block set, B&R part number 8BZ0P044000.000-1A, and verify that all terminal components are present.
- Connect protective earth and cable shields according to the manufacturer’s installation instructions.
- Confirm that the connected drive modules, DC bus configuration, braking resistor, and protective devices are compatible with the system design.
- Do not exceed the module’s continuous power, current, or DC bus capacitance limits.
Power-On and Power-Off Sequence
Power-On
- Inspect the module, mounting hardware, terminals, and wiring for damage or loose connections.
- Verify protective earth continuity and confirm that the input supply is correctly rated.
- Check the DC bus connections and external braking resistor wiring, if used.
- Confirm that all connected drive modules are correctly installed and that the system is ready for energization.
- Apply the three-phase supply in accordance with the machine manufacturer’s commissioning procedure.
- Check system indications and controller diagnostics before enabling the servo axes.
Power-Off
- Stop machine motion and disable all servo axes through the control system.
- Remove the mains supply using the approved isolation procedure.
- Allow the DC bus to discharge for the period specified in the manufacturer’s manual.
- Verify the DC bus voltage with an appropriately rated measuring instrument before touching electrical connections.
- Apply lockout/tagout procedures before maintenance or wiring work.
Normal Operating Procedure
- Monitor the ACOPOSmulti system for power supply, DC bus, and drive-related diagnostic messages.
- Keep the module’s cooling surfaces and ventilation paths free of dust and obstructions.
- Ensure that the incoming supply remains within the permitted voltage range.
- Check the load distribution across connected drive modules against the system design.
- Monitor braking resistor operation and inspect its wiring and mounting where applicable.
- Record operating alarms, maintenance actions, and changes to the drive configuration.
Parameter Settings and Modification
The 8B0P0440HW00.000-1 is a passive power supply module. It does not function as an independently programmable motion controller. System-level configuration and diagnostics are handled through the compatible ACOPOSmulti drive and controller environment.
Before modifying the installation or drive configuration:
- Verify the ACOPOSmulti hardware configuration and applicable Automation Studio version.
- Confirm DC bus capacitance and power requirements for all connected modules.
- Check the braking resistor type, resistance, and power rating against the application requirements.
- Verify mains protection and cable sizing against B&R documentation and applicable electrical codes.
- Back up the machine configuration before making system-level changes.
Maintenance and Troubleshooting
Preventive Maintenance
- Inspect power terminals and protective earth connections during scheduled shutdowns.
- Check for discoloration, overheating, dust accumulation, and signs of electrical damage.
- Inspect cooling conditions and verify that the required airflow is maintained.
- Check braking resistor connections and external wiring where installed.
- Review system alarms and operating records for recurring power-related faults.
Troubleshooting
- No DC bus voltage: Check the three-phase input supply, upstream protection, wiring, and module status.
- DC bus undervoltage: Verify mains voltage, input connections, and total connected load.
- Unexpected power interruptions: Inspect upstream fuses or circuit breakers, terminal tightness, and supply stability.
- Overtemperature indications: Check ambient conditions, ventilation, mounting clearance, and cooling paths.
- Braking-related faults: Verify the external braking resistor specification, wiring, and connection integrity.
Only qualified electrical personnel should perform testing or repairs. Internal component-level repair should be referred to an authorized service provider.
Safety Precautions
- This module operates with hazardous three-phase voltage and a high-voltage DC bus.
- Disconnect and isolate all power sources before installation, inspection, or maintenance.
- Wait for the DC bus to discharge and independently verify that voltage is at a safe level before handling terminals.
- Use appropriately rated fuses, circuit breakers, conductors, and measuring instruments.
- Connect protective earth before energizing the equipment.
- Do not modify the module, bypass protective devices, or use unapproved braking resistors.
- Follow the latest B&R ACOPOSmulti user manual and the machine manufacturer’s safety procedures.
Recommended Related B&R Models
The following models are related ACOPOSmulti power, drive, and system components. They are not automatically direct replacements for the 8B0P0440HW00.000-1; verify electrical ratings, mounting type, and system compatibility before ordering.
- 8B0P0220HW00.000-1 – ACOPOSmulti 22 A passive power supply module
- 8B0P0440HC00.000-1 – ACOPOSmulti 44 A passive power supply module, cold-plate/feed-through mounting
- 8B0P0220HC00.000-1 – ACOPOSmulti 22 A passive power supply module, cold-plate/feed-through mounting
- 8B0C0320HW00.000-1 – ACOPOSmulti capacitor module
- 8B0C0160HW00.000-1 – ACOPOSmulti capacitor module
- 8BVI0055HCS0.000-1 – ACOPOSmulti inverter module
- 8BVI0220HWS0.000-1 – ACOPOSmulti inverter module
- 8BVI0330HWS0.000-1 – ACOPOSmulti inverter module
- 8BVE系列 ACOPOSmulti inverter modules – Drive modules for multi-axis systems
- 8B0K series ACOPOSmulti modules – Compatible system components; verify the exact type
- 8BXF001.0000-00 – ACOPOSmulti replacement fan module
- 8BXS003.0000-00 – ACOPOSmulti fuse set
- 8B0W0045H000.000-1 – 450 W external braking resistor, IP20
- 8B0W0079H000.000-1 – 790 W external braking resistor, IP20
- 8BZ0P044000.000-1A – ACOPOSmulti screw-clamp terminal block set