The Siemens SIMOTICS S-1FK7 1FK7083-2AC71-1RG0 is a permanent-magnet synchronous servo motor designed for precision motion control in industrial automation systems. With a rated power of approximately 2.6 kW, a rated speed of 2,000 rpm, and a rated torque of 12.5 Nm, it is suitable for machine tools, packaging machinery, material handling, and other applications requiring controlled speed and positioning. This motor features natural cooling, an IM B5 flange mounting arrangement, a smooth shaft, and an absolute encoder with DRIVE-CLiQ interface for feedback integration with compatible Siemens drive systems. The specified version is supplied without a holding brake. Its motor feedback, power connector orientation, and mechanical configuration should be checked against the existing drive system before installation. Verify the complete order number and nameplate data to ensure compatibility with the SINAMICS drive, motor module, and machine application.

📋 Product Specifications
| Parameter | Description |
|---|---|
| Brand | Siemens |
| Product Family | SIMOTICS S-1FK7 |
| Model | 1FK7083-2AC71-1RG0 |
| Product Type | AC Permanent-Magnet Synchronous Servo Motor |
| Rated Power | 2.6 kW |
| Rated Speed | 2,000 rpm |
| Rated Torque (100 K) | 12.5 Nm |
| Static Torque (100 K) | 16 Nm |
| Rated Current | 6.3 A |
| Maximum Permissible Mechanical Speed | 6,000 rpm |
| Maximum Torque | 50 Nm |
| Maximum Current | 27.5 A |
| Number of Poles | 8 |
| Torque Constant | 2.13 Nm/A |
| Cooling Method | Natural cooling |
| Mounting Arrangement | IM B5 (IM V1 / IM V3) |
| Shaft Design | Smooth shaft |
| Encoder | Absolute encoder, DRIVE-CLiQ interface |
| Holding Brake | Without holding brake |
| Protection Rating | IP64 |
| Shaft Height | 80 mm |
| Temperature Monitoring | Verify exact sensor configuration by nameplate |
| Motor Weight | Approx. 15.6 kg |
| Dimensions | Verify against the Siemens mechanical drawing |
| Place of Manufacture | Not confirmed |
| Country of Origin | Germany reported by supplier; verify nameplate |
| Product Status | SIMOTICS S-1FK7 product family |
| Discontinued | Exact lifecycle status not confirmed |
| Compatible Drive System | Compatible Siemens SINAMICS drive configuration |
⚙️ Installation and Operation
- Installation: Disconnect the drive system from the power supply. Secure the motor using the specified flange mounting arrangement. Check shaft alignment, coupling dimensions, mounting bolts, grounding, and mechanical clearances. Ensure the motor is installed in an environment suitable for its IP64 protection rating.
- Power-On: Verify the motor power cable, DRIVE-CLiQ feedback connection, and protective grounding. Confirm that the connected SINAMICS drive and motor module support the exact motor configuration before enabling the drive.
- Normal Operation: Monitor motor speed, torque demand, current, temperature, and encoder feedback. Check for abnormal vibration, noise, or excessive heating during operation.
- Parameter Configuration: Select the correct Siemens motor data in the drive configuration. Verify encoder identification, feedback settings, current limits, speed limits, and control parameters. Back up the existing drive configuration before changing motor data.
- Power-Off: Stop the machine using its approved shutdown sequence, disable the drive, isolate the power supply, and wait for the DC link to discharge before disconnecting motor cables.
🔧 Maintenance and Troubleshooting
- Motor fails to start: Check the drive enable signal, power connections, motor configuration, and drive fault messages.
- Encoder communication error: Inspect the DRIVE-CLiQ cable, connectors, feedback configuration, and drive compatibility.
- Abnormal motor temperature: Check mechanical loading, ventilation clearance, ambient temperature, and operating current.
- Excessive vibration: Inspect motor mounting, shaft alignment, coupling condition, and connected machine bearings.
- Unexpected speed or torque: Verify motor identification, encoder feedback, control parameters, and drive limits.
- Insulation or grounding alarm: Inspect motor cables, protective grounding, and winding insulation using approved procedures.
🛡️ Safety Precautions
- Installation and commissioning must be performed by qualified electrical and automation personnel.
- Isolate the drive supply and verify the absence of hazardous voltage before servicing.
- Permanent-magnet motors can generate voltage when the shaft is rotated externally.
- Do not disconnect power or feedback connectors while the drive is energized.
- Confirm shaft alignment, motor mounting, cable ratings, and encoder compatibility before operation.
- This exact version is specified without a holding brake; do not rely on the motor to hold a vertical or gravity-loaded axis when power is removed.
- Verify the machine’s independent braking and safety arrangements before commissioning.
🔗 Related Siemens Models
The following are related Siemens SIMOTICS S-1FK7 servo motor models. They may differ in speed, torque, encoder, shaft design, or holding-brake configuration and are not automatically interchangeable.
- Siemens 1FK7083-2AC71-1RG2
- Siemens 1FK7083-2AC71-1RH0
- Siemens 1FK7083-2AC71-1RH1
- Siemens 1FK7083-2AC71-1RB0
- Siemens 1FK7083-2AC71-1CG0
- Siemens 1FK7083-2AF71-1CG0
- Siemens 1FK7083-2AF71-1RB0
- Siemens 1FK7081-3BF71-1CH0
- Siemens 1FK7081-3BF71-1CH1
- Siemens 1FK7083-2AC74-1SA1
- Siemens 1FK7084-2AC71-1RG0
- Siemens 1FK7101-5AF71-1RG0
- Siemens 1FK7101-5AF71-1RH0
- Siemens 1FK7103-5AF71-1CG0
- Siemens 1FK7105-5AF71-1RG0